Laserfiche WebLink
I ) i • i ELECTRICAL PROVISIONS • GENERAL NOTES: 1. ALL 125-VOL T, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL: A. BATHROOMS B.OUTDOORS C. CRAWL SPACES· AT OR BELOW GRADE LEVEL D. KITCHEN -WHERE THE RECEPTACLES ARE INSTALLED TO SERVE THE COUNTERTOP . SURFACE. 2. AT LEAST ONE 20-AMPERE BRACH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. 3. ALL 120-VOL T, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPL YING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, BEDROOMS, CLOSETS HAt.LWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT-INTERRUPTER, COMBINATION-TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. 4. APPLIANCE RECEPTACLE OUTLETS INSTALLED IN A DWELLING UNIT FOR SPECIFIC APPLIANCES, SUCH AS LAUNDRY EQUIPMENT, SHALL BE INSTALLED WITHIN 6 FT. OF THE INTENDED LOCATION OF THE APPLIANCE. 5. DWELLING UNIT RECEPTACLE OUTLETS: A. SPACING· RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 1.8 M (6 FT.) FROM A RECEPTACLE OUTLET. B. SMALL APPLIANCES -IN THE KITCHEN, PANTRY, BREAK ROOM, DINING ROOM, OR SIMILAR AREA OF A DWELLING UNIT, THE TWO OR MORE 20-AMPERE SMALL-APPLIANCE BRANCH CIRCUIT REQUIRED BY 210.11 (C) (1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE OUTLETS COVERED BY 210.52 (A), ALL COUNTERTOP OUTLETS COVERED BY 210.52 (C), AND RECEPTACLE OUTLETS FOR REFRIGERATION EQUIPMENT. C. RECEPTACLES INSTALLED IN A KITCHEN TO SERVE COUNTERTOP SURFACES SHALL BE SUPPLIED BY NOT FEWER THAN TWO SMALL-APPLIANCE BRANCH CIRCUIT, EITHER OR BOTH OF WHIC~: SHALL ALSO BE PERMITTED TO SUPPLY RECEPTACLE OUTLETS IN THE SAME KITCHEN AND IN OTHER ROOMS SPECIFIED IN 210.52 {8)(1). NO SMALL-APPLIANCE BRANCH CIRCUIT SHALL SERVE MORE THAN ONE KITCHEN. D, WALL COUNTERTOP SPACES -A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL COUNTERTOP SPACE THAT IS 12 IN. OR WIDER. RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24 IN. MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THE SPACE. E. AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED IN BATHROOMS WITHIN 3 FT. OF OUTSIDE EDGE OF EACH BASIN.THE RECEPTACLE OUTLET SHALL BE LOCATED ON A WALL OR PARTITION THAT IS ADJACENT TO THE BASIN OR INSTALLED ON THE SIDE OR FACE OF THE BASIN CABINET NOT MORE THAN 12 IN. BELOW THE COUNTERTOP. 6. OUTDOOR OUTLETS: , \ A. AT LEAST ONE RECEPTACLE OUTLET ACCESSIBLE LOCATED AT GARDE Ll;i\,'.EL ANQ NOT MORE THAN 6 FT. ABOVE GRADE SHALL BE INSTALLED AT THE FRON1AND BACK OF THE DWELLING. , ; , . . .. . C' B. PORCHES THAT ARE ACCESSIBLE FROM INSIDE THE DWELLING,UNIT SHALi::. HAVE AT LEAST ONE RECEPTACLE OUTLET INSTALLED WITHIN THE'f-:E;RIMETER OFTHF ' •>., PLANS TO COMPl Y WITH THE 2013 EDITION OF THE CALIFORNIA BUILDING CODE (CBC), 2013 EDITION OF THE CALIFORNIA RESIDENTIAL CODE (CRC), 2013 EDITION OF THE CALIFORNIA MECHANICAL CODE (CMC), 2013 EDITION OF THE CALIFORNIA PLUMBING CODE (CPC), 2013 EDITION OF THE CALIFORNIA ELECTRIC CODE (CEC), 2008 EDITION OF THE CALIFORNIA ENERGY CODE (TITLE 24). OCCUPANCY: TYPE OF GONSTRUCTION: STORIES: EXISTING HEIGHT: LOT AREA: EXISTING LIVING AREA: NEW ONE STORY ADDITION: TOTAL NEW LIVING AREA: EXISTING TWO CAR GARAGE: EXISTING LOT FOOTPRINT: EXISTING ... OT COVERAGE: CONSTRUC:'ON -GENERAL R-3 / U-1 VB ONE +/-14' 6866 S.F. 938 S.F. 343 S.F. 1281 S.F. 368 S.F. 1649 S.F. 24.0% 1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CL.:::AR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES { POWER POLES, l:'JLL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES. (ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHE;:a OR NOT THE LINES ARE LOCATED ON THE PROPERI'!. FAILURE TO COMPLY MAY CAUSE CONSTR:..:CTION DELAYS AND/OR ADDITIONAL EXPENSES. 2. AN APPR'.:VED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALL:.C:;:> ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNEC'iED TO THE EXTERIOR OF THE BUILDING OR STRUC"\.:RE CONTAINING THE FUEL GAS PIPING.• (PER ORD!NANCE 170,158 AND 180,670) SEPARATE PLUMBl"i.3 PERMIT IS REQUIRED. I -4>" iii [;:l 0 :i, ~ If) EXISTING WATER METER EXISTING Gf!.5 METER ,,,,,_~_,;,_--•,,r,•.,.,~ ,,-,,,. "'. :;f. ,,,.,, ,1 · ~ .. f_'J• . in ~ .. . 0' .1 . . . : i SITE PLAN SCALE: 1 " = 1 O' -0" ,,, "'-"•• -~"""· ,·,, ,> ·""'' ,cc.a·,•." .'-:<:; ~ COMMERCIAL ST. ,EXISTING G' HIGH WOOD FENCE (N) 23'-3" (N) 20-0" 18'-G" O.H. FROJECTION . ·\.,' •... c;ITY SIDE)VALK ___ ....,....; -1--/-=~---\)-~~ ,✓ I ..a,,C,~ 1/ / !' "-' 0 z "-' ?;i9 olfl iii :\;I \LI~ z-0~ (')IL ~~c· 115 lfl . ...,...., !co• ~I / \ /7:7 / //// // / // /1[1~/1////// /~. . ////'////// // ,/,/((/✓,' /i / J /// NEW,0),~5 RY/) /j/ X// /ApDJff. 90N· i,'(JS,,l" J / .·/// //// i...,,,.., ......... .,...~ ....... "'!,~· ~/ / /// / / /~~~::> .. /,/ /~/;~/ /□llL--./U"I .~ j . ·:;::·. s . •.<( 3 rn . l \):ce,~: / -0.V:\! 5,.,, 1 EXISTING / o'1~'f::'; .,.. I FOWER _J c!S;,,0,.. ,.. FOLE ~0/1/ / 1/ -..-, .J .J ;§ >L ~ !O ~ :i:: to (') z I I I ~ I I l -q~.-.--l. -·:-"'·'"'·:c;.\15·-·' .. · .. 42-~'·"':"'· I '""'-'"""'"'""""~ . ..:f, ·o· . EXISTING .o•.i=. : : II u .••• ··•· .··:,. ,.. • -. ,. · · ·eDIBON · • u · · I .. ,. • .. , ·'· ··• tii ~ • · g · · METER. ; ~ · EX1~r1NG DRJyeWAY 1 ·.• .. :.· .. · .. ·· •. · .. ·· .. Yv: j ·F tt..: \. . IIQ.11.' ;.;..•~••• . •·1,• o, V'l,, . ,\:,11:;iJING .$' rllGti BhOCK WALL l\1 I.... I . .I ' ' '·"'··•·;y,.< .,;,, : ·,I',-·, .: ·,,•:.