Laserfiche WebLink
HMA-60NUseries <br />SPECIFICATION <br />MODEL <br />DCVOLTAGE <br />RATED CURRENT <br />CURRENT RANGE <br />RATED POWER <br />RIPPLE&NOISE(max.)Note.2 <br />OUTPUT VOLTAGETOLERANCE Note.3 <br />LINE REGULATION <br />LOAD REGULATION <br />SETUP„ RISE TIME Note.6 <br />Features : <br />• Constant voltage design <br />• Universal AC input / Full range <br />• Fully encapsulated with IP67 level <br />\Vithstand 300VAC surge input for 5 seconds <br />Protections: Short circuit / Overload / Over voltage <br />Fully isolated plastic case <br />Cooling by free air convection <br />ULI310 Class 2 UL879 UL8750 power unit, pass LPS <br />100% full load burn-in test <br />Low cost, high reliability <br />Suitable for LED lighting and moving sign applications <br />2 years warranty <br />LPS IP67 c'AI. C € <br />H&1.4-60NU-RX <br />12V <br />5A <br />0-5A <br />60W <br />120<nVP-p <br />£5.0% <br />*1.0% <br />*2.0% <br />500ms, 20ms / 230VAC 500ms, 20ms /ll 5VAC (for 5-36V); 500ms, 30ms / 2]OVAC 500ms, ]Oms /Il 5VAC <br />at full load(for 48V) <br />Bt <br />HOLD UP TIME(Typ.)cOins/230VAC 16ms/115VAC at full load <br />VOLTAGE RANGE Note.4 100-127VAC <br />FREQUENCY RANGE 47 - 63Hz <br />EFFICIENCY (Typ·)95% <br />INPUT <br />AC CURRENT 1.2A/115VAC 1.4/230VAC <br />INRUSH CURRENT(inax.)COLD STAR 30A/1 15VAC 60A/230VAC <br />LEAK.AGE CURRENT 0.25mA /240VAC <br />OVER CURRENT 110- 150% <br />PROTEC-Protection type: Hiccup mode, reovers automatically after fault condition is removed <br />TION OVER VOLTAGE B.8 - 16.2V <br />Protection type: Shut down 0/p voltage. re-power on to recover <br />WORKING TEal P -30-+70%{Refer to output load derating curve) <br />WORKING HUMIDITY 20-90% RH-nondensing <br />ENVIRON- <br />SHORAGETEMP,HUMIDITY 40-+80 C,10-95% RH <br />MENT <br />TEMP.CONEFFICIENT 10.03%/'C (0-50'C) <br />VIBRATION 10-500Hz, 20 10min,/1 cycle, period for 60min. each long X. Y. Z axes. <br />SAFETY STANDARDS ULI 310 Class 2(except for LPV-60-5), CAN/CSAC22.2 No. 223-M91(except for LPV-60,LPV ·6048), IP67 <br />approved ; design refer toTUV EN60950-1, EN61347-2- 13 <br />WITHSTAND VOLTAGE 1/P-O/P:3KVAC <br />SAFETY &ISOLATION RESISTANCE 1/P-OR:>1004[ Ohms / 500VDC / 25 C / 70% RH <br />DIC EMI CONDITION &Compliance to EN55022(CISPR22)Class B <br />RADIATION <br />HARMONIC CURRENT Compliance 10 ClassA, ENADOM-JENG 1 00{B -2 <br />EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,3,11 ; ENV 50204. EN55024, light industry level, crileriaA <br />ATBF 732Khrs min.MIL-HDBK-1 1 71 (25'C) <br />OTHERS DIMENSION !64*41.3*32.6mmt[*W*H) <br />PACKING 0.327Kg; 50pcs/16.35Kg <br />1. All parameters NOT specially nientioned are measured at 230VAC input, rated load and 25 of anibient temperature. <br />2. Ripple & noise are measured at 'OMHz of landuidth by using a I 2 ' tuisted pair-wire terminated nith a 0. luf & 47uf parallel capacitor. <br />3. Tolerance : includes set up tolerance, line regulation and load regulation. <br />4. Deraling may be needed under low input voltage. Please check the staxic characteristics for more details. <br />NOTE <br />5. Thepower supply is considered as a component thot Mll be operated in combination uith final equipment. Since EMC performance will be affected by <br />/he <br />complete installation, the final equipmen, manufacturers mus re-qualify EMC Directive on ihe complete ins"llation again. <br />6. Le,igth of setup lime is measured at first cold stan. Turning ON/OFF the power supply may lead to increase o f the setup time <br />LOAD(%)