Laserfiche WebLink
127 SIGN COMPONENTS MANUAL (SAM)June 19, 2013 <br />7. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />Class 2 power supplies, Model 701495. <br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of four Class 2 <br />outputs. <br />2. These power supplies are only suitable for use in dry, damp and wet locations. <br />3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />Class 2 power LED Lighting Strip, 701912-QQXXYYZZZ series, where QQ represents length, XX represents the LED color <br />temperature, YY represents configuration and ZZZ represents the LED drive current. <br />1. These products are only suitable for connection to a Class 2 power source, rated 24VDC. <br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage <br />and energy limits and which is rated greater than 24VDC. <br />3. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated class 2. <br />5. These products are not required to be enclosed or protected from the weather in the end product. <br />6. These products may be secured in place in the end product by any means available. <br />7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall <br />be considered. <br />Class 2 "Dimming Control Knob" potentiometer, Model 701843. <br />1. These products are only suitable for connection to the output of a UL Listed or Recognized Class 2 power supply rated max 12 <br />VDC. <br />2. These products are suitable for use in dry and damp locations. <br />3. These products are suitable for factory wiring only. <br />4. These products are 1 Kohm potentiometers intended for connection to max 12 VDC Class 2 power supply that drops the voltage <br />to a 0-10 V signal to feed into the PWM dimmer. <br />Class 2 LED Modules, Cat. No. 701960-XXYYYZ Series, where XX, YYY, and Z may be replaced with any alphanumeric <br />character or blank. <br />1. These products are suitable for use in dry, damp and wet locations and supplied only with a Class 2 power source rated 24 Volt <br />DC or less. <br />2. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply. <br />3. These products are not required to be enclosed or protected from the weather in the end product. <br />4. These products may be secured in place in the end product by any means available. <br />SPARTECH PLASTICS <br />3454 N DETROIT ST <br />E202184 <br />WARSAW, IN 46580 <br />Rigid sign enclosure systems, designated SunGard, Sungard Plus, PC-2000, DuraGard and PC-2000 Plus. <br />1. These materials are acceptable for applications of sign enclosures, sign bodies, and decorative parts. For enclosure <br />applications, these materials may be located no closer than 0.8 mm to any uninsulated live part. <br />2. The materials, SunGard, PC-2000,or DuraGard and PC-2000 Plus, have a use temperature of 80C. If a heat producing <br />Component such as electrode, transformer or ballast is located within 1 inch of the material, a temperature test should be <br />conducted in the end product. <br />3. The material, SunGard Plus, has a rated temperature index (RTI) of 105°C, and therefore, is suitable for direct contact with and <br />mounting to heat producing component such as transformers, power supplies, and ballasts in the end product. <br />4. Marking - The following markings or equivalent shall be provided. Markings A and B below shall be marked anywhere where <br />readily visible during servicing. <br />A. "Do not attempt to repair or service a damaged sign face. For servicing of this sign, contact ."(Blank to be <br />replaced by Applicant's Company name, City and State.) <br />B. "Replace only with , Type ." (Blanks to be replaced by Applicant's Company name and material Type or <br />designation.) <br />5. The SunGard and SunGard Plus are suitable for use as an enclosure of an indoor or outdoor sign and has been evaluated for <br />UV exposure. The PC-2000,or DuraGard or PC-2000 Plus are suitable only for use as an enclosure for indoor signs. <br />6. All materials must be a minimum of 0.10 in. (2.54 mm) thick to comply as a sign enclosure. All testing should be repeated if the <br />thickness of the sheet is reduced to less than 0.10 in. <br />7. All materials have been investigated for and comply with the termination of conduit, electrode housings or the like. <br />8. All materials have been approved for component support. <br />9. The suitability of the securement system for the SunGard and Sungard Plus materials to prevent the entrance of water, which <br />may contact live parts within a sign in outdoor sign applications, shall be determined. <br />10. When the material is relied upon for the mounting of the sign and/or sign components, the material shall be subjected to the <br />mounting means test in the end product. <br />11. A marking shall be provided inside the sign indicating that servicing or replacement of the sign face material must be done by <br />the company which sold the sign. <br />12. Only one side of the Sungard or SunGard Plus plastic sheets are UV coated. Therefore, the UV coated side shall be placed <br />such that it is the exterior surface of the sign. <br />13. Testing for exposure to live parts was conducted on the non-UV *coated side of the Sungard and Sungard Plus plastics. Thus, <br />the non-UV coated side shall be the only side exposed to live parts. <br />14. The mounting system must secure the sign face to the enclosure in such a way that the edges of the sign face are not exposed <br />to the interior of the sign. This may be accomplished with channels, flanges or other suitable mechanical means. <br />Rigid non-enclosure sign face, systems for use in electric signs, designated: R59(1). May be followed by up to five numbers <br />and/or letters to indicate color.