My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
401 N Bush St
PBA
>
Building
>
Permits
>
B
>
Bush St
>
401 N Bush St
>
Misc.
>
401 N Bush St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2023 11:22:33 AM
Creation date
11/2/2023 11:22:32 AM
Metadata
Fields
Template:
Misc. Permit
Full Address
401 N Bush St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
P.C. SUBMISSION 02/23/2018 <br />Project Number: 16-242 <br />No.Issue Date <br />20 <br />1 <br /> <br />E <br />A <br />S <br />T <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />AP <br />A <br />R <br />T <br />M <br />E <br />N <br />T <br />S <br />20 <br />1 <br /> <br />E <br />A <br />S <br />T <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Revisions <br />2/ <br />2 <br />2 <br />/ <br />2 <br />0 <br />1 <br />8 <br /> <br />9 <br />: <br />3 <br />9 <br />: <br />2 <br />7 <br /> <br />A <br />M <br /> <br /> <br /> <br /> <br /> <br /> <br />P: <br />\ <br />2 <br />0 <br />1 <br />6 <br />\ <br />1 <br />6 <br />2 <br />4 <br />2 <br />_ <br />2 <br />0 <br />1 <br /> <br />E <br />. <br /> <br />F <br />o <br />u <br />r <br />t <br />h <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />\ <br />C <br />a <br />d <br />\ <br />S <br />h <br />e <br />e <br />t <br />s <br />\ <br />A <br />1 <br />. <br />0 <br />2 <br /> <br />L <br />E <br />V <br />E <br />L <br /> <br />2 <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />. <br />d <br />w <br />g <br />S <br />& <br /> <br />A <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />I <br />E <br />S <br />12 <br />9 <br /> <br />W <br />. <br /> <br />W <br />I <br />L <br />S <br />O <br />N <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />1 <br />0 <br />0 <br />CO <br />S <br />T <br />A <br /> <br />M <br />E <br />S <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />2 <br />3 <br />2 <br />(A) - CONCRETE <br />(B) - CMU <br />(C) - METAL STUD <br />(D) - WOOD <br />1.REFER TO SHEET A0.05 FOR GRAPHIC SYMBOLS AND ABBREVIATIONS. <br />2.REFER TO SHEET A0.10 FOR GENERAL NOTES. <br />3.REFER TO SHEETS "WALL TYPES" FOR WALL TYPE DETAILS. <br />4.REFER TO SHEETS "WINDOW SCHEDULE AND TYPES" AND "STOREFRONT SCHEDULE AND <br />TYPES" FOR WINDOW AND STOREFRONT TYPES AND GLAZING INFORMATION. <br />5.REFER TO SHEET "DOOR SCHEDULE AND TYPES" FOR DOOR SIZES AND TYPES. <br />6.REFER TO LANDSCAPE DRAWINGS FOR COLORS, FINISHES, THICKNESS, REINFORCING, AND <br />CONTROL / EXPANSION JOINTS OF WALKS AND HARDSCAPE AREAS. <br />7.REFER TO INTERIOR DESIGN DRAWINGS FOR FINISH MATERIAL SPECIFICATIONS. <br />8.PROVIDE FURRED WALLS AS REQUIRED FOR ALL UTILITY AND DRAIN LINES THAT EXTEND UP <br />THE INTERIOR WALL SURFACE. <br />9.ALL STRUCTURAL INFORMATION SHOWN ON THIS SHEET IS FOR REFERENCE ONLY. FOR ALL <br />FRAMING REFER T STRUCTURAL DRAWINGS PREPARED BY THE STRUCTURAL ENGINEER. G.C. <br />TO VERIFY ANY DISCREPANCIES WITH THE ARCHITECT PRIOR TO BEGINNING WORK. <br />10.DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, OR FACE OF MASONRY, UNLESS <br />OTHERWISE NOTED. <br />11.PROVIDE 2A-10BC FIRE EXTINGUISHER IN LOCATIONS AS REQUIRED BY FIRE DEPARTMENT. SEE <br />DETAILS 20 & 30 / A9.11. PROVIDE SIGN, APPROVED BY THE FIRE DEPARTMENT, REQ'D. TO <br />INDICATE THE LOCATION OF THE FIRE EXTINGUISHER. <br />12.APPROVED SET OF PANS FOR BUILDING, FIRE SPRINKLER, FIRE ALARM, ETC. SHALL BE ON THE <br />JOB SITE DURING CONSTRUCTION AND NO INSPECTIONS WILL BE MADE WITHOUT COMPLIANCE <br />WITH THE ABOVE PROVISION. <br />13.ALL ILLUMINATED EXIT SIGNS