Laserfiche WebLink
**SNTA <br />NA,Iffi <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Cenler Plaza <br />P.O. Box 1988 (M.19) <br />Santa Ana, CA92702 <br />(714) 647-s800 <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />soL-o1 cBc 2013 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Onty <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 1 1" x 1 7" size. lf answerinq NO o anv of the ouestions. olan check shall be required. <br />Project Address: <br />Contractor Comp any Name: <br />Contractor License Number: <br />a__ <br />L- !/;/+ssai7- <br />YES NO1Eltr <br />2qtr <br />,?J <br />4 EItr <br />s Elfl <br />6 €Ftr <br />z (Eltr <br />8 EItr <br />e €tr <br />,04 <br />Are the following applicable to the proposed project? <br />Will the PV system Iayout provide the required three-foot wide clear access pathways <br />per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to 10' maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ba ast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans stamped and signed by a California <br />licensed professional engineer? (including project specillc site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's support information.) <br />I certify under penalty of perjury under the laws of the Stat of true <br />O /rJ <br />tr <br />?,+l-. t l{n ws Signature <br />Date:Phone Number Q;7a.--.r=O / *B115.6 <br />ove I <br />Email Address: ?av tn z-Zeo.c'NeeL1,.) (C-^) Lcl\1 <br />Rev 11/19/2015 <br />Print Name: