Laserfiche WebLink
RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />sol-01 cBC 2013 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Onty <br />lnstruclions: The licensed contractor of record shall fill in the address of the project, contractor's <br />licensing information and answer questions 1 -10 below. Complete and sign the certification section. <br />"*lf answering NO to any of the questions, plan check shall be required.** <br />P roj ect Address: 126 SOUTH GUNTHER STREE1' SANTA ANA, CA92704 <br />Contractor Company Name:STAR SUN SOLAR <br />Contractor License Number:$ 1008302 <br />6 tru <br />Are the following applicable to the proposed project? <br />Will the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 3 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to l0" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV system layout provide a three-foot wide clear access pathway per the <br />latest edition oI "Guideline for Fire Safety Elements of Solar Photovoltaic Systems" <br />by OCFA? (Guideline available on the OCFA website: htto://uryvw.ocfa.orq) <br />Do the plans show a maximum horizontal anchor spacing of 6 feet? <br />Do the plans show a minimum of 2-112 inch lag screw embedment into roof rafters? <br />Are ALL the structural pages of the plans WET stamped and signed by a California <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />Eltr <br />I certify under penalty of perjury under the laws of the State of California that the above is true: <br />Print name: Shane Cunningham Signature <br />Phone Number: <br />Email Address <br />2 <br />3 <br />4 <br />5 <br />8 trtr <br />9. Etr <br />10 EE <br />YES NO <br />Ertr <br />Etr <br />Etr <br />Etr <br />atr <br />7 <br />Rev:2h7/2015 <br />7t4 370.8877 Date: 81312018 <br />*,SNIA <br />NA,ffi <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, C492702 <br />(714) 647-s800 <br />www.santa.ana,org <br />1