My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20163063 - Permit
PBA
>
Building
>
Permits
>
R
>
Rosewood Ave
>
514 S Rosewood Ave
>
20163063 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 11:48:33 AM
Creation date
11/16/2022 11:48:31 AM
Metadata
Fields
Template:
Permit
Permit Number
20163063
Full Address
514 S Rosewood Ave
Permit ID
229642
Master ID Number
2017-135794
Project Name
Miscellaneous Counter1 Permit
Street Number
000514
Street Direction
S
Street Name
Rosewood
Street Suffix
Ave
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
4/26/2017
Issued Date
4/26/2017
Finalized Date
6/6/2017
Flood Zone
X-0602320257J
Description of Work
Installation of roof mounted PV system. Worksheet attached to plans. All fees paid on 10192799
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
IXPEDITED PERMIT PROCESS FOR SMALL'SCALE PV SYSTEMS <br />STANDARD STRINC SYSTEM <br />The information in this guideline rs inrended to help local Jurisdictions and contractors identity when PV sysrem installations <br />are simple. needing only a basic review and when an insrallation is more complex It is likely that 50%-75% of all residential <br />systems will comply with these simple criteria. For projects thal fail to meet lhe simple criteria. resolution sreps have been <br />suggested to provide as a path to permit approval. <br />Required Injormation for Perrnit: <br />1 Site plan showing location of major components on rhe property This drawing need not be exactly to scale, but it <br />should represent relative location of components at site (see supplied example site plan) PV arrays on dwellings <br />with a S perimeter space at ridge and sides may not need separate fire service revrew. <br />2 Electrical diagram showing PV array configuration. wiring system. overcurrent protection, inverte( disconnects, <br />required signs. and ac connection to building (see supplied standard electrical diagram). <br />f. Specihcarion sheers and insullarion manuals (if available) for all manufactured components including, bur nor <br />limired ro. PV modules. inverter(s). combiner box. disconnects. and mounting system. <br />Step 1 : Structural Review o[ PV Array Mounting System <br />ls the aray to be mounted on a dehned, permitted rcof structure? EYes ENo <br />I No due to non-compliant roof or a ground mount. submit completed worhsheet Jor the structure WKS L <br />Roof Information: <br />1 ls the roohng rype Iightweighr (Yes = composition. lighrweight masonry. metal. etc )YES <br />UNo, submit completed worhsheet Jor rooJ structure WXS/ fNo = heqvy masonry, slate, etc...) <br />2 Does the roof have a single roof coveringu Elves Eno <br />IJ No, submit completed worhsheet lor roof structure WKSI. <br />f Provide merhod and rype of wealherproonng roof penerrations (e.g flashing, caulk)Flashing, geocell sealant <br />M oun tin g Sy st em Inlotmation <br />I ls lhe mounting structure an en neered product designed to mount PV modules with no nrore than an l S gap <br />beneath the module frames?ves E no <br />IJ No, provide detoils oJ structural attachment certified by a design professional. <br />2 For manufactured mounting systems, hll out information on the mounting system below <br />a tMounting Sys tem Manulactrrrer Z€P product Name and yo6"1X Comp Mount Type C <br />b Total Weigh t of PV Modules 2n6 12;15 536.19 bs <br />d. Weighr per A[achmenr Pornr (b - c)23.31 bs (if greater than 45 lbs, see WKS I ) <br />Maximum Spacing Berween Altachment Points on a Rail 48 inches (see producl manual for <br />maximum spacing allowed based on maxirnum design wind speed) <br />Total Surface Area of PV Modules (square leet)178.73 <br />Distributed weight ol PV Modulc on Rool (b + l)3.0 lbs/ft <br />IJ distrtbuted weight of the Pv system is gr t€r thsn 5 lbsff, see WKSI . <br />Step 2: Electrical Review o[ PV System (Calculations lor Electrical Diagram) <br />In order for a Pv system to be considered for an expedited permit process, the following must apply: <br />l. PV modules. utility-interacrive inverrers, and combtner boxes are idenrihed for use in PV syslems. <br />2. The PV array is composed of 4 series strings or less per inverter. <br />3. The total inverter capacity has a continuous ac power output 13,440 Watts or less <br />4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). <br />5. One of the standard electrical diagrams (E | . I , E l I a, E l I b, or E I . I c) can be used to accurately represent the PV <br />system. lnteractive PDF diagrams are available at www.solarabcs.org/permitting. <br />Fill out the standard electrical diagram completely. A guide to the electrical djagram is provtd.ed. to help the applicant <br />understand each blank to jll in. Il the electrical system is more complex than the standard electrical diagram can elJectively <br />communicate, provide an alternative diagram with appropriate detail. <br />2 ExpEDtrED PERMTT PRocEss FoR fv sysr[Ms <br />e <br />,t <br />s <br />c. Toral Number of Attachment Points 23
The URL can be used to link to this page
Your browser does not support the video tag.