--SANTA <br />ANAJIiil* <br />Plannlng & Bulldlng Agenry <br />Bulldlng Srf.ty Dlvision <br />20 CMc Contor Plaza <br />P.O. Box 1988 (M-19) <br />Santr Anr, CA 92702 <br />(7la) 6/U.5800 <br />wuw.3rntr-rn!.org <br />RES!DENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />sol{1 cBc 2013 <br />Solar Photovoltalc (Pv) chockllrt for DGtached SINGLE FAlllLY RESIDENCES Only <br />lnrtructlon!: The licensed contracdor of rocord shall complete all sections, answer the ten qusstions and <br />sign the certificaflon section below. A copy of this form shall be attached to each of TWO sots of plans, of <br />minimum '11' x 17" siz€. lf an.werlnq NO to anv of tho queldon3, Dlan check shall be requlred. <br />Proj.ct Address:1728W PARK LN , Santa Ana CA 92706, United States <br />ConEactor Company Nam6:Solar CitySOLARCITY <br />ti8ft 1 04Contractor Llcen3e Number: <br />YES NO <br />tr tr1 <br />Aro the lollowlng apPllcabh to the propored proiect? <br />Will the PV systom layoul provido the requirsd three-foot wide clear access pathways <br />per Section 605.11 of the Callfomia Fire Code, and is this shown on th€ roof plan? <br />Wll the PV systom be installed on a rool having only one roofing layer with no <br />overlays? <br />Wll the PV array be flush mounted to the existing roof so that lho plan€ ol the <br />modules (panols) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system bo installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installod with a spaco of 2' minimum to 10" maximum between <br />tho underside of modules and the surface of the rooP <br />Wll the PV system bs installod without uslng any ballast Eystem or countor-weight <br />system? <br />Will the anchors be installed Mth a maximum horizontal anchor spacing of 6 feet <br />and is this maxlmum horizontal spacing shown on the plans? <br />Wll the minimum 5/16" lag screws be installed with a minimum of 2'112 inch <br />€mb€dment into roof rafters (with pre{rilled holes) and is this minimum embodment <br />sho rn on the plans? <br />Are ALL the structural pages of the plans WET slamped and sign€d by a Califomis <br />llcsns€d professlonal engineer? (including proiect spe<ific sito plan, PV layout, <br />anchorage spacing, anchorage dotails and manufac'ture/s PV support information.) <br />3 <br />4 <br />5 <br />A <br />7 <br />2. @E <br />I @tr <br />a Eltr <br />10 trB <br />I certlfy under penalty of porjury under the laws of the St te of Callfornla that the above 13 true: <br />print Name: JAIRO RIVERA Signature Jairo Rivera-Mendez fi#,?#l t?**' <br />phone Number: 4805538187 Dak- 6/27 /2016 <br />Eltr <br />troatr <br />Eltr <br />@tr <br />Rov: &i7,2015 <br />Emait Address: jriveramendez@SOLARC lTY. COM