SHOWN SHALL BE CLEARLY VISIBLE AND NOT OBSTRUCTED BY <br />PIPES, MECHANICAL DUCTWORK, EQUIP. ETC. G.C. TO PROVIDE PENDANT EXTENSIONS AT ALL <br />CEILING HUNG EXIT SIGNS AS REQ.D PER 201 CBC SECTION 1011. <br />14.PROVIDE ADDITIONAL LAYERS OF 5/8" TYPE 'X' GYP. BOARD AT 1-2 HOUR WALL TRANSITIONS, <br />AND INTERIOR SHEAR WALL LOCATIONS, AS NECESSARY TO PROVIDE CONTINUOUS FLUSH <br />WALL SURFACE. <br />15.PROVIDE 1/2" 4'x8' PLYWOOD AT REAR WALL OF ALL IDF CLOSETS FOR EQUIPMENT <br />ATTACHMENT. <br />16.INSTALL ADDITIONAL LAYER OF GYPSUM BOARD AT ENDS OF PLYWOOD SHEAR PANELS TO <br />PROVIDE A SMOOTH UN-INTERUPTED WALL FINISH. <br />SHEET NOTES <br />GRAPHIC LEGEND <br />WALL TYPE <br />FURRING WIDTH <br />WALL STRUCTURAL FRAME WIDTH <br />WALL TYPE TAG <br />XX <br />XX <br />RM # <br />RM NAME <br />REF SHT <br />(N) INFILL FLOOR <br />SEE STRUCT. DWGS. FOR ADDITIONAL INFORMATION <br />ROOM NAME & NUMBER TAG <br />DOOR TAG <br />WINDOW TAG <br />REFERENCE DATUM AT EXISTING WALL FOR <br />VERIFIED-IN-FIELD MEASUREMENTS <br />KEYNOTES <br />A REVISED GRADING AND (N) RAMP AT ACCESSIBLE LOBBY ENTRANCE <br />SEE SHEET A5.01 FOR ADDITIONAL INFORMATION <br />EXISTING (E) 1 HR FIRE BARRIER (CBC 2016 - SECT. 707) <br />NEW (N) 2 HR FIRE BARRIER (CBC 2016 - SECT. 707) <br />NEW (N) 1 HR FIRE BARRIER (CBC 2016 - SECT. 707) <br />PARTITIONS: <br />NEW (N) NON RATED PARTITION <br />EXISTING (E) NON RATED PARTITION <br />EXISTING (E) 2 HR FIRE BARRIER (CBC 2016 - SECT. 707) <br />(E) EXISTING BUILDING / FLOOR TO REMAIN <br />N.I.C. PROTECT IN PLACE DURING CONSTRUCTION <br />NEW (N) PLUMBING PARTITION <br />(N) MECH. ACCESS AREA <br />LADDER TO ACCESS MECH. / STORAGE SHELF <br />PROPOSED MECHANICAL DUCTWORK <br />SEE MECH. DWGS. FOR ADDTL. INFORMATION <br />(N) MECHANICAL PLATFORM <br />MECHANICAL FAU CLOSET <br />SEE MECH. DWGS. FOR ADDTL. INFORMATION <br />(N) TPO JOHN MANSVILLE DECK COATING <br />SEE PRODUCT SPEC. FOR ADDTL. INFORMATION <br />B (N) INFILL FLOOR <br />SEE STRUCT. DWGS. FOR ADDITIONAL INFORMATION <br />C (N) EXTERIOR BALCONY <br />SEE STRUCT. DWGS. FOR ADDITIONAL INFORMATION <br />D (E) METAL + FABRIC AWNINGS <br />PROTECT IN PLACE DURING DEMOLITION AND CONSTRUCTION <br />E <br />(N) METAL AWNINGS TO MATCH EXISTINGF <br />(N) LANDSCAPE PLANTERSG <br />TRASH CHUTE <br />SEE SHEET A5.01 FOR ADDITIONAL INFORMATIONH <br />(N) SKYLIGHT <br />SEE ROOF PLAN FOR ADDITIONAL INFORMATIONI <br />LINE OF GARAGE DOOR CLEARACE ABOVEJ <br />(N) DRAIN ROUTING TIED INTO (E) & (N) ROOF DRAIN CONNECTIONS <br />PROTECT IN PLACE DURING DEMOLITION & CONSTRUCTION WORK <br />K (N) LINEN / (N) PANTRY <br />SEE SHEET A6.21 FOR ADDITIONAL INFORMATION <br />L (E) METAL COLUMN TO REMAIN <br />PROTECT IN PLACE DURING DEMOLITION & CONSTRUCTION WORK <br />M (E) FIRE RISER TO REMAIN <br />PROTECT IN PLACE DURING DEMOLTION & CONSTRUCTION WORK <br />N (E) FIRE DEPARTMENT CONNECTION <br />PROTECT IN PLACE DURING DEMOLTION & CONSTRUCTION WORK <br />O (E) ROOF ACCESS LADDER TO REMAIN <br />P STACKED WASHER / DRYER WITH 30" x 48" ACCESSIBLE CLEAR SPACE <br />3'-2" x 3'-2" MIN. INTERIOR CLEARANCE, SEE PRODUCT MANF. SPEC. FOR ADDTL. INFO. <br />Q (E) RATED GREASE TRAP ACCESS DOOR <br />PROTECT IN PLACE DURING DEMOLITION & CONSTRUCTION WORK <br />LIGHT FIXTURE <br />-0 / 0A0 <br />R (N) FLUSH MOUNTED ELECTRICAL CABINET OR EQUIPMENT AS NOTED BY <br />ELECTRICAL CONSULTANT <br />FLOOR PLAN - <br />LEVEL 2 <br />A1.021LEVEL 1 FLOOR PLAN <br />1/8" = 1'-0"N
The URL can be used to link to this page
Your browser does not support the video tag.