Laserfiche WebLink
73 SIGN COMPONENTS MANUAL (SAM)November 14,2012 <br />Class 2 LED Modules, Cat. No. J LB-20111, JLB-24111, JLB-32111, J LB-42111, J LB-48111. <br />1. The suitability of these comporients must be evaluated in the end product. <br />2. These LED modules are rated 5 VDC, and have been evaluated for use only with Listed or Recognized Class 2 power sources. <br />Additional evaluations shall be considered when used with power supplies that exceed Class 2 limit. <br />3. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply and 60 watts per Class 2 circuit. <br />5. These products are not required to be enclosed or protected from weather in the end-product and are suitable for use in dry, <br />damp and wet with supply sources rated at 5 VDC or less. <br />6. These modules are not suitable for use as part of the sign body or enclosure. <br />7. The suitability of the mounting and connecting means shall be determined in the end product. <br />JKL COMPONENTS CORP <br />13343 PAXTON ST <br />E339601 <br />PACOIMA, CA 91331 <br />Class 2 LED Modules, designated as ZAF-336-24, ZAF-486-24, ZAF-636-24, ZAF-936-24, ZAF-1236-24; may be followed by <br />additional suffixes for color temperature. <br />1. These products are only suitable for connection to a Class 2 power source rated 24 Volt DC or less. <br />2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy <br />limited circuit and is rated greater than 24V DC. <br />3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or <br />output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 24 Volts DC or less. <br />5. These products are not required to be endosed or protected from the weather in the end product. <br />6. These products may be secured in place in the end product by any means <br />LED Illumination Modules, ZM-4047-CW, ZM-1957-CW, ZM-1543-R. <br />1. Each Class 2 LED Modules is only suitable for connection to a Class 2 power source, max. 24 Volt dc or less. <br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 <br />voltage and energy limits. <br />3. Class 2 LED modules, rated max. 12 Watts per LED unit or less. When units are connected to a Class 2 drcuit, they are not <br />to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at max. 24 Volt DC or less. <br />5. These products are not required to be endosed or protected from the weather in the end product. <br />Class 2 LED Modules, Cat. No. ZWF-)000<-XX, where XXXX-XX will be replaced with alpha-numeric digits that indicated <br />length and color. <br />1. These Class 2 LED modules are only suitable for connection to a Class 2 powersource, rated 15 Volt or less. <br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 <br />voltage and energy limits. <br />3. These Class 2 LED modules are rated max. 2 Watts per LED module. When these units are connected to a Class 2 drcuit, <br />they are not to draw a total wattage of greater than the secondary or output rating of the Class.2 supply. <br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at max. 15 Volts or less. <br />5. These products are not required to be endosed or protected from the weather in the end product. <br />JOHNSON WALKER & ASSOCIATES L LC, DBA IMPERIAL PLASTICS MFG E225580 <br />SUITE 1 <br />244 S COURT ST <br />LAPEER, MI 48446 <br />Aluminum Reinforced Sign Face Trim, designated Signatrim. <br />1. Acceptable for use in dry, damp and wet locations. <br />2. Water exclusion must be determined in the end product. <br />3. Minimum 5 cm (2 in.) spacing from heat producing components required. <br />4. The specified solvents are continuously applied to edge of acrylic or polycarbonate sign face. Additional spedfied adhesives <br />may be applied for the final bond. <br />Sign Face Generic Material Solvent Final Bond Adhesive Sign Trim Generic Material <br />11 <br />AMethyl Methacrylate (Acrylic) Methylene Chloride Methylene Chloride Cellulose Acetate Butyrate <br />Methyl Methacrylate (Acrylic) Weld-ON #4 Weld-ON # 16 Cellulose Acetate Butyrate <br />Methylene Chloride <br />m'Polycarbonate Transco Transco Cellulose Acetate Butyrate <br />Channel Bond Channel Bond <br />5. The suitability. of the securement or "fit" of this trip cap shall be determined in the end product. Screws or solvents are <br />considered acceptable for permanent mounting. <br />JS LED TECHNOLOGY CORP, DBA JS LED POWER INC E308859 <br />1318 MAINE AVE <br />BALDWIN PARK, CA 91706 <br />Class 2 LED·Modules, Cat. No. JE-00ABCD-XY-EZseries, where A, B, C, D, E, Z, X any Y may be any alphanumeric characters. <br />1. These products are only suitable for connection to a Class 2 power source rated 12 Volt AC/DC or less. <br />2. These products are each rated max. 24 watts per module. When units are connected to a Class 2 circuit, they are not to <br />draw a total wattage of greater than the secondary or output rating of the Class 2 supply. <br />1