157 of 234 <br />3033 S. Harbor Blvd. <br />Santa Ana, CA 92704 <br />Phone: 714-427-0501 <br />Fax: 714-427-0502 <br />www.inspection-resources.com <br />- il; <br />e-- INSPECTION* IVA RESOURCES <br />Experts In Nondestructive resting <br />GROUND PENETRATING RADAR TESTING FIELD REPORT- Concrete <br />Project Name <br />888 N. Main <br />Address Where Testing Occurred <br />888 N. Main, St, Santa Ana, CA <br />Contractor or Person Requesting Testing <br />Permit #:JurisdicUon: <br />Information Purposes Only <br />Name of Contact Person at Site <br />Date <br />06-29 thru 07-03-18 <br />IRC Project #: <br />1204-12480 <br />Technician(s)GPR Equipment Mfg and Model Number <br />Ryan Barkley Maia CX 11 <br />List Other Equipment Utilized (e.g. electromagneUc device) Mfg and Model <br />Elcometer <br />Type of Structure (e.g. multi story hotel; parking facility)General Site Conditions <br />Multi story building Free from obstructions <br />Technician Comments: <br />Excel file contains further reinforcing details <br />Antenna Frequency <br />1.6 GHz <br />Test Locations This Date <br />25 locations <br />Project Notes: <br />• Contractor is responsible for maintaining all lines drawn (test results) on concrete and masonry. <br />• Scans conducted near walls, cellings or borders will result in a 3" dead zone (area that cannot be scanned). <br />• Targets located with GPR are marked directly on scanning surface using BLACK, BLUE OR GREEN color markers. <br />• Live 50/60 Hz Electrical targets are marked in RED color markers or spray paint <br />• Un-energized / low voltage wires / data cables in plastic conduit cannot be easily detected with conventional GPR/Electromagnetic methods. <br />Client understands that detection using GPIVElectromagnetic methods are performed on a best effort basis and results are not guaranteed. If <br />GPR method proves to be having difficulty In resolving critical areas, X-Ray method is recommended. <br />• If GPR target lines physically marked on test area(s) by the technician are in conflict with the specified layout for saw cut, drilling and/or <br />caring operations, it is recommended that written approval is obtained from authorized client representative prior to commencement of any <br />saw cut, drilling and/or coring operations. <br />• Client understands that GPR interpretations do not differentiate between rebar, conduit, and/or PT cable. If client is requesting that these <br />elements must be positively identified, then X-Ray method shall be required. <br />• Rough surface conditions, obstructions in immediate GPR scanning area, high density wire mesh, weather proofing, or air gaps between <br />structural concrete/masonry layers may impede or prohibit radar penetration. If such condition(s) exist, alternative methods may be <br />necessary. <br />• If rebar size estimation is performed, results are subject to a tolerance of +/- 1 bar diameter. <br />• It is recommended that client stays 2" away from all targets marked. <br />• Signature below verifies techniclan(s) time onsite and services performed as per customer request <br />SEE ATTACHED PHOTOGRAPHS ON NEXT PAGE FOR DETAILS <br />Time In: 0730 Time Out: 1530 Total (Hrs): 24 Travel (Hrs): <br />Regular Time: 24 1.5X:2X: <br />9->25- <br />Tichnicion's Signaturr Clienl Signature <br />Continued on Next Page <br />Test Results provided by Inspection Resources, co are given in good faith and are usually accurate. However. in the unlikely event that such information proves to be <br />inatcurate, the extent of liability assumed by Inspecuon Resources, Co., if any, is limited to the amount billed for labor and materials on the day that information provided was <br />alleged to have been inaccurate. Please Note: Certain low-density materials such as PVC. 'smurf tube- and plastics in general may not be located accurately. if at all, using <br />any Inspection method.