·,,.,_) \.,·-.. b ""/.~/'' ,.,./ d ... ( , ;" / ·V·, . ' X ~--...,r-v·---,/·"C~. ·•··.. . ,.,..., ;_-,;···,_,:,:·.·_ . ·•% / . . . . ... . ' ( WINDOW LEGENO . \ . ,.,., PORCH, THE RECEPTACLE SHALL NOT BE LOCATED MO.~e THAN f:l'-6" ABOVE Tl,f~ ..... . PORCH SURFACE. <''' . · ·.•. .. .. . ' 7. HALLWAYS OF 10 FT. OR MORE IN LENGTH SHALL HAVE AT LEAST ONE RECEPTAC:l!:: 3. PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEVt' CONSTRUCTION. EXISTING SHOWER HEADS Ar,!D TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION ;:-,, ;:·:,:. ;: i ; ·_,; . +i1(,, €7+~4'1/ .... •.• . ~•7'7 . .. \/.[. f;1 ....... . j ~ ;!~;~~1M. 11~14l vERT1c~ .. ·· ... •. IM. 1r) . . ' '· •. ,·:; . ·· .... ( FEET ---1 -INCHES . · . . : • \. INCHES--~ L-FEET . ·.·.·. 1 r /J.l,, 1.__ .· , : . ·;.c_;/ ]l-{3 q7 0-~=t,.un '-~ / '' \• -"/') 1 -~, ~ "-.../'-/-l .. ,,,,\cJl:.Gc•s,,11 riv,--rz; --._,__.,.--..,__,/ ) . ; " OUTLET. I, UV!NGROOM '"\ j DINING ROOM ~ u ==,-.---,_J' I I ~ KITCHEN & @u· ~ ,' ~!. sa-nr---.. 1 7, j BEDROOM \ • -e13-· ~ ~ \ BATH ) BEDROOM EXISTING FLOOR PLAN SCALE: 1/8" = 1'-0" ,I ~ N LEGEND EXIST WALL [-· ··--· '] ~ ~-~-"' -·-WALL TO BE REMOVED !II ,, Ii 1-LIVING ROOM \ _ _J Ii \MOVEWAUS\ ll CC:.C'Cl Ji u , r 7. BEDROOM i 6 BATH DININ<, ROOM ) & 0'H l<JTCHEN @ t BEDROOM )1 "o -.. 0 r--.,1 ·~ s l': ~ -, I -~ .. "\ I:::::! I F ➔ 'i REMOVE CONG. 5TEP5 -/2 j_ FRAME.IN DOOR DEMO FLOOR PLAN SCALE: 1/8" = 1'-0" .. ,i,e:7) ~ ... ·-=·•····''···· 1. . 23'<3• Vl/Lc\;¾c)~-'-. I C.ft1l =·A B'~O'' 14'~5" ♦ 0 ::§::AFI ::g::GFI ::g::~ $ $3 (§ @) []] t::x,Z,;;J}J~J:c-;+l;'.;~:] NOTE: LEGEND ' SURFACE-MOUNT FLUORESCENT LIGHT · ·• RECESSED FLUORESCENT LIGHT ARC FAULT INTERCEPTOR GROUND FAULT INTERCEPTOR WATER PROOF GROUND FAULT INTERCEPTOR LIGHT SWITCH 3-WAY LIGHT SWITCH Ul217RATED SMOKE DETECTOR BATTERY OPERATED UL 2034/2075 RA TEO CARBON MONOXIDE ALARM BATTERY OPERATED EXHAUST FAN/ AIR MIN, 60CFM EXIST WALL NEW 2X4 STUD AT 16" O/C /I C;,,L. .• ··' i.,,\,-1 . ·. ·.· I y i/\ .;~·'t}'f·.· 1. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. 2. IN EXISTING DWELLING UNITS A CARBON MONOXIDE ALARM IS PERMITTED TO BE SOLELY BATTERY OPERA TED WHl:RI: REPAIRS OR ALTERATIONS DO NOi RESULT IN THE REMOVAL OF WALL AND CEILING FINISHES OR THERE IS NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAWL SPACE. I ~··"-•--·-----· ~1 4' O" ····f;· (N) 3044 5H ....... -· . .... (E) 3044 5/i ,f-·---=---· -i . · ···· · · -.r;:. · 1 i • £· ) ·7-;·t . (N) 2030 511 I · re_, 7' I I 4f I L0::1 rEMP. GL. AFI ''•:zit-'.r,·1::~i:':-.-~_?:,i"l1'~:"./·,;· ::re; :-:::;c.:.:•.:·,:::"::·.-~'.:':i ,,, .. <!1>Afl 'ti'Afl bLI C,7 'YI 11. REMODELED BEDROOM~lAfl LJ ~ m c. k:1 9 .. 1 I o--------... --·-~ \ ,.,.--,-• N•~ •+H •"-I r-1 II i22"X30"7 ' 2•.eJ, I i ATTIC i I NEW MASTER BEDROOM I i <f'\ I LACCE~5.J-/ 1.:.il I OL1 I 11 ~ I 1NEW 7 I II 6 I 1CLS / (N) 28GIJ HC I I I l f.J \ --.-------. jJ. ' ; ) EXISTING LIVING ROOM ® / r~ / ~~J \ if/ ~AF! ~ A~ A~i• •· ···r·•c---..\ I : I ; .. ' :, ' .. · I ------......._..___ /~ 0---·-···v "' l·t ·+>·········•·····••P•< . ' .... \ A"I I --0---•. _ ~ NEW ~LL __ J,~ 5,4,@§) j, ----0-\ '\ ® j' :r ..J "' , ... ,. I I 's (NJ GOG8 TEMP. Gl. j (NJ 28G8 H . ; '-<{ :c <I) . ,,. -.. ,,. ·' 0 iD "1 -0) ·' ... g 'I I I, J, • , •. ~---~ , . t!J lv1.c/C (r '!.-~H-.===~===;-H~'{',~l~ID~IN~G,li;D~OO~R~~=P:i>~3 lui~~~C½l~;;:;:;:.:;:;;z;:;:gzz~~=:.it2:=:::z::::::::····d3· 4---'C iw (N) ,----.c;::,.."""',-----, u,:;< ;' 11. (N) 3040 SH ----" r, ~ ~ I ruN_,__~~\.::Y~o~~-f,; 04 b 5~ \EXISTING BATH r· .'c<:'t: :c: ,,J'Fl•'''·"7·· -:I l ~ EXISTING DINING ROOM 1..--r-: -~-..LI~} IT?ll i :gu ~ ~ g I( )IJ e•.o· j, I '!:) lu 1-1!/:.:!. ....., ---; I TT I II I 11 .J -jJ -,-1 ~ .J ;\ ' EXISTING KITCHEN I I EXIS'f!NGi ~'\ I ATTIC I (E) WH L ACCE55_J w l:lf;Z Zo l-z ~~ ,-71 1i;--111 ![__JI! ~==tl I I I 00'" F.:> r5 ••• o --=.]Ir" r ", I ""' -._.,_J r': ill L_. I . 'I I, L_-11 ,, ® r EXISTING BEDROOM <I) g 23'-3' _l ~ "' g NOTE: NEW FLOOR PLAN SCALE: 1/4" = 1'-0" 1. ALL WINDOWS SHAL.L MATCH IN EXISTING WINDOWS IN MATE:RIAL ANO Mf,;THOO OF 01'!:RATION. 2. ADD WOOD TRIM AND SILL TO NEW WINDOWS TO MATCH EXISTING WINDOWS. 3. ALL NEW WINDOWS SHALL MATCH EXISTING WINDOWS HEADER HEIGHT. ---"~} z (!) -(/) UJ 0 ~· >-(!) Z~o <( I-1-(!) LL -~i:2?5 ~ :a: 0 ~ :g ~ \~-~ 0 w ;=: ~ t CJ O >-z <I'. :::, zzwUN z .A' :; • ::g > ..... <( 0:: 0:: -> z (!) <I'. !;!;! u.i <( 0:::: <( ~ I= z 0:::: UJ -~ :r: 0 OLL~~s 5: ·\ u.i ~ Cl u. ~ Cl ~ (!) (/) z z ::i: ::iZ~ a. 0 u. 0:: t; (!) Owz ocn-...J ...J LL Cl UJ (I) oz Uz z <I'. "<f' <((/)Z_J z O Cl. z O i= . , ::i I-Q<l'. ~ (/) (/) N'Sl' '<t ll.<( _..J..J N X >Z:::i:<l'.<(UJUJ UJ~ l:! UJ :::, <I'. I-I--' ...J "-....JOO::WWl-1-0 (/) liJ LL U. 0 Cl I-1-z ~c--..i'l'""' ._NV'V ..J,...:,.1 1,<:-;JN .._.._(I) 001-f-'.. '<t ~ '° ~ LL (/) (0 (0 Cl') •· ~ z N 0 t; -~ I-' l-o 1-r-t) M LL ~ 0 WOzwco O { w"'-->N <( 0:: Sj 0. <I'. 0, <( . • >-~5505(05 \ i ,v <( 0:: 0:: • o O '-../·1 u.. u<(<!JOZ~...J , Q >-Z (.)Q<000~ V'• I-cn<I'. ~ z0!:; cb u. <;> 1! ·<(UJ u..OO<t . (/) (f.) I-z (.) ~ ~ r-1:S ---..,: T"""'zz <0....3cr>1-, UJ o...-~ N I.O m"'""'LU<'?=>('t')QT"""C"l ! 2 :(/) l(.'. ;I.I.. ...,...1 Cl Cl: \N Q (f.) .. (/) .. I S UJ o:: w w.. .. (.!) ---: w ...Jz . 0:: Z 0:: OZ <( " -(-...__. I LUO :::,.0 (!JZZ~ Zo 0>c:i ::i::wo.o <( <( ll.J<(N -· A-1 ---~--·