Laserfiche WebLink
Pl.nnlng & Bulldlng Agoncy <br />Bulldlng Safety Dlvision <br />20 Clvic Conter Plazs <br />P.O. Box r9EB (M-19) <br />S.nta Ana, C492702 <br />(71/t) 6475E00 <br />www.srnta-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />GHECKLIST <br />soL-01 cBc 2013 <br />Solar Photovoltalc (PV) Checkllst for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructlons: Th€ licensed conlractor ol record shall complet€ all sections, answer the ten qu€stions and <br />sign th6 certiflcation section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimuml'1"x17"size. lf answerlnq NOtoanvof the questlons. plan check shall be requlred. <br />Project Address:617 Diamond St, Santa Ana, CA 92703, US <br />Tcsla <br />4 <br />5 <br />2 <br />3 <br />6 <br />7 <br />Contractor Company Name: <br />Contractor Llconse Number: <br />YES NO <br />tr tr <br />8 trtr <br />9 Etr <br />10 tro <br />trtr <br />tro <br />trtratr <br />tro <br />tro <br />Aro the followlng appllcabl€ to the proposed projoct? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.11 of the Califomia Fire Code, and is this shown on the roof plan? <br />Wll th€ PV system be installed on a roof having only one roofing lay€r with no <br />overlays? <br />Will the PV array be flush mounted to tho €xisting roof so that the plane of the <br />modules (panels) are parallol to the plan€ of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be inslalled where the modules do not overhang any roof edges <br />(such as eaves, gabled Ends, ridges and hips)? <br />Will the PV systsm be installed with a space of 2" minimum to 10" maximum between <br />the underside of modules and the surface of the roon <br />Will the PV syslem be installed without using any ballast system or counter-weight <br />system? <br />Wll the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Wll th€ minimum 5/16" lag screws be installed with a minimum ot 2-112 inch <br />embsdment into roof rafters (with pre{rilled holes) and is this minimum embedment <br />shown on the plans? <br />tue ALL the structural pag6s of the plans WET stamped and signed by a Califomia <br />licensed professional engineer? (including proiect spocific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />I cortlty under penalty ot poriury under the laws of the State of Callfoinla that tho above ls true: <br />print Name: Chris Corniola Sign <br />Phone Number:702-785-2998 Darg. t0/27 /17 <br />Emait Address: ccorniola@tesla.com <br />ature: ' ' <br />R€v: 8/1712015 <br />*-SANTA <br />J <br />lLi\\t\c <br />1.