Laserfiche WebLink
Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />SOUTHWEST SUN SOLAR, INC <br />13752 I|ARBOR BLVD <br />GAROEN GROVE. CA 928,13 <br />Site Name: JOSE DOLORES GUZIJAN <br />site Address: 1048 W. CHESTNUT AVE, SANTA ANA. Cr' <br />System AC Size: 7 B <br />NT5 <br />SIGNS-SIE GUIDE SECTION 7 <br />NOTES FOR ALL DRAWINGS:SIGN FOR DC DISCONNECT <br />PV MODULE RATINGS @ sTC (Guide secrron 5l <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATtoNAt ELEcTRtcAL cooE REFERENcEs <br />sHow\ As rNEc )oo(.)o9 <br />MODULI MAXE <br />MODULE MOOEL <br />REC <br />REC32OTP <br />MAX POWER.POINT CURRENT (IMP) <br />MAX POWER.POINT VOLTAGE (VMP) <br />ls as <br />].,.t <br />OPEN.CIRCUIT VOLTAGE (V@)40.0 <br />SHORT,CIRCUIT CURRENT (S') <br />30 <br />320 <br />MAX VOLTAGE (TYP 6OOVOC)1000 <br />No sign nscessary sinco 690.51 <br />marking on PV module covers <br />needed information <br />INVERTtR RATINGS (Guide Sedion 4) <br />INVERTER MAKE Enphase <br />INV€RT€R MODEL rQ7-60-S-US (240V) <br />MAX OC VOLT RATING 48 <br />MAX POWER @ 40'C 240 <br />NOMINAL AC VOLIAGE 240 <br />'t .0 <br />30 <br />SIGN FOR INVERTTR OCPD AND AC <br />DrscoNNEcr (rf usED) <br />MAX SERIES FUSE (OCPO) <br />MAXIMUM POWER (PW) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />22 <br />NOMINALACVOTTAGE 240V <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR)0.76 MAX AC CURRENT <br />MAX OCPD RATING <br />NOTES FOR ARRAY CIRCI-IlT wlRlNG (G!do Section 6 and 8 and Appendx EI <br />1 ) LOWEST EXPECT AMBIENT TEMPERATURE BASEO ON ASHRAE MINIMUM MEAN <br />ETTREME DRY AULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSIALLATION LOCATION, LOWEST EXPECTED AMBIENT TEMP ]L"C <br />2 ] HIGHEST CONTINUOUS AMBIENT TEMPERATURE AASED ON ASHRAE HIGHEST <br />MbNTH 2% oRy BULB TEMPERATURE FoR ASHRAE LocATtoN Mosr stMtLAR To <br />INSTALLATIoN LocATIoN. HIGHEST CONTINUOUS TEMPERATURE 6L"C <br />2,) 2OO9 ASHRAE FUNDA ENTALS 2% DESIGN TFMPERATURES DO NOT EXCEED <br />.,.c IN THE UNITED STATES (PALM SPRINGS, CA IS 44,1.C), FOR LESS THAN 9 <br />CURRENT.CARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUIT AT <br />LEAST 0.5'ABOVE ROOF AND USING THE OUTOOOR DESIGN TEMPERATURE OF <br />47"C OR LESS (ALL OF UNITEO STATES), <br />a) 12 AWG, 90"C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MOOULES <br />wltH Isc OF 7 6A AMPS OR LESS WHEN PROTECTED AY A 12.AMP OR SMALLER <br />FUSE <br />b) 1O AWG, gO"C CONDUCTORS ARE GENERALLY ACCEPTAALE FOR MODULES <br />WI1H Isc OF 9,6 AMPS OR LESS WHEN PROTECTED BY A 15.AMP OR SMALLER <br />FUSE, <br />NOTES FOR MICRO-INVERTER ELECTRICAL DIACRAM <br />: <br />F <br />d.o <br />Uod <br />t: <br />c- <br />o <br />Lo <br />92703 <br />10.13 <br />vOC TEMP COEFF (mVfCtr or %fCD) <br />IF COEFF SUPPLIED. CIRCLE UNITS <br />NOTES FOR INVERTER CIRCUITS (Guide Soclon 8 and 9): <br />1) tF UT|L|TY REOUTRES A V|STBLE-BREAK SW|TCH, OOES THtS SWTTCH MEET TBE <br />REQUIREMENT? YES E NOD N/Atr <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REOUIREMENT? YES E NO O N/A tr <br />3) SIZE PHOTOVOLTA]C POI/YER SOURCE IDC) CONDUCTORS AASED ON MAX <br />c'URRENT oN NEc 690.53 stGN oR ocpo laiNG ar DtscoNNEcr <br />4) SrzE TNVERTER OUTPUT CTRCUTT (AC) CONDUCTORS ACCORDTNG TO TNVERTER <br />OCPD AMPERE RATING. (Se€ Guid6 S€ction 9) <br />5) TOTAL OF INVERTER OUTPUT CIRCUIT OCPD(S), ONE FOR EACH MICRO. <br />INVERTER CIFI-CUiT DoEs ToTAL SUPPLY aREAXERS ioMPLY wITH 120% aUSBAR <br />EXCEPTION lN 690.64(BX2Xa)? YESEI NoO <br />AC OUTPUT CURRENT