My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
888 N Main St - Soils Report
PBA
>
Building
>
Soils Reports
>
M
>
Main St
>
888 N Main St
>
888 N Main St - Soils Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2026 4:05:17 PM
Creation date
6/23/2022 1:33:29 PM
Metadata
Fields
Template:
Soils Report
Full Address
888 N Main St
Street Number
888
Street Direction
N
Street Name
Main
Street Suffix
St
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
244
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
10196597 <br />ECEIVT- <br />Thornton Tomas, i MAY 31 2018 morandum <br />City of Santa Ana <br />Re: Alternative Methods Executive Summary (progress) <br />Page 2 <br />visual condition assessment and field testing for rebar number, size and grade, and concrete <br />strength at limited locations. If a 'knowledge factor' K of 1.0 rather than 0.75 in Table 6-1 is <br />needed to justify performance levels 'c' and 'd' the field testing program will be expanded to <br />follow the spirit of the :comprehensive testing program' in ASCE 41-13 while taking advantage <br />of the repetitive framing patterns of the lateral load resisting system. Testing includes small- <br />diameter concrete cores, Ground Penetrating Radar (GPR) scans of concrete faces for rebar <br />below the surface, local concrete cover removal to calibrate GPR scan readings to actual bar <br />sizes, surface hardness testing of exposed bars to establish rebar grades (rather than cutting <br />out bar samples for tension testing), and limited X-ray scans where they have the potential <br />to provide significant additional information. <br />4. Site visits for ASCE 41-13 visual condition assessment showed a concrete structural system <br />in good condition, with no significant deterioration at the primary lateral load resisting <br />elements. <br />5. Foundation elements are not visible and will not be tested or probed. This is considered <br />acceptable because Target Building Performance Levels 'c' and 'd' at 50%/50 year Hazard <br />Level imply low seismic demands for which foundation demands will be small, of comparable <br />magnitude to those already experienced during its 50 year life to date. Subgrade conditions <br />based on recent soil investigations at nearby sites will be discussed for reviewer information. <br />6. 'Seismic base' is taken at the Ground Floor for computer modeling, with lateral restraint there. <br />Column continuity through the Ground Floor is modeled by one-story basement columns and <br />existing concrete infill walls between them. Significant Ground Floor lateral restraint is <br />provided by a continuous reinforced concrete slab tied to heavy perimeter basement walls, <br />and by infill walls between tower perimeter columns in the basement itself. For Target <br />Performance 'c' and 'd' this modeling approach is appropriate. <br />7. For alternative improvement models, only viscous diagonal dampers will be modeled as <br />nonlinear elements. All other elements are modeled as elastic (with stiffness modifiers). First <br />story tower perimeter columns will be modeled as linear, but being wrapped with FRP for <br />shear capacity greater than plastic demand Vp, they can have Demand Capacity Ratios <br />(DCRs) higher than 1.0 due to improved ductility after wrapping. <br />8. Response spectrum analysis (RSA) will be used for determining before- and after- <br />improvement performance. Spectrum modifications to reflect increased damping will follow <br />ASCE 41-13 recommendations. In addition, a limited number of realistic earthquake runs
The URL can be used to link to this page
Your browser does not support the video tag.