My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10195377 - Permit
PBA
>
Building
>
Permits
>
G
>
Garnsey St
>
2600 S Garnsey St Unit# NA Bldg# B
>
10195377 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2021 9:42:56 AM
Creation date
6/2/2021 9:42:55 AM
Metadata
Fields
Template:
Permit
Permit Number
10195377
Full Address
2600 S Garnsey St Unit# NA Bldg# B
Permit ID
237908
Master ID Number
2018-141103
Project Name
JWC Environmental
Street Number
002600
Street Direction
S
Street Name
Garnsey
Street Suffix
St
Building Number
B
Unit Number
NA
Building Use Code
Warehouse
Job Types
Alteration
Permit Type
Building
Applied Date
1/24/2018
Issued Date
5/24/2018
Finalized Date
1/8/2019
Flood Zone
X-0602320259J
Description of Work
Remove and replace existing slab on grade.
Nature of Work
SOG Replacement
Document Relationships
10195377 - Plan
(Plan)
Path:
\Building\Plans\G\Garnsey St\2600 S Garnsey St Unit# NA Bldg# B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SPECIAL INSPECTOR REPORT <br />E DAILY tr WEEKLY tr FINAL <br />Report Date 064{-2018 Euilding permir * l0l 95377 City of Sanla Am CA Districi Offre I <br />Job Address 2600 S Gamse\ A\e Sa a Ara CA <br />Location on site warehouse T&I Al rEurr of sitc <br />Descripti on of wofi Obseri'e and inspcct installation of # 4 ban as dowels into existing concrete slab & footings $.ith 6" min <br />embed@ 12" oc. 5,15 total . Using Simpson Ser )(P Epoxy ro ICC ESR2508ard LARR 2574,1e\?. date 09-2019 \lith the <br />holes blown out and brushed clean prior to inshll. \€ri! materials . Iocations. and workmarship. All work to 2016 CBC code <br />ard guidelines. <br />Discrepan 6u" None <br />All wotk on lhis job T satisfactorily completed in conformance with the approved plans and <br />requiremen ts of the g Code <br />Signature tD#P028287 931s 06{4-2018 <br />P.inl Full Name KiIk Mosher LADBS # P02828 ICC#51731{2 Daytime Phone I (714) 719-8957 kmosh-@.,y mail com <br />6"*131 6onl1E6or Ouner builder /JMC oncrete & Masonry Ehgineer of Record Maum T Aziz # C 76916 <br />lnspec{ion Frequency: E Continuous D Penodic <br />Type of lnspeclion: O Reinforced Concrete D Gunite / Shotcrete O Presiressed Concrete O Masonry <br />Fot any of above types of lnspections provrde D6ign Mix <br />- <br />PSI- <br />! wetdlng I BiglFslrength Bolts E Epoxy I Ottrer_
The URL can be used to link to this page
Your browser does not support the video tag.