Laserfiche WebLink
*-SNTA <br />Ai.{AJffi <br />Planning & Building Agency <br />Building Satety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M.19) <br />Santa Ana, CA 92702 <br />(714) 647-s800 <br />www.santa-ana.otg <br />RESIDENTIAL <br />PHOTOVOLTATC <br />CHECKLIST <br />soL-0'1 cBc 2013 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall complete al! sections, answer lhe ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />1526 W 12TH ST, SANTA ANA, CA 92703 <br />conlraclor company Name: SOUTHWEST SUN SOLAR, INC <br />contractor License Number: 1004667 <br />YES NO Are the following applicable to the proposed project? <br />minimum I I' x '17" <br />Project Address: <br />8D <br />Eltr <br />Etr <br />MN <br />e mu <br />size. lf answerino NO anv of the oueslions. Dlan check shall be required. <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.1 1 of the California Fire Code, and is this shown on the roof ptan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV anay be fiush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />U/ill the PV system weigh maximum 4 pounds per squate feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to 10" maximum between <br />lhe undeBide of modules and the surface of the roof? <br />Will the PV system be installed withoul using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizonlal anchor spacing of 6 feet <br />and is this maximum horizonlal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed wilh a minimum of 2-1l2 inch <br />embedment into roof rafters (with pre-drilted holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL ihe structural pages of the plans WET stamped and signed by a California <br />licensed professional engineer? (including project speciilc site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturefs PV support information.) <br />4 <br />2 <br />3 <br />o <br />7 <br />I <br />atratr <br />atr <br />tsB <br />10 AU <br />I certify under penalty of periury under th€ laws of the State of California th <br />pdns x2ms. TRANG CONG PHAlvl <br />phone Number: 714 582 3909 <br />Signature <br />Date: <br />Ema it Address: PERIVIT@SOUTHWESTSUNSOLAR.COIV <br />Rev A11712015 <br />t! <br />above is trus: