Laserfiche WebLink
Norns FoR STnNDARD SrnINc Sysrnpt ELECTRIcnI DIAGRAM <br />Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />Contraclor Name, <br />Address and Phone: <br />ESP Contrading <br />970 W 190Th Sl Torao@ CA 00502 <br />Site Address: rB2BwsraNNE pL saNra ANA cAezq <br />System AC Size: ,u,'* <br />Site Name:ROSERT <br />Drawn By: <br />SIZE FSCM NO DWG NO REV <br />Checked By: <br />MODULE MAKE HANWHA Q PEAK <br />MODULE MODEL DUO-Gs 315 <br />MAX POWER-PO|NT CURRENT 0MP)9.55 A <br />MAX POWER-PO|NT VOLTAGE (VMP)32.98 v <br />oPEN-CtRCUtT VOLTAGE (Voc)39.87 v <br />sHoRT-CtRCUtT CURRENT (tsc)10.04 A <br />MAX SERIES FUSE (OCPD)20 A <br />MAXTMUM POWER (PMAX)315 w <br />MAX VOLTAGE (TYP 600Vm)480 v <br />VOC TEMP COEFF (mV/oCE or o/o/oC @)20c <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />SIGNS-SEE GUIDE SECTION 7 <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />NOTES FOR ALL DRAWNGS: <br />OCPD = OVERCURRENT PROTECTION DEVTCE <br />NATIONAL ELECTRICAL CODEO REFERENCES <br />sHowN As(NEC,(X.W) <br />INVERTER RATINGS (Guide Section 4) <br />NOTES FOR ARRAY CIRCUIT WRING (Guide Section 6 and 8 and Aopendix D):NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />1.) LO\A/EST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMII-AR TO <br />INSTALLATION LOCATION. LO\A/EST EXPECTED AMBIENT TEMP o oC <br />2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. HIGHEST CONTTNUOUS TEMPERATURE g_"C <br />2.) 2OO5 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED <br />47oC tN THE UNTTED STATES (PALM SPR|NGS, CA tS 44.1oC). FOR LESS THAN I <br />CURRENT-oARRYING coNDUcToRs IN RooF.MoUNTEo SUNIIT coNDUIT AT <br />LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47OC OR LESS (ALL OF UNITED STATES), <br />a) 12 A\4T3, gOOC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH lsc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE, <br />b) 1O AWG, gO'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WTH Isc OF 9.6 AMPS OR LESS W{EN PROTECTED BY A 1s-AMP OR SMALLER <br />FUSE. <br />1) lF UTIL|TY REOUTRES A VtStBLE-BREAK SWTCH, DOES TH|S SWTCH MEET THE <br />REQUIREMENT? YES EI NO tr N/A tr <br />2) IF GENERATION METER REOUIRED, DOES THIS METER SOCKET MEET THE <br />REOUIREMENT? YES tr NO tr N/A EI <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) S|ZE TNVERTER OUTPUT CIRCUtT (AC) CONDUCTORS ACCORDTNG TO TNVERTER <br />OCPD AMPERE RATING. (See Guide Section 9) <br />s) TOTAL OF_ INVERTER OCPD(s), ONE FOR EACH |NVERTER. DOES TOTAL <br />SUPPLY BREAKERS COMPLY WTH 120% BUSBAR EXCEPTTON tN 690.64(B)(2)(a)? <br />YES E NO T] <br />INVERTER MAKE SOLAREDGE SE <br />INVERTER MODEL 60OOH-USRGM <br />MAX DC VOLT RATING 32v <br />MAX POWER @ 4O'C 480 w <br />NOMINAL AC VOLTAGE 20v <br />MAX AC CURRENT 25 A <br />MAX OCPD RATING 30A <br />PHOTOVOLTAIC PO\A/ER SOURCE <br />RATED MPP CURRENT <br />RATED MPP VOLTAGE <br />MAX SYSTEM VOLTAGE <br />MAX CIRCUIT CURRENT <br />WARNING: ELECTRICAL SHOCK <br />HAZARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />SIGN FOR INVERTER OCPD AND <br />AC DTSCONNECT (tF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />AC OUTPUT CURRENT 35A <br />NOMINAL AC VOLTAGE 240 v <br />THIS PANEL FED BY MULTIPLE <br />souRcES (uTtLtTY AND SOLAR) <br />SCALE NTS Date:SHEET <br />(r) <br />U <br />F <br />'J1 <br />\/) <br />cl <br />CL <br />t/) <br />U <br />Uocc- <br />F <br />./ <br />Uc- <br />ouF <br />ou <br />[J