Laserfiche WebLink
Urban Testing & Inspections, Inc. <br />22138 South Vermont Ave., #G <br />Torrance, CA 90502 <br />Ph: 310-320-0482 <br />1/9.,4,146 :9,294.k..P'/t,1.--, - 9,·Ae., 4 'A'lf :hi5%194* impiR1,2-:er::2--' r . 7;1116:11@219=:.9, =46 -41'. @, 1.4 ' 1, <br />11 21 2 1 <br />Concrete Radiography <br />Daily Report <br />All inspections are based on a 4 hour minimum basis portal to portal. If technician is called <br />to a project and no work performed, a 4 hour minimum charge plus travel is applied. <br />Project #:1204-12480 Service Date:07-25-2018 <br />Project Name: 888 N. Main St. <br />Address:888 N. Main St, Santa Ana CA <br />Contractor:Caribou Industries Source/ Curies: Ir-192 / 42.9 Curies <br />Technician Comments: Arrived onsite to perform radiography on 3 locations at south side brick wall at mezzanine <br />level. Due to access not being available from both sides, information was obtained with <br />GPR/Cover Meter. GPR confirmed presence of horizontal and vertical rebar along with <br />with depth estimates ranging from 5 to 5 1/2". No reliable bar sizing information could be <br />obtained. See attached photograph page for details. <br />Note: Sample of Lightweight Concrete at mezzanine roof was taken for dry density testing <br />Project Notes: <br />• Contractor is responsible for maintaining all lines drawn (test results) on concrete and masonry. <br />Indications detected with Radiography are marked directly on scanning surface or on IRC Target Sticker using a uniform color code <br />as follows: BLACK for Rebar, BLUE for Conduit, and RED for Post Tension Cables. <br />If indications physically marked on test area(s) by the technician are in conflict with the specified layout for saw cut, drilling and/or <br />coring operations, it is recommended that written approval is obtained from authorized client representative prior to <br />, commencement of any saw cut, drilling and/or coring operations. <br />If rebar size estimation is performed, results are subject to a tolerance of +A 1 bar diameter. <br />If IRC TARGET STICKER is placed on concrete. Contractor is responsible to ensure cutting/coring operations are performed within <br />the target sticker area. If client wishes to cut/core outside of sticker area, additional X-Ray shots shall be required. <br />Signature below verifies technician(s) time onsite and services performed as per customer request. <br />Please refer to Photograph Page(s) for details. <br />DO NOT CUT, CORE, OR DRILL WITHIN 2" OF ANY MARKED INDICATIONS. <br />Technicians:D. Chick, S. Sequeira <br />Time In: 07:00 am Time Out: 11:00 am Travel Time:.5 Mileage: 12 Film Qty: 0 <br />Total Time (Incl. Drive Time) ST:4 OT:DT:Film Size: <br />Technician Signature Client Signature <br />Daniel Chick Eddie Narvaez <br />Technician Name Client Name <br />Continued on Next Page <br />Test Results provided by Urban Testing & Inspections, Inc. are given in good faith and are usually accurate. However, in the unlikely event that such Information proves to be <br />inaccurate, the extent of liability assumed by Urban Testing & Inspections, Inc., if any, is limited to the amount billed for labor and materials on the day that information <br />provided was alleged to have been Inaccurate. Please Note: Certain low-density materials such as PVC, -smurf tube- and plastics in general may not be located accurately, if <br />at all, using any inspection method.