Laserfiche WebLink
Planning & Building Agency <br />Building Safety Oivision <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-5800 <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />sol{1 cBc 2013 <br />*-SNTA <br />NA <br />ll"r\1t\*C <br />t8flI[C <br />$[n <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />Pro,iect Address:2308 NORTH OAKMONT SANTA ANA, CA92706 <br />2 <br />3 <br /># 1038376, B <br />tr <br />trtr <br />trtr <br />YES NOEtr <br />Etr <br />Etr <br />trtr <br />Are the following applicable to the proposed proiect? <br />Will the PV array be flush mounted lo the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 3 pounds per square feet or less? <br />Will the PV system be installed where lhe modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to l0" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV system layout provide a three-foot wide clear access pathway per the <br />latest edition ol "Guideline for Fire Safety Elements of Solar Photovoltaic Systems" <br />by OCFA? (Guideline available on the OCFA website: http://www.ocfa.oro) <br />Do the plans show a maximum horizontal anchor spacing of 6 feet? <br />Do the plans show a minimum ol 2-112inch lag screw embedment into roof rafters? <br />Are ALL the structural pages of the plans WET stamped and signed by a California <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV supporl information.) <br />4 <br />5 <br />6 <br />7 <br />8. Etrs Eltr <br />1O EIE <br />I certify under pe <br />Print name: <br />nalty of periury under the laws of <br />-IGf€I;- /,r c., / tu. L*. 5 | <br />the State of California that the above is trueI <br />o5- <br />Signature: <br />12020 <br />x <br />Re\r:211712015 <br />t^ <br />Dale <br />lnstructions: The licensed contractor of record shall fill in the address of the project, contractor's <br />licensing information and answer questions 1 -10 below. Complete and sign the certification section.**lf answering NO to any of the questions, plan check shall be required.** <br />Contractor Company Name:CI,EAN INITIATIVE LI,C <br />Contractor License Number: <br />Phone Number: <br />Email Address: