Laserfiche WebLink
SECOND LEVEL <br />OVERALL <br />BUILDING PLAN <br />A-202 <br />SCALE: 1/8"=1'-0"1SECOND LEVEL OVERALL BUILDING PLAN <br />Company: <br />Address: <br />Phone No. <br />Project Contact: <br />Email: <br />Principal: <br />Project Manager: <br />ADC Project No: <br />Ryan RatcliII <br />rratcliII#adcollaEorative.com <br />Chris Weimholt <br />laguna hills, ca 92653 <br />www.adcollaborative.com <br />23231 south pointe drive <br />949.267.1660 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />V <br />E <br />T <br />E <br />R <br />A <br />N <br />S <br /> <br />V <br />I <br />L <br />L <br />A <br />G <br />E <br />Client <br />COPYRIGHT C <br />20160136 <br />Sh <br />e <br />e <br />t <br /> <br />I <br />s <br />s <br />u <br />e <br /> <br />D <br />a <br />t <br />e <br />Sh <br />e <br />e <br />t <br /> <br />I <br />s <br />s <br />u <br />e <br /> <br />& <br /> <br />R <br />e <br />v <br />i <br />s <br />i <br />o <br />n <br /> <br />L <br />o <br />g <br />8- <br />7 <br />- <br />2 <br />0 <br />1 <br />8 <br />1S <br />T <br /> <br />C <br />I <br />T <br />Y <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />8 <br />- <br />7 <br />- <br />2 <br />0 <br />1 <br />8 <br />JAMBOREE HOUSING CORPORATION <br />17701 COWAN AVE, SUITE 200 <br />IRVINE, CA 92614 <br />949-263-8676 <br />Ryan RatcliII <br />33 <br />1 <br />4 <br /> <br />W <br />. <br /> <br />F <br />I <br />R <br />S <br />T <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />CHRISTOPHER <br />WEIMHOLT <br />No. C-32271 <br />10/31/19 <br />RENEWAL DATE <br />BUILDING PLAN KEYNOTES <br />1 <br />2 <br />3 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />BUILDING PLAN NOTES <br />1.WHERE INFORMATION IS UNCLEAR OR A CONFLICT IS FOUND, CONTRACTOR <br />IS RESPONSIBLE FOR CONTACTING THE ARCHITECT PRIOR TO PROCEEDING. <br />2.DIMENSIONS INDICATED, U.N.O. ARE TO THE FACE OF STUD, OR FACE OF <br />CONCRETE. EXTERIOR WALL STUDS ARE TO ALIGN WITH THE FACE OF <br />CONCRETE DIRECTLY BELOW U.N.O. <br />3.REFER TO SHEETS A-000 THRU A-025 FOR BUILDINGS OCCUPANT LOAD, <br />EXITING COMPLIANCE, TRAVEL DISTANCE, FIRE RATINGS AND ADDITIONAL <br />INFORMATION NOT SHOWN. <br />4.REFER TO ENLARGED PLANS, WHERE APPLICABLE, FOR ADDITIONAL <br />DIMENSIONS, NOTES AND INFORMATION NOT SHOWN. <br />5.SLOPE AT PATH OF TRAVEL MAY NOT EXCEED 1/4" PER FOOT IN ANY <br />DIRECTION. REFER TO SHEET A-791 & A-792 FOR DISABLED ACCESS <br />REQUIREMENTS <br />6.PENETRATIONS AT FIRE RATED ASSEMBLIES TO BE IN COMPLIANCE WITH <br />THE C.B.C, CHAPTER 7. REFER TO FIRE RATED DETAILS ON SHEET A-711 & <br />A-712 FOR ADDITIONAL INFORMATION NOT SHOWN. <br />7.FIRE DAMPERS ARE TO BE INSTALLED IN COMPLIANCE WITH C.B.C. SECTION <br />717.6.2 WHERE PENETRATING THE FIRE RATED FLOOR/CEILING ASSEMBLY. <br />8.VERTICAL AND HORIZONTAL FIRE BLOCKING TO COMPLY WITH C.B.C. <br />SECTION 718.2 <br />9.CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ALL REQUIRED <br />ACCESS PANELS IN FLOORS AND CEILINGS. ACCESS PANELS ARE TO BE <br />PRIMED AND PAINTED TO MATCH ADJACENT FINISH. WHERE PANELS <br />PENETRATE FIRE RATED ASSEMBLIES, PANELS SHALL MEET THE <br />REQUIREMENTS IN C.B.C. SECTION 718. <br />8.FIRE EXTINGUISHER CABINETS SHALL BE LOCATED IN SUCH A MANNER AS <br />TO NOT EXCEED 75' TRAVEL DISTANCE FROM ANY POINT IN THE BUILDING. <br />TYPE