20163222 - Permit (2)
PBA
>
Building
>
Permits
>
S
>
Santa Clara Ave
>
1218 W Santa Clara Ave
>
20163222 - Permit (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 2:43:45 PM
Creation date
11/16/2022 2:43:44 PM
Metadata
Fields
Template:
Permit
Permit Number
20163222
Full Address
1218 W Santa Clara Ave
Permit ID
230365
Master ID Number
2017-136272
Project Name
Miscellaneous Counter1 Permit
Street Number
001218
Street Direction
W
Street Name
Santa Clara
Street Suffix
Ave
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
5/18/2017
Issued Date
5/18/2017
Finalized Date
6/22/2017
Flood Zone
X-0602320144J
Description of Work
Install (16) roof mounted solar panels. FEES PD ON 10193034.
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXPEDITED PERMIT PROCESS FOR SMALL-SCALE I]V SYSTEMS <br />The information in rhis guideline is inrended ro help local jurisdictions and contractors identify when PV system insrallations <br />are simple, needing onty a basic revieq and when an installation is more complex. It is likely that 50 % -75% of all <br />residential systems will comply with these simple criteria. For projecG that fail to meet the simple crileria. resolution steps <br />have been suggested to provide as a path to permit approval <br />Required lnJonnation for Petmit: <br />t. Sire plan showing locarion of ma;or componenrs on the properry This drawing need not be exactly to scale. but ir <br />should represenr relarive locarion of componenrs at sire (see supplied example site plan). PV arrays on dwellings <br />with a 3'perimeter space at ridge and sides may not need Separate hre service review <br />2. Elecrrical diagram showing PV array connguration. wiring system, overcurrent protection. inverter, disconnects. <br />required signs. and ac connection to building (see supplied srandard elecrrical diagram) <br />3 Specincarion sheets and insrallarion manuals (if available) lor all manufactured components including. but not <br />limired to, PV modules. inverter(s), combiner box, disconnec(s. and mounting system. <br />Step 1 : Structural Review o[ PV Array Mounting System / <br />]s the array to be mounted on a defrned, pcmitted rcof strucnrrez dyes Ll no <br />U No due to non-complnnt roof or a ground mount. submit compleed worksheel lor the structure WKS I . <br />Roof In|orrnation: <br />l. ls the roohng type lighrweight (Yes = composition. lightweight masonry, metal. etc <br />U No. submit completed wotksheet lor rooJ structure WFt @o = heavy masonry. slate, etc <br />2. Does rhe roof have a srngle roor coveringl l(/Yes ! tto <br />f No, submit completed worksheetror rooJ structure WKSI. <br />l. Provrde method and type of weatherproofrng roof penetations (e g. flashing, caulk) <br />M ount ing sy st ern I nJormation : <br />t y's <br />flqr|,ry/^ulk <br />l. ls the mounting structure an enggeered producr deslgned to mount PV modules wi(h no more lhan an l8' gap <br />beneath the module Frames? ZYes tto <br />f No, provide details oj stn)ctural dttachmmt certiled b! a design proJessional. <br />2. For manufactured mounting systems, hll out information on the mounting sysrem below <br />a. Mounring syrt"* il"nuf".rrr.r1fi,ltrp0l&qProducr Name uno ioart*3P\'o) )dh G tl ( <br />b. Toral weight or PV Modules and aatst Allt-lbs <br />c. Toral Number o[ Attachment Polnts JO <br />d. weighr per Artachmenr point tb - c) ?l.d] lbs(if greater than 45 lbs.seewKsl) <br />rnches (see product manual fore. Maximum Spacing Between Attachmenr Point <br />maximum spacing allowed based on maximu <br />f. To(al Surface Area of Pv Modules (square feet) <br />s on a Rarl <br />m desrgn wrnd speed)11{ r,' <br />Step 2 <br />g. Disrribured weighr of PV Module on Roof (b * D .t7 lbs/fr' <br />IJ distributed v,rctght oj the Pv system ts gleatq than 5 lbs[f , see wl<Sl. <br />Electrical Review o[ PV System (Calculations for Electrical Diagram) <br />ln order for a PV slEtcm to be considered for an expedited Permit Process, the following must apply: <br />l. PV modules, urility.inreracrive inveners, and combiner boxes are identified for use in PV systems. <br />2. The PV array is composed of 4 series strings or less Per invener. <br />3. The total invener capacity has a continuous ac power output I f,44O watts or less <br />4. The ac interconnecrion point rs on the load side of service disconnecting means (690.64(8)). <br />5. One of rhe srandard electrical daagrams (El .l . El .l a. El .l b. or El .l c) can be used (o accurately represent the PV <br />system. lnteractive PDF diagrams are available at www solarabcs.o.g/permi(ting <br />Fill out the standard electical diagram completely A quide to the tlectrical diagram is pro|ided to help the aPplicant <br />understand each blank rollt in I lhe electrical syste,rl is tnorc complex lhan the standat"d electical diagraDt can clJectivel)' <br />communicate. provide dn alterrutive diag/am with appropriate detail <br />EXPEDITEI) PTRMIl-IROCESS TOR PV SYSTEMS <br />7l
The URL can be used to link to this page
Your browser does not support the video tag.