22138 South Vermont Ave., #G <br />Torrance, CA 90502 <br />Ph: 310-320-0482 <br />Urban Testing & Inspections, Inc. <br /><33.9394 9.1 <br />1189 5,520; 3 <br />9 e'J G i i <br />%39....C , <br />i 1 I '111.-,;'. , 0, <br />Ii-2, <br />GPR / Cover Meter Results <br />Project: 888 N. Main St. Santa Ana, CA <br />4/30/2018 - 05/03/2018 <br />Page 5 of 5 <br />Area Line <br />FL 3 Perimeter 13 - G 1/2 thru J 1/2 <br />13 thru 12 1/2 <br />13 thru 12 1/2 <br />H - 13 Column - Horizontal <br />- 13 Column - Vertical <br />13 - J 1/2 Small column - Horizontal <br />13 - J 1/2 Small Column - Vertical <br />FL 8 Perimeter G 1/2 thru J 1/2 <br />H. <br />H <br />Inches Between Vertical Bars <br />Start wall, 5, 9, 9, 9, 9, 6, 4, 12 (Girder A), 4, 9, 10, 10, 7, 7, 4, 10, 5, 1, 2, 7, 9, 7, 3, <br />12(Girder B). 3.9.6.7. 11. 5. 12. End at wall <br />Start Beam, 8, 14, 20, stop <br />Start Beam 6,4,5,5,5,4,5,6,7,6,8, end wall <br />Start floor 6, 5, 6, 4, 2, 10, 10, 6, 18, stop <br />Start edge, 3, 7, 12, 3, end <br />Start floor, 17, 13, 13, 18, stop <br />Start edge, 3,5, edge <br />Start framing, 2, 4, 9, 8, 11, 10, 7, 1, Girder B, 5, 5, 8, 9, 8, 12, 8, 6, 4, Unable to <br />H-13 thru 12 1/2 <br />J - 13 thru 12 1/2 <br />- 13 Column - Horizontal <br />H - 13 Column - Vertical <br />13 - J 1/2 Small column - Horizontal <br />13 - J 1/2 Small Column - Vertical <br />1st Floor core 'N - 7 Column <br />C - 8 Core Column <br />6th Floor core F - 9 Core Column <br />8th Floor core F - 9 Core Column <br />10th Floor core F - 9 Core Column <br />NOTES: <br />GPR DETECTED 3 TARGETS IN BOTTOM OF BEAMS <br />GPR DETECTED 2 TARGETS IN BOTTOM OF GIRDERS <br />Girders = 20" thickness <br />12" thickness <br />H <br />scan further <br />Start Beam, 4, 7, 19, 18, stop <br />Start Beam, 6,6,6,8,5,7,5,7,5,7, stop at wall <br />Start Floor, 6, 6, 7, 5, 8, 12, 15, 17, end <br />Start edge, 4, 6, 12, 3, end <br />Start Floor, 27, 4, 2, 12, 18, end <br />Start edge, 2,5,3, end <br />Horizontal Vertical <br />17" avg 4"avg <br />Horizontal Vertical <br />18" avg 4"avg <br />Horizontal Vertical <br />18" avg 5"avg <br />Horizontal Vertical <br />18" avg 7" avg <br />Horizontal Vertical <br />18" avg 7" avg <br /> Beams = <br />End of Report <br />Test Results provided by Urban Testing & Inspections, Inc are given in good faith and are usually accurate. However, in the unlikely event that such information proves to be <br />inaccurate, the extent of liability assumed by Urban Testing & Inspections, Inc, if any, is limited to the amount billed for labor and materials on the day that information provided <br />was alleged to have been inaccurate. Please Note: Certain low-density materials such as PVC, 'smurf tube' and plastics in general may not be located accurately. if at all, <br />using any inspection method