Laserfiche WebLink
SANTA <br />ANA <br />Plannlng & Bulldlng eiancy <br />Bulldlng Sltoty Dlvision <br />20 Clvic Contor Pl.za <br />P.O. Box rsEE (t{-19) <br />Santa Anr, CA 92702 <br />(71tl) 6/U-5800 <br />www,aant -ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKL!ST <br />soL41 CBC 2013 <br />Solar Photovoltaic (PV) Checkllst for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructlons: The licensed contractor of record shall complete all sections, answer lhe ten questions and <br />sign the certification section <br />minimum 1 1" x 17" size. lf a <br />below. A copy of thi <br />nswsrinq NO to an <br />s form shall be attached <br />v of the questions. Dla <br />to each of TWO sets of plans, of <br />n check shall be requlred. <br />3709 S OLIVE ST. Santa Ana, CA 92707, USProlect Address: <br />Contractor Company Name . Solar City <br />888104Contractor Llcense Number: <br />YES NOEtr1 <br />Are the followlng appllcable to the proposed proiect? <br />Will the PV system layout provide the required threejoot wide clear access pathways <br />per Section 605.11 of the California Fire Code, and is this shown on the roof plan? <br />Will th€ PV system b€ installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed whers the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to 10' maximum between <br />th€ underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />syslem? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum honzontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum o12'112 inch <br />embedment into roof rafters (with predrilled holes) and is this minimum emb€dment <br />shown on the plans? <br />tue ALL the structural pages of the plans WET stamped and signed by a Califomia <br />licensed professional engineer? (including prolect specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />2 EIE <br />a trtr <br />9 EEI <br />Elo <br />Etr <br />EO <br />tro <br />ao <br />4 <br />5 <br />6 <br />7 <br />10.tro <br />I cortlfy under penalty of perJury under the laws of the <br />Print Name: <br />310.362.7551 <br />DANIEL WISE S <br />Callfornla that the above ls true: <br />T)^1)* <br />Stato o, <br />ignature <br />Phone Number <br />Email Address: <br />R6v: &1712015 <br />DWrSE@SOLARCTTY.COM <br />Dab.6/6/20t7