20163533 - Permit
PBA
>
Building
>
Permits
>
S
>
Susan St
>
412 N Susan St
>
20163533 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2021 9:19:38 AM
Creation date
5/27/2021 9:19:37 AM
Metadata
Fields
Template:
Permit
Permit Number
20163533
Full Address
412 N Susan St
Permit ID
231421
Master ID Number
2017-136916
Project Name
Miscellaneous Counter1 Permit
Street Number
000412
Street Direction
N
Street Name
Susan
Street Suffix
St
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
6/20/2017
Issued Date
6/20/2017
Finalized Date
10/11/2017
Flood Zone
X-0602320256J
Description of Work
Install pv roof mounted solar panels. Per Expedited Permit Process For PV Systems Standard String System. Fees paid on 10193312.
Nature of Work
Solar Panels
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />System AC Srze <br />NTS Dale <br />PV MODULE RATINGS @ STC (Guide Seclion 5) <br />MODULE MAKE ' , ar' Wtr l,/ <br />uooure lrooer . I7J <br />NOTES FOR ALL DRAWNGSI <br />OCPD . OVERCURRENT PROTECIION DEVICE <br />SIGNS_SEE GUIDE SECTION 7 <br />SIGN FOR DC DISCONNECT <br />PHOTOVOLTA]C POWER SOURCE <br />NATIONAL ELECTRICAL CODE' REFERENCES <br />sHowN as rNEc xxx xx) <br />RATED MPP CURRENT <br />RATED MPP VOLTAGE <br />MAX SYSTEM VOLTAGE <br />MAX CIRCUIT CURRENT <br />156 ^79 "4,MAx POY\,€R-POINI CURRENT 0w) <br />MAX POWER.POINI VOLTAGE ryMF) <br />I <br />OPEN.CIRCUIT VOLTAGE {Vtr} <br />SHORT.CIRCUIT CURRENT (*) <br />MAX SERIES FUSE (OCPO) <br />MAXTMUM POVIER (PMAI) <br />MA( VOLTAGE{TYP oq}VE) <br />VOC TEMP COEFF (mV/oCEl or%/'CO) <br />I <br />IF COEFF SUPPLIED CIRCLE UNITS <br />i,?INVERTER RATINGS (Guide Section 4) <br />\9 ),q, <br />(0.o <br />^lYr <br />,6,o <br />l3o <br />!bqstsl <br />(a <br />INVERTER MAKE <br />nvenren uooer ) <br />MAX DC VOLT RATING <br />MAX POV\ER @ 40"C <br />t!! <br />85 <br />;t B1 <br />o - rf p-v5 -\WARNING: ELECTRICAL SHOCK <br />HAZARD_LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION7o{ <br />9SO <br />/ual4';o <br />7c, <br />SIGN FOR INVERTER OCPD AND <br />AC OTSCONNECT (F USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />NOMINAL AC VOLTAGE <br />MAX AC CURRENT <br />MAX OCPD RATING <br />A <br />I etAC OUTPUT CURRENT <br />NOMINAL AC VOLTAGE () <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />NOTES FOR ARRAY CIRCUIT WRING (Gude Secllon 6 and I and Appendlx O) <br />1 ) LovltS I EXPEC I AMBTEN I I ET PERA I JRE BASED ON ASHRAE MlNlr\rUM l\,rtEAN <br />ExTREME OBY BUL B TEMPERATtIRE FOR ASFRAE LOCATION MOS{ STMILAR TO <br />INSTALLATIO\ LOCAIION LO!!ES' EXPECTEO AMBIENT TEMP I. C <br />NOTES FOR INVERTER CIRCUITS (Gurde Soctron 6 and 9) <br />1) IF UTIL Y REOUIRES} VISIBLE.BREAK SWTCH, OOES THIS SWTCH MEET THE <br />REOUIREMENT? YESE NOtr N/Atr <br />2) IF GENERAIION METER REOUIBEO, OOES THIS METER SOCKET MEET ThE <br />REoUTREMENT, YEs tr NozI N/ao <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />CURRENT ON NEC 690.53 SIGN OR OCPO RATING AT OISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING (Se. Guide Secton 9),4 <br />s) TOrAL OF - TNVERTER OCPD(S). ONE FOR EACH INVERTER DOES TOTAI <br />SUPPL.Y EREAKERS COMPLY WTH 120% AUSBAR EXCEPIION IN 690 64(BX2Xa)? <br />YES tr NOD <br />2) <br />MO <br />HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASI]RAE HIGHEST <br />Nrh 2'^ DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOSISJMILAR IO <br />TAL LATION L OCATION HIGHEST CONTINUOUS TFMPERATU RE -JII'CINS <br />N().IES I.OIT STn Nt)At{I) STITIN(; SYSI-EM II ICTRICAL DIACRAM <br />F <br />c <br />u <br />a <br />=2 <br />1 <br />i- <br />! <br />Srte Name _ <br />Srte Address <br />2 ) 2OO5 ASHRAE FUNOEMENTALS 2% DESIGN TEMPERATURES OO NOI EXCEEO <br />47OC IN THE UNITEO STAIES (PALM SPRINGS CAIS4,11OC) FORLESSTHAN9 <br />CI.JRRENT-CARRYING CONDUCTORS IN ROOF.MOUNTEO SUNLIT CONDUIT AT <br />LEAST O 5'ABOVE ROOF AND USING fHE OUTOOOR OESIGN TEMPERATURE OF <br />47'C OR IESS (ALL OF UNITED STATES), <br />a) 12 AU,iG. 90'C CONOUCTORS ARE GENERALLY ACCEPTAALE FOR MOoULES <br />WTH lsc OF 7 58 AMPS OR LESS VltlEN PROTECfED BY A l2-AMP OR SMALLER <br />FUSE <br />b) 1O A\^Is, gO'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MOOULES <br />WTH lsc OF 9 6 AMPS OR LESS WIiEN PROTECTEO BY A 15-AMP OR SMALTER <br />FUSE
The URL can be used to link to this page
Your browser does not support the video tag.