WIRE/CONDUIT SCHEDULE MODULE SPECIFICATION <br />TAG DESCRIPTION <br />1 ARRAY TO JUNCTION BOX <br />1 ARRAY TO JUNCTION BOX <br />1 ARRAY TO JUNCTION BOX <br />2 JUNCTION BOX TO AC DISCONNECT <br />3 AC DISCONNECT TO REVENUE GRADE METER <br />4 REVENUE GRADE METER TO MSP <br />5 BARE COPPER WIRE <br />6 EQUIPMENT GROUND <br />CONDUIT <br />CONDUCTOR TYPE/SIZE <br />SIZE/TYPE <br />#10 AWG USE-2 FREE AIR <br />#10 AWG USE-2 FREE AIR <br />#10 AWG USE-2 FREE AIR <br />#10 AWG THWN-2 i" EMT <br />#10 AWG THWN-2 i" EMT <br />#10 AWG THWN-2 1" EMT <br />#8 AWG SOLID FREE AIR <br />#8 AWG THWN-2 <br />NOTES MODELNO.SOLAR MAX ZHM230P <br />PEAK POWER 230W <br />BLACK - Ll <br />RATED VOLTAGE (Vmp)30.1V <br />RED - L2 RATED CURRENT (Imp)7.67A <br />BLUE -NEUTRAL OPEN CIRCUIT VOLTAGE (Voc)37.14V <br />SHORT CIRCUIT CURRENT (Isc)8.45A <br />INVERTER SPECIFICATION <br />INVERTER MAKE ENPHASE <br />INVERTER MODEL M215 <br />MAX. DC VOLT RATING 45V <br />MAX. AC APPARENT POWER 215W <br />NOMINAL AC VOLTAGE 240V <br />MAX AC CURRENT 0.9A <br />GENERAL ELECTRICAL NOTES: <br />1. EQUIPMENT USED SHALL BE NEW, UNLESS OTHERWISE NOTED. <br />2. EQUIPMENT SHALL BE INSTALLED PROVIDING ADEQUATE PHYSICAL <br />WORKING SPACE AROUND THE EQUIPMENT AND SHALL COMPLY WITH NEC <br />3. COPPER CONDUCTORS SHALL BE USED AND SHALL HAVE INSULATION <br />RATING 600V, 90°C, UNLESS OTHERWISE NOTED. <br />4. CONDUCTORS SHALL BE SIZED IN ACCORDANCE TO NEC. CONDUCTORS <br />AMPACITY SHALL BE DE-RATED FOR TEMPERATURE INCREASE, CONDUIT <br />FILL AND VOLTAGE DROP. <br />5. ALL CONDUCTORS, EXCEPT USE-2, SHALL BE INSTALLED IN APPROVED <br />CONDUITS OR RACEWAY. CONDUITS SHALL BE ADEQUATELY SUPPORTED <br />AS PER NEC. <br />6. RACKING AND MODULES ARE GROUNDED VIA A·CONTINUOUS #10 AWG <br />COPPER CONDUCTOR, GROUNDING CLOPS, GROUNDING LUGS AND/OR <br />BONDING JUMPERS. <br />7. LOAD SIDE INTER-CONNECTION SHALL COMPLY WITH NEC <br />8. SMOKE ALARM AND CARBON MONOXIDE DETECTORS SHALL BE LOCATED <br />AS REQD PER SEC. R314 & R315 OF THE CALIFORNIA RESIDENTIAL CODE <br />(CRC) <br />9. ALL EQUIPMENT SHALL BE LISTED FOR THE APPLICATION, UL 1703 FOR <br />MODULES, UL 1741 FOR INVERTERS <br />i <br />i" EMT <br />J-BOX <br />ARRAY DETAILS 3f <br />NO. OF MODULE PER STRING <br />9NO. OF STRINGS <br />ARRAY WATTS AT STC <br />/E <br />MAX. VOLTAGE »*t <br />/ d <br />E <br />CO <br />0 <br />,101!CROINVERTER MICROINVERTER MICROINVERTER '\\4, <br />1 1 • LA <br />11 U <br />[*71 AC 1 AC/ 1 <br />DC 1/9CI UTILITY <br />G G G Bl-DIRECTIONAL <br />ELECTRIC METER <br />-8+ 8 8 <br />(9 <br />.. MAIN SERVICE PANEL ON <br />-2 <br />100A, 240VAC, 1 PH 6 C)U.1 <L<.*-4 MODULE,3 ZGH:4Z 90<LO <br />ZZ96 *91<2)-3 Mca 64 Es<u, <br />100A O t=EWg <br />AC DISCONNECT REVENUE GRADE 05 31-<r <br />O- m -cos240VAC, 30A ENERGY METER <br />NEMA 3R, UL LISTED <br />TITLE: <br />SINGLE LINE <br />DIAGRAM <br />14 <br />1 <br />3.22KW <br />240V AB NAA¥80 <br />2 3 <br />20A <br />11 <br />V <br />- 4615k ---1/ <br />4 <br />6 GND <br />N L2 Ll'TI,flolo _JOB NO: 20492X <br />_L EXISTING DATE: 07/03/13 <br />- GROUND <br />PV 3