10196830 - Permit
PBA
>
Building
>
Permits
>
B
>
Brook St
>
2822 W Brook St
>
10196830 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2021 12:01:34 PM
Creation date
6/2/2021 12:01:33 PM
Metadata
Fields
Template:
Permit
Permit Number
10196830
Full Address
2822 W Brook St
Permit ID
242916
Master ID Number
2018-144217
Project Name
Miscellaneous Counter1 Permit
Street Number
002822
Street Direction
W
Street Name
Brook
Street Suffix
St
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Building
Applied Date
6/21/2018
Issued Date
6/21/2018
Finalized Date
8/28/2018
Flood Zone
X-0602320256J
Description of Work
Install roof mounted pv panels. Per Residential Photovoltaic Checklist.
Nature of Work
Solar
Document Relationships
10196830 - Plan
(Plan)
Path:
\Building\Plans\B\Brook St\2822 W Brook St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXPEDITED PERJVTIT PROCESS FOR SMALL-SCALE PV SYSTEMS. STANDARD STRING SYSTEM <br />The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations <br />are simple, needing only a basic review and when an installation is more complex. lt is likely that 50 % -75% of all residential <br />systems will comply with these simple criteria. For projects that fail to meet the simple crileria, resolution s[eps have been <br />suggested to provide as a path to permit approval. <br />Requireil Inlonnation Jor Pet'mit : <br />t. Site plan showing location of major components on the property. This drawing need not be exacdy to scale, but it <br />should represent relative locarion of components at site (see supplied example site plan). PV arrays on dwellings <br />with a 3'perimeter space at ridge and sides may not need separale fire service review. <br />2 Electrical diagram showing PV array configuration, wiring system, overcurrent protecrion, inverter, disconnects, <br />required signs, and ac connection to building (see supplied standard electrical diagram). <br />3. Specification sheers and installation manuals (if available) for all manuFactured componenrs including, but not <br />limited ro, PV modules. inverter(s), combiner box. disconnects, and mounting system. <br />Step 'l : Structural Review of PV Array Mounting System <br />Is the array to be mounted on a dehned, permitted roof structure?ves E Ilo <br />I.f No due to non-compliant rooJ or a ground mount, submit completed worhsheet.for the structure WKSI <br />Roo.f Infofination: <br />Yes, Compl Is the roofrng type lightweight (Yes = composilion, lighlweight masonry, metal, etc. .) <br />If No, submit completed worksheet for rooJ structure WfiSl (No = heavy masonry, slate, etc.. .) <br />2. Does the roof have a single roof coveringt Elyes nno <br />If No, submit completed urorksheet jor roof structure wKSl . <br />3. Provide method and type of wearherproohng roof penetrations (e.9. flashing, caulk)Chem Curb <br />M ount ing Sy st em lnformat ion : <br />neered producr designed ro mount PV modules with no more than an 18" gap <br />benearh the module frames?Yes ! trto <br />If No, provide detuib of stuctural attachment certiied by q design professionq.l. <br />2. For manufactured mounting systems, hll out information on the mounring system below <br />stem Manufacturer Hoowho Product Name and Mode 14 Q.Peak-G4.1 305 <br />b. Total Weight of PV Mod ules and Rails 1245 bs <br />,.44 <br />1. Is the mounting structure an en <br />a Mounting Sy <br />c. Total Number of Attachment Poin <br />weighr per ArEchmenr Poinr (b + c) 28 lbs (if greater lhan 45 lbs, see WKS I )d <br />e nches (see product manual forMaximum Spacing Between Attachment Points on a Rail 72 <br />maximum spacing allowed based on maximum design wind speed) <br />Total Surface Area of PV Modules (square fee 395 frlf <br />3Distributed Weighr of PV Module on Roof (b + l)lbs/fa <br />IJ distributed weight of the PV system is greater than 5 lbs/fe, see wRSl . <br />Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) <br />In order for a PV system to be considered for an expedited permit process, the following must apply: <br />l. PV modules, utility-interacrive inverters, and combiner boxes are identiEed for use in PV systems. <br />2. The PV array is composed of 4 series strings or less per inverter <br />3. The total inverter capacity has a conrinuous ac power output 13,440 WaIts or less <br />4. The ac interconnection point is on the load side of service disconnecting means (690.64(8)). <br />5. One of the standard electrical diagrams (El.l. El.la, El.lb, or El.lc) can be used to accurately represent the PV <br />system. lnteractive PDF diagrams are available at www.solarabcs.org/permifting. <br />Fill out the standard electical diagram completely. A guide to the electrical diegram is provided to help the applicsnt <br />understand eqch blsnk to jll in. If the electrical system is more complex than the standard electical diagram con efJectively <br />communicate, provide an alternative diagram with awropritte detail. <br />2 ExpEDtrED PERM|T PRocEss FoR PV SysrEMS
The URL can be used to link to this page
Your browser does not support the video tag.