Laserfiche WebLink
SUMMARY <br />OF <br />ONE ENETRATION EST DATA <br />1. INTRODUCTION <br />This report presents the results of a Cone Penetration Test (CPT) program carried out for the <br />project located at 2001 E. Dyer Road in Santa Ana, California. The work was performed by <br />Kehoe Testing & Engineering (KTE) on July 21-22 & 29, 2015. The scope of work was <br />performed as directed by Group Delta Consultants, Inc. personnel. <br />2. SUMMARY OF FIELD WORK <br />The fieldwork consisted of performing CPT soundings at 16 locations to determine the soil <br />lithology. Groundwater measurements and hole collapse depths provided in TABLE 2.1 are <br />for information only. The readings indicate the apparent depth to which the hole is open and <br />the apparent water level (if encountered) in the CPT probe hole at the time of measurement <br />upon completion of the CPT. KTE does not warranty the accuracy of the measurements and <br />the reported water levels may not represent the true or stabilized groundwater levels. <br />DEPTH OF <br />LOCATION CPT (ft)COMMENTS/NOTES: <br />C-1 54 Hole open to 23.0 ft (dry) <br />C-2 45 Refusal, hole open to 20.0 ft (dry) <br />C-3 54 Hole open to 22.0 ft (dry) <br />Cdt 54 Hole open to 22.5 ft (dry) <br />C-5 50 Hole open to 8.0 ft (dry) <br />C-6 70 Groundwater @ 14.5 ft <br />C-7 50 Groundwater @ 8.5 ft <br />C-8 50 Groundwater @ 19.0 ft <br />C-9 50 Groundwater @ 15.5 ft <br />C-10 50 Groundwater @ 27.5 ft <br />C-11 125 Hole open to 12.0 ft (dry) <br />C-12 3 Refusal, hole caved @ 3.0 ft (dry) <br />C-12A 120 Groundwater @ 17.0 ft