,,,'SANTA <br />NA-'ffi <br />Planning & Building Agency <br />Building Satety Division <br />20 Givic Center Plaza <br />P.O. Box 1988 (M-'19) <br />Santa Ana, CA 92702 <br />(7'14) 647-5800 <br />www.santa.ana.or9 <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />sol-01 cBc 2013 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy ofthis form shall be attached to each of TWO sets of plans, of <br />minimum 11" x 17" size. lf answerinq NO to anv ofthe ouestions , Dlan check shall be required. <br />Project Address: 13 t S L o \^\.^ I ]\r 5\ <br />Contractor Company Name:S r^-...<(..^,-- <br />contractor License Number: <br />tl 5- \X 4 <br />2 <br />YES NO <br />Ntr <br />bo <br />Are the following applicable to the proposed project? <br />\Mll the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? <br />Wll the PV system be installed on a roof having only one rooflng layer with no <br />overlays? <br />Wll the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Wll the PV system weigh maximum 4 pounds per square feet or less? <br />Vvill the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Vvill the PV system be installed with a space of 2" minimum to l0" maximum between <br />the underside of modules and the surface of the roof? <br />Wll the PV system be installed without using any ballast system or counter-weight <br />system? <br />Wll the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Wll the minimum 5/16' lag screws be installed with a minimum ol2-112inch <br />embedment into roof rafters (with pre{rilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages ofthe plans VVET stamped and signed by a California <br />licensed professional engineer? (including prolect specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />6 <br />7 <br />. Eo <br />o\go <br />u ha <br />bo <br />'uu <br />bu <br />\n <br />,o\g <br />I <br />I <br />I certify und <br />Print Name: <br />Phone Num <br />Ity'of p <br />,, t\- <br />e ryuer e laws of the State of Cal <br />u"'' \\- -1 9\-a'lx Signature: <br />Date: 5 <br />Email Address <br />Rev: 6/1712015 <br />ia th above is true: <br />I