Laserfiche WebLink
SOLARMOUNT Technical Datasheets :i:UNIRAC <br />A HILTI GROUP COMPANY <br />SolarMount Beam Connection Hardware <br />SolarMount L-Foot <br />Part No. 304000C, 304000D <br />L-Foot material: One of the following extruded aluminum alloys: 6005- <br />T5, 6105-T5, 6061-T6 <br />Ultimate tensile: 38ksi, Yield: 35 ksi <br />Finish: Clear or Dark Anodized <br />L-Foot weight: varies based on height: -0.215 lbs (98g) <br />Allowable and design loads are valid when components are <br />assembled with SolarMount series beams according to authorized <br />UNIRAC documents <br />For the beam to L.Foot connection: <br />· Assemble with one ASTM F593 %"-16 hex head screw and one <br />ASTM F594 %"serrated flange nut <br />· Use anti-seize and tighten to 30 ft-lbs of torque <br />Resistance factors and safety factors are determined according to part <br />1 section 9 of the 2005 Aluminum Design Manual and third-party test <br />results from an IAS accredited laboratory <br />A1 NOTE: Loads are given for the L-Foot to beam connection only; be <br />--X sure to check load limits for standoff, lag screw, or other <br />attachment method <br />- 6 <br />- 1 <br />- lot <br />JX SLOT FOR <br />36 -"f ' - 1 <br />, 1 <br />1 <br />2.01 - <br />Dimensions specified in inches unless noted <br />Applied Load Average Safety Design Resistance <br />Direction Ultimate Allowable Load Factor,Load Factor, <br />lbs (N)lbs (N)FS lbs (N) ® <br />Sliding, Zi 1766 (7856)755 (3356)2.34 1141 (5077)0.646 <br />Tension, Y+1859 (8269)707 (3144)2.63 1069 (4755)0.575 <br />Compression, Y- 3258 (14492)1325 (5893)2.46 2004 (8913)0.615 <br />Traverse, Xi 486 (2162)213 (949)2.28 323 (1436)0.664 <br />0 <br />e