20170677 - Permit
PBA
>
Building
>
Permits
>
F
>
Fifteenth St
>
1919 W Fifteenth St
>
20170677 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2021 8:19:17 AM
Creation date
6/2/2021 8:19:15 AM
Metadata
Fields
Template:
Permit
Permit Number
20170677
Full Address
1919 W Fifteenth St
Permit ID
262665
Master ID Number
2020-157385
Project Name
Miscellaneous Counter1 Permit
Street Number
001919
Street Direction
W
Street Name
Fifteenth
Street Suffix
St
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
1/28/2020
Issued Date
1/28/2020
Finalized Date
2/18/2020
Flood Zone
X-0602320144J
Description of Work
Installation of roof mounted PV system. Worksheet attached to plans. All fees paid on #101102954
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXPEDITED PERMIT PROCESS FOR SMALL.SCALE PV SYSTEMS <br />STANDARD STRING SYSTEM <br />The information in this guideline is intended to help local jurisdictions and conrracrors identify when PV sysrem insrallations <br />are simple, needing only a basic review, and when an installation is more complex. Ir is likely rhar 50% -75% of all residenrial <br />sysrems will comply with rhese simple criteria. For projec6 that Fail ro meer the simple criteria, resolurion steps have been <br />suggested to provide as a path ro permir approval. <br />Required. Information for Pennit: <br />L Stte plan showing location of major componenB on the property. This drawing need nor be exactly to scale, bur it <br />should represent relative location of components at site (see supplied example sire plan) PV arrays on dwellings <br />with a f'perimerer space at ridge and sides may nor need separare fire service review <br />2 Electrical diagram showing PV array configuration, wiring sysrem. overcurrenr protecrion, inverter, disconnects, <br />requlred signs, and ac connecrion ro building (see supplied srandard elecrrical diagram). <br />3. Specification sheeG and installation manuals (if available) for all manufacrured components including, but nor <br />limired ro, PV modules, inverrer(s). combiner box, disconnects, and mounring sysrem. <br />Step 1 : Structural Review o[ PV Array Mounting System <br />Is the array to be mounted on a defined, permitted roof structure? Eyes Eno <br />U No due to non-compliant roo.f or a ground mount, submit completed worksheet lor the structure WKS\ . <br />Rooj lnformatioll: <br />t ls the roonng rype Iighrweighr (Yes = composirion. lighrweighr masonry, metal. erc )COMP SHINGLE <br />IJ No, submit completed worhsheet for rooJ structure WRSI (No = heavy mosonry, slate, etc ..) <br />2 Does the roo[ have a single roof coveringu Eyes n no <br />I.f No, submit completed worksheet Jor roof structure WKSI . <br />3 Provide method and type of weatherproofing roof penetralons (e.g flashing, caulk)Flashing <br />M ounting Sy st e1n Infoflnat ion <br />I Is the mounting structure an <br />beneath rhe module frames?ves E <br />neered <br />No <br />producl designed to mount PV modules wirh no more rhan an 18" gap <br />If No, provide details of structurq.l attachment certijed, by a destgn professional. <br />2. For manuFactured mounring systems, frll out information on rhe mounring sysrem below <br />a. Mounting Sysrem Manufacrurer @ Producr Name un6 51o6"14 Rock it <br />b. Total Weig <br />e <br />hr of PV Modules 3n4 36115 712.4 lbs <br />c Total Number of Attachmenr Poinrs 22 <br />d Weighr per Arrachmenr Poinr (b+O32.4 lbs(if grearer rhan 45 lbs.seeWKSl) <br />l\4aximum Spacing Berween Arrachment Points on a Ra <br />maximum spacing allowed based on maximum design <br />it 48 inches (see product manual for <br />Toul Surface Area of PV Modules (square feeo 246.5 <br />wind speed) <br />ftr <br />Disrributed Weight ol PV Module on Rool (b: 0 2.9 lb s/frr <br />II distributed weight of the PV qstem is geater thcn 5 lbs[t,, see WKSI . <br />Step 2: Electrical Review o[ PV System (Calculations for Electrical Diagram) <br />In order for a PV system to be considered for an expedited permit process, the following must appty: <br />l. PV modules, utility-inleractive inverters, and combiner boxes are identified for use rn PV systems. <br />2. The PV array is composed of 4 series strings or less per inverter <br />3. The total inverter capacity has a continuous ac power output 13,440 Watts or less <br />4. The ac interconnection point is on the load side of service disconnecting means (690.64(8)). <br />5. One ofthe standard electrical diagrams (El.l, El.la, El.lb, or El.lc) can be used ro accurately represent the PV <br />system. lnteractive PDF diagrams are avaiiable at www.solarabcs.org/permiming. <br />Fill out the standard electrical diagram completely. A guide to the electricat diagram is provided to help the appticant <br />understand each blonk to Lll in. Il the electrical system is more complex thqn the standard electrical dtsgram con elJectively <br />communicate. provide qn qlternatiye diagram with qryropia.te detatl. <br />2 pxprDrrED pERMlr I,RocEss FoR I,v sysrEMs <br />c <br />f <br />l
The URL can be used to link to this page
Your browser does not support the video tag.