My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20173055 - Permit
PBA
>
Building
>
Permits
>
W
>
Westwood Ave
>
2121 N Westwood Ave
>
20173055 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2021 12:10:21 PM
Creation date
6/1/2021 12:10:20 PM
Metadata
Fields
Template:
Permit
Permit Number
20173055
Full Address
2121 N Westwood Ave
Permit ID
273883
Master ID Number
2021-165270
Project Name
Miscellaneous Counter1 Permit
Street Number
002121
Street Direction
N
Street Name
Westwood
Street Suffix
Ave
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
4/1/2021
Issued Date
4/1/2021
Finalized Date
4/9/2021
Flood Zone
X-0602320144J
Description of Work
Installation of roof mounted PV system. Worksheet attached to plans. All fees paid on #101106313
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />lslK.lmur Or -2 <br />CGt i/t .. CA 92626 <br />Site Name:Ddnt H..o!@k <br />Site Address: ztzt tt w6n ood Aw. s.nt an! ca 92705 <br />System AC Sizo:8.s2 <br />NIS <br />SIGNS-SEE GUIDE SECTION 7 <br />NOTES FOR ALL DRAWNGS SIGN FOR DC DISCONNECTPV MODULE RATINGS @ STC (Guide Section 5) <br />MODULE MA(T Qcells <br />MODUTE MOOEI Q.PEAK DUO BLK ML.G9+ <br />MAX POWER-POINT CURRENT (l,gP)10.04 <br />MAX POWER.POINT VOLTAGE (VMP) <br />oPErrctRcurT voLTAGE (vo.) <br />37.85 <br />45.04 <br />SHORT-CIRCUIT CURRENT (IS) <br />MAX SERIES FUSE (OCPD) <br />10.5 <br />20 <br />MAXIMUM POWER (PN)284 6 <br />MAX VOLTAGE (TYP 6OOVDC)35.96 <br />VOC TEMP COEFF (mV/Ct or %fctr)-0.27 <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NAT|oNAL ELEcTRtcAL cooE REFERENCES <br />sHowN AS (NEC )Ofi)O9 <br />No sign necessary since 690.51 <br />marking oa PV module covgrs <br />n6€dod information <br />INVERTER RATINGS (Guade section 4) <br />En hase <br />SIGN FOR INVERTER OCPD ANO AC <br />orscoNNtcT (rF usED)INVIRTER MA(E <br />INVERTER MOOTL IOTPLUS-72.2-US <br />MAX OC VOLT RATING 60v <br />MAX POWER @ 40oC 295VA <br />NOMINAL AC VOLTAGE 211-264 V <br />MAX AC CURRENT 1 .21 <br />204 <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />IF COEFF SUPPLIED. CIRCLE UNITS MAX OCPD RATING <br />NOTES FOR INVERTER CIRCUITS (Guid6 Seclion 8 and 9): <br />1,) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION, LOWEST EXPECTEO AMBIENT TEMP <br />1) IF UTILITY REOUIRES A VISIBLE.BREAK SWITCH, OOES THIS SWITCH MEET THE <br />REQUIREMENT? YESO NOtr N/Atr <br />2) IF GENERATION METER REQUIRED, DOES TIIIS METER SOCKET MEET THE <br />REOUIREMENT? YES tr NO tr N/Atr <br />3) S|ZE PHOTOVOLTATC POWER SOURCE (DCl CONDUCTORS SASEO ON MAX <br />cURRENT oN NEc 690.s3 stcN oR ocpo IAiNG AT otscoNNEcr <br />4) S|ZE TNVERTER OUTPUT CtRCU|T (AC) CONDUCTORS ACCORDTNG TO TNVERTER <br />OCPD AMPERE RATING. (S.. Guldc Sec1rcn 9) <br />2,) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% ORY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATIONLOCATION,HIGHESTCONTINUOUSTEMPERATURE "C <br />s) TOTAL OF _ INVERTER OUTPUT CIRCUIT OCPO(S), ONE FOR EACH MICRG <br />TNVERTER ctFcuill DoEs rorAl supply BREAKERS iciMply wtrH i20% BUSBAR <br />EXCEPTION lN 690.64(B)(2Xa)? YEStr NOtr <br />AC OUTPUT CURREN'T 28.7 A <br />NOMINAL AC VOTIAGE 120-240 <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />: <br />F <br />c- <br />do <br />Uo <br />c- <br />L <br />zcl <br />c- <br />C <br />F <br />x <br />- <br />NOTES FOR ARRAY CIRCUIT WRING (Guid6 S.ction 6 and 8 and Appendi E): <br />2.) 2OO9 ASHRAE FUNDAMENTALS 2% OESIGN TEMPERATURES DO NOT EXCEEO <br />47"C rN THE UNTTED STATES (PALM SPR|NGS, CA rS 44.roC). FOR LESS THAN I <br />CURRENT.CARRYING CONDUCTORS IN ROOF-MOUNTEO SUNLIT CONDUIT AT <br />LEAST 0.5'ABOVE ROOF AND USING THE OUTOOOR OESIGN TEMPERATURE OF <br />474C OR LESS (ALL OF UNITED STATES), <br />a) 12 AwG, 90'C CONOUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />wlTH Isc OF 7,68 AMPS OR LESS WHEN PROTECTED AY A 12.AMP OR SMALLER <br />FUSE, <br />b) 1O AWG. gO.C CONDUCTORS ARE GENERAI.LY ACCEPTABLE FOR MODULES <br />w|TH lsc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A ISAMP OR SMALLER <br />FUSE, <br />NOTES FOR MICRO-INVERTER ELECTRICAL DIACRAM
The URL can be used to link to this page
Your browser does not support the video tag.