Laserfiche WebLink
Plannlng & Building Agency <br />Bulldlng Saf€g Divi6ion <br />20 Clvic Canter Plaza <br />P.O. Bor 1988 (U-19) <br />Sant Ana, CA 92702 <br />(71lt) 647-5800 <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />GHECKLIST <br />soL41 CBC 2013 <br />Solar Photovoltalc (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructionsr Ths licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the c€rtification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11" x 17' size. lf answerlng NO to any of the questons, plan check shall be requlred. <br />Project Address:'1502 W River Ln, Santa ana, CA 92706 <br />2 <br />J <br />Contractor Company Name: <br />contractor Llcense Numbe.: 888 1 04 <br />YES NO Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three.foot wide clear access pathways <br />per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? <br />IMll the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV anay be flush mounted lo the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Wll the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2'minimum to 10'maimum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be inslalled without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is lhis maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch <br />embedment into roof rafters (with preirilled holes) and is this minimum embedment <br />shown on the plans? <br />Aro ALL the structural pag€s of the plans WET stamped and signed by a California <br />lic€ns€d professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacture/s PV support information.) <br />atr <br />8 @tr <br />9 trtr <br />10.trtr <br />gltr <br />atr <br />Eltr <br />@tr <br />Eltr <br />Elu <br />4. <br />5. <br />6. <br />7. <br />I cerllfy under penalty of periury under tho laws of tho State of California that the above is true: <br />print Name: MIKE CURRAN Sign "gr". <br />Michael Curran ll);ll'j;illli,,'i,'ll,lj'l1'l;;itil <br />phone Number: 609-634-2395 <br />Email Address: mcurran@tesla.com <br />Date . 5/3r/2018 <br />,,-SANTA <br />ANAJIiilil <br />Tesla <br />I <br />Rev: 8/1712015