Laserfiche WebLink
*,,,SANTA <br />ANA <br />ll.l\\lI <br />e0[t0t\c <br />IGtIiI <br />Plannlng & Buildlng Agancy <br />Bulldlng Safety Dlvision <br />20 Clvic Conter Plaza <br />P.o. Box r988 (M-19) <br />Santa Ana, CA 92702 <br />(71't) 647-5800 <br />www'aanta-ana,org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />soL-01 cBc 2013 <br />Solar Photovoltalc (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Onty <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11" x 17" size. lf answerinq NO to anv of the questions. plan check shall be required. <br />Project Address . '1321 N Jackson St, Santa Ana, CA 92703, US <br />Contraclor Company n"-.. Solal City <br />Contractor Llcense Number:BBB 104 <br />YES NO Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.1 'l of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV array be flush mounted lo the existing roof so that the plane of the <br />modules (panels) are parallel to the plans of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2'minimum to 10" maximum between <br />lhe underside of modules and the surface of the roof? <br />Will the PV syslem be installed without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum ol2-112 inch <br />embedment into roof rafters (with predrilled holes) and is this minlmum embedment <br />shown on the plans? <br />Are ALL the slructural pages of the plans WET slamped and signed by a Califomia <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />tr tr <br />2 trtr <br />Eltr <br />trtrtrtr <br />trD <br />Eltr <br />3 <br />4 <br />5 <br />6 <br />7 <br />I trtr <br />9 trtr <br />10 tro <br />I certify under penalty of porjury under the laws of the State of C <br />print Name: l\,4elissa Foxx Sign <br />phone Numbar: 702-7 85-2998 <br />Email Addr6ss: mfoxxsarmiento@tesla.com <br />Rov 8/1712015 <br />Date:B/tJ <br />ia that the ove ls true: <br />1