Laserfiche WebLink
*,,SANTA <br />ANA-"ffi! <br />Plannlng & Building Agency <br />Bulldlng Safety Dlvislon <br />20 Clvic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, CA92702 <br />Qrlt) 647€8U) <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />soL-01 cBc2013 <br />Solar Photovoltaic (PV) Ghecklist for Detached SINGLE FAMTLY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11" x 17" size. lf answerlns NO to anv of the questions. plan check shatl be required. <br />Project Address:722 S. BIRCH ST, SANTA ANA, CA92701 <br />Contractor Company Name:SOUTHWEST SUN SOLAR, INC <br />contractorLlcsnse Number: 1004667 <br />YES NO Are the followlng appllcable to the proposed profect? <br />Wllthe PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.11 of the Califomia Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV anay be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the rooP <br />Will the PV system we(;h maximum 4 pounds per square feet or less? <br />will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />will the PV system be installed with a space of 2' minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />will the anchors be installed wilh a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontalspacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch <br />embedment into roof rafters (with predrilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans wET stamped and signed by a california <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, ancfiorage details and manufaeture/s PV support information.) <br />,l a tr <br />tsD <br />tstr <br />I certlfy under penalty of periury under the laws of the State of Galifornia <br />print Name: MlMl NGO Signature: <br />phone Number: 714 582 3909 Date <br />EmailAddress: <br />2 <br />3 <br />Btr <br />Etr <br />atr <br />tstr <br />Etr <br />atr <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. tsB <br />Rev:.81'|,712015 <br />PERM lT@SOUTHWESTSU NSOLAR.COM <br />is true: <br />Jt)