My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10177791_2102 N. TUSTIN - Plan
PBA
>
Building
>
Plans
>
T
>
Tustin Ave
>
2102 N Tustin Ave
>
10177791_2102 N. TUSTIN - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2026 3:33:39 AM
Creation date
10/25/2020 5:13:30 PM
Metadata
Fields
Template:
Plan
Permit Number
10177791
Full Address
2102 N Tustin Ave
Street Number
2102
Street Direction
N
Street Name
Tustin
Street Suffix
Ave
Fully Linked
True
Document Relationships
10177791 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tustin Ave\2102 N Tustin Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
AXIAL ENGINEERING GROUP, INC. <br />7251 OWENSMOUTH AVENUE, SUITE 4 <br />CANOGA PARK, CA 91303 <br />(818) 902-0200 <br />DESIGN CRITERIA <br />CODE:2010 CALIFORNIA BUILDING CODE <br />TIMBER:Douglas Fir Larch (per grading rules 16) <br />2 x 4 and 4 x 4 - Grade No. 2 <br />2 x 6 and larger -Grade No. 2 <br />4 x 6 and larger -Grade No. 2 <br />(Beams and Stringers) <br />PLYWOOD:PS-1-95 <br />Per APA Standard <br />GLUE LAMINATED:24F-V4 DF/DF - Simple support beams <br />24F-V8 DF/DF - Cantilever beams <br />Per AITC Standards <br />STRUCTURAL STEEL: ASTM A36 Steel <br />Pipe Columns and Tube Steel <br />Per AISC Standards <br />Grade B Type E or Type S, ASTM A501 <br />WELDING:AWS-E70XX, Per American Welding Society Standards <br />CONCRETE:Per ACI 318 specifications <br />Conventional Foundations.fc = 3,000 psi <br />Pre-cast concrete fc = 3,000 psi <br />Columns fc = 3,000 psi <br />Structural Slab fc = 3,000 psi <br />(note: special inspection required for fc >2,500 psi) <br />MASONRY:Hollow Concrete Units (CMU, Concrete Blocks) <br />ASTM C-90, ASTM and UBC Standards <br />Type N units, Type S Mortar, 2,000 psi grout <br />fm = 1,350 psi (partially grouted) Fm = 225 psi <br />fm= 1,500 psi (solid grouted) Fm = 225 psi <br />REINFORCING STEEL: ASTM A615 Per CRSI Standards <br />#4 and Smaller -Grade 40 <br />#5 and Larger -Grade 60 <br />SOIL Soils Report by:Harrington Geotechnical Engineering, Inc. <br />Allowable Soils Bearing Pressure:1500 PSF <br />.... <br />..............
The URL can be used to link to this page
Your browser does not support the video tag.