Laserfiche WebLink
PV f OOLKI DOCUfltENf #4 <br />Solor PV Stondord Plon - Simplified <br />Microinverler qnd ACM Systems for <br />One- ond Two-Fomily Dwellings <br />SCOPE: Use thrs plan ONLY for systems u5ing utality-interactive Microanverters or AC Modules (ACM) not erceeding a combined sy5tem <br />AC inverter output rating of 10 kW with a maximum of 3 branch circuits, one PV module per inverter and with PV module l5C maximum <br />of 10-A DC, installed on a roof of a one- or two-family dwelling or accessory structure. The photovoltai. system must interconnect to a <br />single-phase AC service panel of 120/240 Vac with service panel bus bar rating of 225 A or less. This plan is not intended for bipolar <br />systems, hybrid systems or systems that utiliie storage batteries, charge controllers or trackers. Systems must be in compliance with <br />current California Building Standards Codes and local amendments of the authority having jurisdiction (AHJ). Other articles of the <br />California Electrical Code (CEC) shall apply as specified in section 690.3. <br />MANUFACTURER'S SPECIFICATION SHEETS MUST BE PROVIDED for proposed inverters, modules, combiner/junction boxes and racking <br />systems. lnstallation inst.uctions for bonding and grounding equipment shall be provided and local AHJs may require additional details <br />Listed and labeled equipmenl shall be installed and used in accordance with any instructions included in the listing or labeling (CEC <br />110.3). Equipment intended for use with PV system shall be identified and listed for the application CEC 690.4{D). <br />Applicont ond Site lnformolion <br />Job Address: 2545 N HESPERTAN ST. SANTA ANA,CA92i0(,Permit # <br />tr AC Module (ACM) <br />Number of ACMs installed: <br />Note: Listed Alternoting-Cutent Module (ACM) is defined <br />n CEC 690.2 ond nstolled pet CEC 690.6 <br />Contractor/Eng ineer Name: ALPIIA ELECTRIC AC/DC License fi and class. # 960172 (C-10) <br />Date: 612612017 Phone Number: (714) 493-9920 <br />l. Generol Requirements ond Syslem lnformolion <br />E Microinverter <br />Number of PV modules installed: 24 <br />Number of Branch Circuits, 1., 2 or 3 2 <br />1,.4 <br />Actual number of Microinverters or ACMs per branch circuit: 1 12 2. 12 3._ <br />Total AC system power rating = (Total Number of Microinverters or ACMS) * (AC inverter power output) <br />= 7200 Watts <br />Lowest expected ambient temperature for this plan in Table 1: For -1'to -5" C use 1.12 or <br />for -6" to -10" C use 1.14 correction factors. <br />Average ambient high temperature for this plan: = +47" C <br />Note: For lower expeded ambient or higher average ambient high temperatures, use Comprehensive Standard Plan. <br />1.5 <br />2. Microinverter or ACM lnformotion ond Rotings <br />Microinverters with ungrounded DC inputs shall be installed in accordance with CEC 690.35 <br />Microinverter or AcM Manufacturer ENPHASE <br />Model TQ6PLUS-72-2-US <br />1.1 <br />1.2 <br />1.3 <br />2.1 Rated (continuous) AC output po wer: 3oo Watts <br />Signature: <br />Number of Microinverters installed: 24