Laserfiche WebLink
,--SANIA <br />NA <br />,Lt\I\C <br />&t{IJfi[ <br />ffi\0 <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box'1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-5800 <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />sol-o1 cBc 2013 <br />Solar Photovoltaic (PV) Checklist for Oetachod STNGLE FAMtLy RESTDENCES Onty <br />lnstructiona: The licensed contractor of record shall comdete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans. of <br />minimum 1 1 " x 17' size. lf answorinq No to anv of the quostions. plan check shall be reouirEd. <br />Proj ect Address: ' i:fuf+" *ft* Sa tia Nto. ,(A c )?D<- <br />4 <br />Contractor Company Name: STAR SUN SOLAR <br />Contractor License Number: 1 0 C I 3 C 2 <br />YES NO Are the following applicable to the proposed projoct? <br />Wll the PV system layout provide the Iequired three-foot wide clear access pathways <br />per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? <br />\Mll the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />\Mll the PV array be flush mounted to he existing roof so that the plane of the <br />modules (panels) are parallel to the ptane of the roof? <br />Wll the PV system weigh maximum 4 pounds per square feet or less? <br />Wll the PV system be installed where the modules do not o\€rhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Wll the PV system be installed with a space of 2" minimum to 10,, maximum between <br />the underside of modules and the surface of the roof? <br />Vvill lhe PV system be installed without using any ballast system or counter-weight <br />system? <br />Vvill the anchors be installed with a maxinum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Wll the minimum 5/16' lag screws be installed with a mlnimum ol Z-1t2 inch <br />embedment into roof rafters (with predrilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans WET stamped and signed by a Catifornia <br />licensed professional engineer? (including poject specific site plan, pV layout, <br />anchorage spacing, anchorage details and manufacturer,s pV support information.) <br />trtr <br />2 <br />3 <br />BD <br />tr <br />trtr <br />EID <br />trtrtrtr <br />trtr <br />trtr <br />6 <br />7 <br />I <br />9 <br />10 trtr <br />I certify under penalty of periury under the laws of the State of Califo <br />Print Name: STAR SUN SOIAR <br />the a <br />Phone Number: {714 ) 530-8177 <br />Signature <br />Datel q/38 / t) <br />Email Address <br />X <br />IN FOGSTARSUN SOLAR . COM <br />is true: <br />Rev 8/1712015