AND LOCATION AS REQUIRED PER THE INTERNATIONAL FIRE CODE. <br />9.CONTRACTOR TO PROVIDE FURRING AS REQUIRED TO MAINTAIN LEVEL AND <br />PLUMB WALL, FLOOR AND CEILING FINISHES. <br />10.REFER TO THE BUILDING AND WALL SECTIONS FOR VERTICAL DIMENSIONS <br />AND ADDITIONAL ASSEMBLY DETAILS. VERTICAL DIMENSIONS U.N.O. ARE <br />TAKEN FROM THE TOP OF FOUNDATION OR TOP OF STRUCTURAL <br />SHEATHING. <br />11.REFER TO THE STRUCTURAL ENGINEERS PLANS FOR FRAMING MEMBER <br />SIZES, SPACING, REQUIRED FASTENING, HOLDDOWN-SYSTEMS, AND SPECIAL <br />INSPECTION REQUIREMENTS. <br />12.REFER TO THE MECHANICAL ENGINEERS PLANS FOR LAYOUTS, HVAC <br />ROUTING, ACOUSTICAL ISOLATION AND PENETRATIONS, EXHAUST <br />TERMINATIONS AND SOFFIT LAYOUTS <br />13.REFER TO THE ELECTRICAL ENGINEERS PLANS FOR EXIT SIGN LOCATIONS, <br />FOOT-CANDLE LIGHTING COMPLIANCE AND OUTLET AND SWITCH MOUNTING <br />HEIGHTS AND LOCATIONS. <br />14.REFER TO THE PLUMBING ENGINEERS PLANS FOR PIPE PENETRATION <br />LOCATIONS, ACOUSTICAL ISOLATION, AND FIRE STOPPING INSTALLATION. <br />15.FOR ACCESSIBILITY REQUIREMENTS OF BUILDING ELEMENTS, REFER TO <br />SHEETS A-790 THRU A-792 <br />16.ASSISTIVE LISTENING SYSTEMS REQUIRED IN ASSEMBLY AREAS, <br />CONFERENCE AND MEETING ROOMS SHALL COMPLY WITH 2016 C.B.C. <br />SECTION 11B-706. REFER TO 5/A-793. <br />FIRE RISER <br />FIRE ALARM ANNUNCIATOR PANEL <br />GAS METERS <br />NOT USED <br />EXTERIOR 3" DOWNSPOUT. DOWNSPOUT TO CONNECT INTO STORM <br />SYSTEM PER CIVIL. <br />PRE-CAST CONCRETE PLANTERS 18"X48"X24" <br />DROPPED HEADER OVERHEAD. REFER TO ELEVATIONS <br />MOP SINK <br />FLATWORK AT GROUND FLOOR PATIOS PER LANDSCAPE ARCHITECT <br />2A:10BC FIRE EXTINGUISHER PER DETAIL 20/A-710 <br />PIPES FROM ROOF DRAINS, ROOF DRAIN OVERFLOWS AND FROM FLOOR <br />DRAINS FROM FLOORS ABOVE. FOR ADDITIONAL INFORMATION, REFER <br />TO CIVIL AND PLUMBING DRAWINGS. PENETRATIONS THRU RATED <br />ASSEMBLIES PER SHEETS A-710 THRU A-714 <br />NOT USED <br />AWNING, REFER TO EXTERIOR ELEVATIONS & SHEET A-772 <br />METAL RAILING, REFER TO DETAIL 11/A-720 <br />WALL MOUNTED ROOF ACCESS LADDER <br />COLLECTOR HEAD AND OVERFLOW SCUPPER. <br />CLASS A TPO ROOFING BY FIRESTONE. 60 MIL ULTRAPLY, WHITE, CLASS <br />A, ASTM E-108, UL-790. WITH A THREE-YEAR SUBCONTRACTOR <br />GUARANTEE AND A MINIMUM 20-YEAR MANUFACTURERS WARRANTY. <br />16 <br />SYMBOLS & LEGEND <br />UNIT XX <br />XXXX <br />A-XXX <br />UNIT TYPE / ROOM NAME <br />UNIT ADDRESS / ROOM NUMBER <br />SHEET NUMBER FOR ENLARGED PLAN <br />1-HOUR RATED WALL. REFER TO DETAILS ON SHEET A-710 <br />1-HOUR RATED FIRE BARRIER AT STAIRWELLS AND OCCUPANCY SEPARATION. 50 <br />STC PROVIDED TO MEET ACOUSTICAL REQUIREMENT. REFER TO DETAIL 2/A-710 <br />FOR SINGLE WALL AND 3/A-710 FOR DOUBLE STUD WALL <br />1-HOUR RATED PARTITION. 50 STC PROVIDED TO MEET ACOUSTICAL <br />REQUIREMENT. REFER TO DETAIL 2 OR 3/A-710 <br />1-HOUR RATED FIRE PARTITION AT CORRIDOR/DWELLING UNIT & DWELLING <br />UNIT/DWELLING UNIT. REFER TO DETAILS 13 OR 14 ON A-710 <br />CONCRETE ROOF TILE BY EAGLE ROOFING OR EQUAL. COLOR TO <br />BE APPROVED BY ARCHITECT. <br />17 <br />14 <br />15 <br />4 <br />MU <br />MOBILITY UNIT. UNIT TO MEET REQUIREMENTS OF CBC CHAPTER 11B <br />CU <br />COMMUNICATION UNIT. UNIT TO HAVE ASSISTED LISTENING ENHANCEMENTS <br />AL <br />COMMON AREA ROOM TO HAVE ASSISTED LISTENING DEVICES INSTALLED