20170557 - Permit (2)
PBA
>
Building
>
Permits
>
C
>
Cedar St
>
2138 S Cedar St
>
20170557 - Permit (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2021 12:00:13 PM
Creation date
6/2/2021 12:00:12 PM
Metadata
Fields
Template:
Permit
Permit Number
20170557
Full Address
2138 S Cedar St
Permit ID
262165
Master ID Number
2020-156993
Project Name
Miscellaneous Counter1 Permit
Street Number
002138
Street Direction
S
Street Name
Cedar
Street Suffix
St
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
1/9/2020
Issued Date
1/9/2020
Finalized Date
2/4/2020
Flood Zone
X-0602320278J
Description of Work
Install roof mounted solar panels. FEES PD ON 101102798.
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOTES FOR STANI)ARI) STITINC SYSTIM ELECTRICAL DIACRAM <br />Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />Site Address: <br />System AC Size <br />Sile Name <br />NIS <br />PV MODULE RATINGS @ STC (Gr/ido Seclion 5) <br />MoDULE MAKE Hanwha Solar <br />MoDUrr- MoDLL O.PEAK BLK-GS 315 <br />MAx powER-porNT CURRENT (tMp) 9.41 a <br />MAx powER-porNT VoLTAGE (vrp) 33.46 v <br />oPEN,ctRCUtr VoLTAGE (vd ) 40.29 v <br />sHoRT,crRCUtr cuRRENr (ts.) 9.89 a <br />MAx sERTES FUSE (ocPo) 20 A <br />MAXTMUM PowER (Pu,) 315 w <br />MAX voLrAGE (TYP 6oovc ) 1000 v <br />VoC TEMP coEFF (mV/'CEJ or %PCn) -0.28 <br />IF COEFF SUPPLIED CIRCLE UNITS <br />NOTES FOR ALL DRAWINGS <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODEO REFERENCES <br />sHowN AS (NEC XXXXX) <br />SIGNS-SEE GUIDE SECTION 7 <br />SIGN FOR DC OISCONNECT <br />PHOTOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT NA A <br />RATEo MPP VoLIAGE NA V <br />MAx sYsrEM voLrAGE . NA v <br />MAx crRcutrcuRRENT . NA A <br />WARNING: ELECTRICAL SHOCK <br />HAZARD+INE ANO LOAD MAY BE <br />ENERGIZEO IN OPEN POSITION <br />INVERTER RATINGS (Guide Section 4) <br />INVERTER MAXE SOLAR EDGE <br />TNVERTERMoDEL SE3000H-US <br />MAx DC voLT RATTNG 48 <br />MAx PowER @ 4o.c 3.8 <br />NoMTNAL AC VoLTAGE .240 <br />MAx Ac CURRENT 13.75 <br />MAx ocPD RATTNG 15 <br />SIGN FOR INVERTER OCPD ANO <br />AC DISCONNECT (IF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />NOTES FOR ARRAY CIRCUIT wlRlNG {Gurde Seclron 6 and I and Appendrr D) <br />1 ) LOWEST EXPECT AMBIENT TEMPERATURE AASEO ON ASHRAE MINIMUM MEAN <br />EXTREME DRY AULA TEMPERAIURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION LOWEST EXPECTED AMBIENT TEMP .c <br />AC OUTPUT CURRENT <br />NOMINAL AC VOLTAGE <br />15.83 <br />240 <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />NOTES FOR INVERTER CIRCUITS (Gurds Seclron 8 and 9) <br />1)IF UTILITY REOUIRES A VISIELE.BREAK SWITCH, DOES THIS SWITCH MEET THE <br />REOUIREMENI? YES O NOtr N/AI <br />2) IF GENERATION METER REOUIRED. DOES THIS METER SOCKET MEET THE <br />REOUIREMENT? YES O NO f] N/A tr <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (OC) CONDUCTORS EASEO ON MAX <br />CURRENI ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4)SIZE INVERTER OUTPUI CIRCUIT (AC)CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING. (566 Guide Seclion 9) <br />5) TOTAL OF INVERTER OCPD(S) ONE FOR EACII INVERTER DOES TOIAL <br />supply BREIREFS coMply wrrH 1zbio BUSBAR ExcEpfloN rN 690 64(aX2Xa)? <br />YES O NO E] <br />2,) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2'l" DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR IO <br />INSTALLATION LOCATION HIGHEST CONTINUOUS TEMPERATURE 1L"C <br />2,) 2OO5 ASHRAE FUNOEMENTALS 2% OESIGN TEMPERATURES DO NOT EXCEED <br />47dC IN IHE UNITED STATES (PALM SPRINGS. CA IS 44,1OC) FOR LESS THAN 9 <br />CURRENT{ARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUII AT <br />LEAST O 5' ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47"C OR LESS (ALL OF UNITED STATES). <br />a) 12 AWG. 90"C CONDUCTORS ARE GENERALLY ACCEPTAAIE FOR MODULES <br />WITH lsc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE, <br />b) 1O AWG. gOC CONDUCTORS ARE GENERALLY ACCEPTAALE FOR MODULES <br />wlTH lsc OF 9.6 AMPS OR LESS WH€N PROT€CTEO 8Y A I'AMP OR SMALLER <br />FUSE <br />F <br />a- <br />d. <br />aa <br />a- <br />F <br />z <br />a- <br />o <br />ia <br />a-