Plannlng & Building Agency <br />Bulldlng Safety Division <br />20 Civic Cantor Plaza <br />P.O. Box 1988 (il-l9) <br />Santa Ana, C^^92702 <br />(714) 647-5800 <br />www.aanta€na.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />sol-01 cBc 2013 <br />Solar Photovoltalc (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed conlraclor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11" x 17" size. lf answqrinq NO to anv of the questions. plan check shall be required. <br />Project Address:2513 Larchmont Ave, Santa Ana, CA 92706 <br />Contractor Company Name . Tesla Energy Operations <br />Contractor License Number .888104 <br />YES NO <br />EltrI <br />2 trtr <br />atr <br />Eltr <br />@tr <br />trtr <br />Elo <br />Are the following applicable to the proposed project? <br />Will the PV system layoul provide the required three-foot wide clear access pathways <br />per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panols) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds par square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2' minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV syslem be installed without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch <br />embedment into roof rafters (with predrilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans WET stamped and signed by a Califomia <br />licensed professional engineer? (including proiect specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />4 <br />5 <br />6 <br />7 <br />8 trtr <br />9 @tr <br />10 trtr <br />I certify under penalty of periury und6r lhe laws ol the State of rnia that the <br />print Name: Melissa Foxx Sign <br />phone Number: 7 02-7 85-2998 <br />Email Address <br />8 <br />R6v:8/1712015 <br />. mfoxxsarmiento@tesla.com <br />5/tt <br />ls true: <br />*-SANTA <br />ANAJIiH* <br />Date: