Template:
Permit
Permit Number
20163798
Full Address
760 W Aster Pl
Permit ID
232614
Master ID Number
2017-137729
Project Name
Miscellaneous Counter1 Permit
Street Number
000760
Street Direction
W
Street Name
Aster
Street Suffix
Pl
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
7/31/2017
Issued Date
7/31/2017
Finalized Date
8/17/2017
Flood Zone
X-0602320144J
Description of Work
Install (28) roof mounted solar panels. FEES PD ON 10193670
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXPEDITED PERMIT PROCESS FOR SMALL-SCALE PV SYSTEMS <br />MICRo-INVERTER <br />The information in this guideline is intended to help local Jurisdictions and conrracrors idenrify when PV sysrem installarions <br />are simple. needing only a basic review, and when an insallation is more complex. lr js likely rhar 50 % -75 % of all residenrial <br />systems will comply with these simple criteria. For proJec6 that fail to meer (he simple criteria. resolution steps have been <br />suggesred to provide as a path to permir approval. <br />Requireil Infonnation for Peflnit: <br />I Sire plan showing location of major components on the properfy. This drawing need nor be exacdy to scale, but ir <br />should represent relatrve locarion of componenrs at sire (see supplied example sire plan). Pv arrays on dwellings <br />with a 3'perimeter space at ridge and sides may not need separate hre service review. <br />2 Electrical diagram showing PV array conhguration, wiring sysrem. overcurrent protecrion, invertet disconnecrs. <br />required signs, and ac connection ro building (see supplied srandard elecrrical diagram). <br />3. Speci6catron sheers and insrallation manuals (iF available) for all manufactured components including, bur not <br />limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. <br />Step 1 : Structural Review o[ PV Array Mounting System <br />ls the array to be mounted on a defrned, permifted roof structurei Eyes f]tto <br />l.f No due to non-compliant rooJ or a ground mount, submit completed worhsheet Jor the stucture WKS I . <br />Roof Information: <br />l. Is the roohng type lighrweight (Yes = composition. lightweighr masonry. metal. erc. .)Yes <br />Il No, submit completed worhsheet for roof stucture WKSI (No = heayy masonry, slate, etc.. .) <br />2 Does the roof have a srngle roof coveringr EIyes Eno <br />If No, submit completed worhsheet Jor roof sffucture wNSl . <br />f. Provrde method and type of weatherproofing roof penetrations (e.g. flashing. caulk)Flashing <br />M ounting S! sten Infonnation : <br />I Is the mounting structure an en ineered product designed to mount PV modules wirh no more than an I8" gap <br />beneath the module frames?Yes ! no <br />lf No, provide detaik ol structurol atta.chment certiled by a destgn prcfessional. <br />2 For manufacrured mounling systems, hll out informarion on the mounting sysrem below <br />a. Mounring Sys tem Manufacrurer SWH roducr Name and 1r4o6"1gSolar Mount <br />b. Total Weight of PV Modules and Rails 1288 Ibs <br />c. Total Number of Athchmenr Points 48 <br />d. weighr per Arrachmenr Pornr (b+c) 2684 lbs (iF grearer than 45 lbs,seewKSl) <br />e. Maximum Spacing Between Attachment Points on a Rail & rnches (see product manual for <br />maximum spacing allowed based on maximum design wind speed) <br />f. Total Surface Area of PV Modules (square feer)494.'18 fr, <br />g. Distributed Weight of PV Module on Roof (b:' 0 2.61 lbs/ft'? <br />Il dktributed weight ol the Pv system is geater than 5 lbstP, see WKSI . <br />Step 2: Electrical Review o[ PV System (Calculations for Electrical Diagram) <br />In order for a PV system to be considered for an expedited permit pmcess, the following must apply: <br />I PV modules, utility-interactive inverters, and combiner boxes are identihed for use in PV systems. <br />2. The PV array is composed of 4 series strings or less per inverter. <br />3 The total inverter capacity has a continuous ac power output 13,440 watrs or less <br />4. The ac inrerconnection poinr is on lhe load side of service disconnecting means (690.64(8)). <br />5. one of the standard elecrrical diagrams (E L I , E l I a, E L I b, or E l I c) can be used to accurately represent the Pv <br />system. Interacrive PDF diagrams are available at wwwsolarabcs.org/permifting. <br />Fill out the standard. electrical diagram completely. A guide to the electrical d.iagram is provid.ed to help the applicant <br />understand each blank to ill in. If the electrical system is more comptex than the standard electrical diagram can elJectively <br />communicate, provide an alternative diagram vith aryropriate detaiL <br />7 ExpEDrrED PERMTT PRocESS FoR PV sysrEMs - MIcRo-INVERTER
The URL can be used to link to this page
Your browser does not support the video tag.