My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20164032 - Permit (2)
PBA
>
Building
>
Permits
>
B
>
Borchard Ave
>
3106 W Borchard Ave
>
20164032 - Permit (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2022 4:04:17 PM
Creation date
11/18/2022 4:04:15 PM
Metadata
Fields
Template:
Permit
Permit Number
20164032
Full Address
3106 W Borchard Ave
Permit ID
233671
Master ID Number
2017-138411
Project Name
Miscellaneous Counter1 Permit
Street Number
003106
Street Direction
W
Street Name
Borchard
Street Suffix
Ave
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
9/5/2017
Issued Date
9/5/2017
Finalized Date
12/19/2017
Flood Zone
X-0602320256J
Description of Work
Install new 5.7 kw roof mounted solar PV system (19 panels) ALL FEES PAID ON 10194034
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXPEDITED PERMIT PROCESS FOR SMALL-SCALE PV SYSTEMS <br />STANDARD STRING SYSTEM <br />The information in rhis gurdeline is inrended to help loca I Jurisdictions and contractors identiFy when PV system installations <br />are sirirple. needing only a basic review and when an installatron is more complex. lt is likely thar 50%-75 of all residenrral <br />systems will conrply with these simple criteria. For projects that fail to meet Ihe simple criteria. resolution steps have been <br />suggested to provide as a path to permit approval. <br />Required Infonnation for Permit: <br />1 site plan showing location of malor components on the property This drawrng need not be exactly to scale, but lt <br />should represent relative location of components at site (see supplied example site plan) PV arrays on dwellings <br />with a S perimeter space at ridge and sides may not need separate hre service review. <br />2 Electrical diagram showing PV array conf,guration, wiring system, overcurrent protection, invertet disconnecls. <br />required signs, and ac connection to building (see supplied standard electrical diagram). <br />f Speci6cation sheets and installalion manuals (if available) for all manufactured components including, but not <br />limired to, PV modules. invener(s), combiner box. disconnecls. and mounting sysrem <br />Step 1 : Structural Review of PV Array Mounting System <br />Is the array to be mounted on a dehned, permitted rcof structurel Eyes Eno <br />l-f No due to non-contpltant rooJ or a ground mounl, submit completed worhslrcet.for the structure wKSl . <br />Roof Infonnation: <br />YESI Is the roohng type lightweight (Yes = composition. lighrweight masonry, metal, etc. ) <br />U No, submit completed worksheet lor roof structure wl<Sl (No = heavy masonry, slate, etc. . ) <br />2. Does rhe roof have a srngle roof coveringz Eyes E r'lo <br />IJ No, submit completed worksheet lor roo.f structure wxsl. <br />f Provide method and type of weatherproohng roof penetrations (e.g flashing, caulk)Flashing, geocell sealant <br />M ounting Sy st en Information : <br />l. ls lhe mounting structure an elgineered producr designed to rnount PV modules with no more than an 18" gap <br />benearh rhe module frames? E Yes E no <br />If No. provide details oJ structural attachment certifred by a d,esign proJessional. <br />2 For manufactured mounting systems, hll out information on lhe mounting system below: <br />a lvlounting Sys tem [.4anufacturer ZeP Product Name and 14o6"1,4 Comp Mount Type C <br />b Toral werdhl ot PV l\4odules "n6 <br />p'15 1024.92 lbs <br />c. Total Number of Atrachmen( Points .t6 <br />d. werghr per Arrachmenr p6;n1 1[=6122'28 lbs(if greater rhan 45 lbs.seewKsl) <br />e Maximum Spacing Berween Attachment Poinrs on a Rail 48 inches (see product manual for <br />maximum spacing allowed based on maximum design wind speed) <br />Tolal Surface Area of PV Modules (square feet)34'1.64 frr <br />g Disrribured Weighr of PV Module on Roof (b: l)3.0 lbs/tu <br />IJ dist/ibuted weight of the PV slstem is gaester than 5 lbslft, see WKSI - <br />Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) <br />ln order for a PV system to be considered for an expedited permit process, the following must apply: <br />I PV modules, utility'interactive inverters, and combiner boxes are identified for use in PV systems. <br />2 The PV array is composed of 4 series strings or less per inverter <br />3. The total inverter capacity has a conlinuous ac power ourput 11,440 Watts or less <br />4. The ac interconnection point is on the load side of service disconnecting means (690.64(8)) <br />5 One of the standard electrical diagrams(El.l, El.la, El.lb,orEl I c) can be used to accurately represent the PV <br />system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. <br />Fill out the standard elecfrical diagram complelely. A guide to the electrical diagram is proyided to help the applicant <br />undersland each blank to lll in. lf the electrical system is more complex than the standard electrical diagram can elfectively <br />communicate, provide an alternative diagram with appropriate detail. <br />2 ExpEDrrED f[RMrr PRocrss FoR PV sysrEMs
The URL can be used to link to this page
Your browser does not support the video tag.