Laserfiche WebLink
E>, ICC EVALUATIONc-3 SERVICE Most Widely Accepted and Trusted <br />ICC-ES Evaluation Report ESR-2144 Supplement <br />Issued August 1, 2011 <br />This report is subject to renewal in one year. <br />www.icc-es.ora I (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® <br />DIVISION: 07 00 00-THERMAL AND MOISTURE PROTECTION <br />Section: 07 32 13-Clay Roof Tiles <br />REPORT HOLDER: <br />MARUHACHI CERAMICS OF AMERICA, INC., <br />dba MCA CLAY ROOF TILES <br />1985 SAMPSON AVENUE <br />CORONA, CALIFORNIA 92879 <br />(951) 736-9590 <br />www.mcatlle.com <br />EVALUATION SUBJECT: <br />MCA CLAY ROOF TILES: ONE-PIECE MISSION, 10-INCH STRAIGHT BARREL MISSION, 8-INCH STRAIGHT BARREL <br />MISSION, CORONA TAPERED MISSION, CLASSIC TAPERED MISSION, ROMAN PAN, MF108 INTERLOCKING FLAT, <br />IMPROVED-S, ORIENTAL, AND CLASSIC "S" MISSION TILES <br />1.0 EVALUATION SCOPE <br />Compliance with the following codes: <br />• 2007 Florida Building Code-Building <br />• 2007 Florida Building Code-Residential <br />Properties evaluated: <br />• Fire classification <br />• Roof covering <br />• Wind uplift resistance <br />2.0 PURPOSE OF THIS SUPPLEMENT <br />This supplement is issued to indicate that the clay roof tiles described in Sections 2.0 through 7.0 of the master report <br />ESR-2144 comply with the 2007 Florida Su#ding Code-Residential, when designed and installed in accordance with the <br />master evaluation report, with this additional condition: The clay roof tiles must be installed in accordance with the <br />recommendations of the FRSA/TRI 07320 Installation Manual. <br />Use of the clay roof tiles described in the master evaluation report for compliance with the High-Velocity Hurricane Zone <br />provisions of the 2007 Florida Building Code-Building, and the 2007 Florida Building Code-Residential has not been <br />evaluated, and is outside the scope of this supplement. <br />For products falling under Florida Rule 98-3, verification that the report holdefs quality assurance entity approved by the <br />Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity <br />- (or the code official when the report holder does not possess an approval by the Commission). <br />This supplement expires concurrently with the master report reissued August 1, 2011. <br />ICC-ES Emlitation Reports ore not to be constmed os representing aesthetics or any other attributes not specifically addressed. nor are they to bc constnted <br />as an endorsement ofthe subject of he report or a recommendationfor its tue. There is no warranty by ICC Embtation Senice, LLC. express or implied, as <br />to any finding orother matter in thls report. or as to any product covered by the report <br />Copyright© 2011 Page 1 of 1