My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1901-1919 N Fairview St - Soils Report
PBA
>
Building
>
Soils Reports
>
F
>
Fairview St
>
1901 N Fairview St
>
1901-1919 N Fairview St - Soils Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2026 1:07:26 PM
Creation date
6/23/2022 1:32:37 PM
Metadata
Fields
Template:
Soils Report
Full Address
1901 N Fairview St
1902 N Fairview St
1903 N Fairview St
1904 N Fairview St
1905 N Fairview St
1906 N Fairview St
1907 N Fairview St
1908 N Fairview St
1909 N Fairview St
1910 N Fairview St
1911 N Fairview St
1912 N Fairview St
1913 N Fairview St
1914 N Fairview St
1915 N Fairview St
1916 N Fairview St
1917 N Fairview St
1918 N Fairview St
1919 N Fairview St
Street Number
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
Street Direction
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Street Name
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Fairview
Street Suffix
St
St
St
St
St
St
St
St
St
St
St
St
St
St
St
St
St
St
St
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
603284-001 <br />adjacent foundations after reviewing details of the planned basement walls in <br />relation to existing foundations. <br />Backfills for retaining walls should be compacted to a minimum of 90 percent <br />relative compaction (based on ASTM Test Method D1557). During construction <br />of retaining walls, the backcut should be made in accordance with the <br />requirements of Cal/OSHA Construction Safety Orders.Relatively light <br />construction equipment should be used to backfill retaining walls. We also <br />recommend using at-rest pressures for design of walls supporting settlement- <br />sensitive structures. <br />Earth pressures used in the design of the walls should be indicated on the <br />retaining wall plans. All retaining wall designs and plans should be reviewed by <br />the project geotechnical consultant to confirm that the appropriate soil <br />parameters are used. <br />5.5 Seismic Design Parameters <br />Seismic design values based on the mapped acceleration parameters and the <br />site-specific procedure per the 2010 CBC (based on ASCE/SEI 7-05) were <br />developed. Due to the liquefaction hazard at the site, the site type is classified <br />as "F", which would typically trigger a site-response analysis. However, based <br />on our discussions with the project structural engineer, the proposed buildings <br />are deemed short-period structures with fundamental periods of about 0.5 <br />second or less. Accordingly, the exception under Section 20.3.1 was used to <br />develop site-specific seismic parameters. <br />The justification for the short period exemption is that during an earthquake, the <br />soil profile will respond differently before and after the onset of liquefaction. <br />Ground motions may be considerably higher for short-period structures before <br />the onset of liquefaction. Before the onset of liquefaction, ground motions will be <br />characteristic of the behavior modeled by Site Classes for non-liquefied soils. <br />For non-liquefied soils, it is expected that the short period spectral accelerations <br />will be relatively high. After the onset of liquefaction, the soil will become much <br />softer and result in a reduction of the short period ground motions and spectral <br />accelerations. The longer period spectral response, however, may increase <br />dramatically in terms of greater displacements. This approach is believed to be <br />conservative for determining the design base shear for short period (T<0.5 <br />-25- <br />Leighton