Laserfiche WebLink
NEW COMPACTED FILL - <br />COMPETENT MATERIAL - <br />CUT/FILL CONTACT TO BE <br />SHOWN ON "AS-BUILT <br />NATURAL GRADE -7 <br />L <br />CUT/FILL CONTACT SHOWN / <br />/-- ON GRADING PLAN - / <br />.-REMOVE.UNSUITABLE N*f--7 4' TYP. <br />10'TYP./- 1 // . . 1 <br />*92>y>YES»2>2>22 <br />CUT SLOPE ----20 <br />- - .4 1 <br />9' MIN./ <br />1 BENCHING DIMENSIONS IN ACCORDANCE <br />WITH PLAN OR AS RECOMMENDED <br />BY THE GEOTECHNICAL ENGINEER <br />- MINIMUM 1' TILT BACK <br />OR 2% SLOPE <br />(WHICHEVER IS GREATER) <br />CUT SLOPE TO BE CONSTRUCTED <br />PRIOR TO PLACEMENT OF FILL <br />BEDROCK OR APPROVED <br />COMPETENT MATERIAL <br />L- <br />KEYWAY IN COMPETENT MATERIAL <br />MINIMUM WIDTH OF 15 FEET OR AS <br />RECOMMENDED BY THE GEOTECHNICAL <br />ENGINEER. KEYWAY MAY NOT BE <br />REQUIRED IF FILL SLOPE IS LESS THAN 5 <br />FEET IN HEIGHT AS RECOMMENDED BY <br />THE GEOTECHNICAL ENGINEER. <br />FILL ABOVE CUT SLOPE DETAIL <br />GRADING GUIDE SPECIFICATIONS <br />NOT TO SCALE 4 <br />DRAWN. JAS <br />CHKD: GKM <br />PLATE D-2 <br />2->Z