My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1006 N Lowell St - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Lowell St
>
1006 N Lowell St
>
1006 N Lowell St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 8:01:20 AM
Creation date
5/30/2025 8:00:25 AM
Metadata
Fields
Template:
Plan
Permit Number
20177009
101111512
Full Address
1006 N Lowell St
Document Relationships
101111512 - Permit
(Permit - Plan)
Path:
\Building\Permits\L\Lowell St\1006 N Lowell St
20177009 - Permit
(Permit - Plan)
Path:
\Building\Permits\L\Lowell St\1006 N Lowell St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SCOPE OF WORK: <br />INSTALL (13) SOLARIA POWER XT-400R-PM SOLAR ELECTRIC MODULES AND <br />(13) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY <br />COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, <br />JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL <br />(1) SOLAREDGE SE6000H-US INVERTER WITH INTEGRATED DC DISCONNECT, <br />(1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. <br />HOMEOWNER: MATTHIAS KNUTH <br />PH: 310.972.9067 <br />ADDRESS: 1006 N. LOWELL STREET <br />SANTA ANA, CA 92703 <br />DATE: 6/27/22DATE: 6/27/22 <br />SUN SOLAR US INC. <br />16755 VON KARMAN AVENUE #200 <br />IRVINE, CA 92606 <br />PH: 949.242.0088 RONALD RHODES B, C10 - 975072 <br />VICINITY MAP <br />KNUTH <br />RESIDENCE <br />SHEET INDEX: <br />SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK <br />SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL <br />SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL <br />SHEET 4 CALCULATIONS, SIGNS <br />ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, <br />STRUCTURAL REPORT <br />NTS <br />SHEET <br />NOTICE: <br />ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE <br />WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. <br />1 OF 4 <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />(13) SOLARIA POWER XT-400R-PM <br />PEAK POWER = 400 W <br />MAX OPERATING CURRENT = 9.41 A <br />MAX OPERATING VOLTAGE = 42.2 V <br />OPEN CIRCUIT VOLTAGE = 51.1 V <br />SHORT CIRCUIT CURRENT = 9.82 A <br />MAX SERIES FUSE RATING = 20 A <br />TEMP. COEFF. OF Voc = -0.29%/°C <br />DIMENSIONS = 64.7" X 47.4" X 1.6" <br />WEIGHT = 46.0 LBS <br />GENERAL NOTES: <br />1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 <br />CEC. <br />2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY <br />HAS BEEN NOTIFIED. <br />3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. <br />4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. <br />5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE <br />UL 1741 COMPLIANT. <br />6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER. <br />7. CONDUCTORS ARE 90° C RATED COPPER WIRE. <br />8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT <br />RESISTANT. <br />9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED <br />IN A METAL RACEWAY. <br />10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE <br />PROTECTED IN CONDUIT. <br />11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED <br />FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES <br />AND RAILS AND SECURED IN PLACE. <br />12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING <br />CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS. <br />14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE <br />INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE <br />WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. <br />17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS. <br />74378PV <br />INVERTER/DC DISCONNECT: (1) SOLAREDGE SE6000H-US <br />MAX DC INPUT VOLTAGE = 480 V <br />NOMINAL DC INPUT VOLTAGE = 380 V <br />MAX DC INPUT CURRENT = 16.5 A <br />DC DISCONNECT MAX INPUT CURRENT = 30.0 A <br />NUMBER OF DC INPUTS = 2 <br />RATED AC POWER = 6000 W <br />AC VOLTAGE = 240 V <br />MAX AC OUTPUT CURRENT = 25.0 A <br />NEMA 4X ENCLOSURE <br />DIMENSIONS = 17.7" X 14.6" X 6.8" <br />WEIGHT = 26 LBS <br />PHOTOVOLTAIC SOLAR PROJECT INFORMATION: <br />SYSTEM SIZE: 5.200 kW (DC) <br />MODULES: <br />MODULE ADD-ON:(13) SOLAREDGE S440 <br />DC POWER OPTIMIZERS <br />MAX DC INPUT VOLTAGE = 60 V <br />OPERATING VOLTAGE RANGE = 8 V - 60 V <br />MAX DC INPUT CURRENT = 14.5 A <br />MAX DC OUTPUT CURRENT = 15 A <br />DC OUTPUT VOLTAGE = 380 V <br />MAX POWER PER STRING <br />(CONTROLLED BY INVERTER) = 5700 W <br />NEMA 6P ENCLOSURE <br />DIMENSIONS = 5.1" X 6.0" X 1.2" <br />WEIGHT = 1.5 LB <br />ARRAY: INSTALLED WEIGHT = 2.8 PSF <br />ROOF COVERAGE = 280 SF, <br />ARRAYS COVER 9% OF TOTAL ROOF AREA <br />MOUNTING HARDWARE: GRIPRAC STANDARD RAIL <br />GRIPRAC FLASHING KIT ATTACHMENTS <br />5 16" STAINLESS STEEL LAG BOLTS @ <br />72" OC OR LESS WITH A MINIMUM OF <br />21 2" PENETRATION INTO ROOF RAFTERS <br />EXISTING ROOF INFO: 1 STORY, ASPHALT SHINGLE <br />2 X 4 RAFTERS @ 24" OC <br />BLDG # 101111512 <br />ELEC # 20177009 <br />ISSUED: 8/10/2022 <br />1006 N Lowell Street <br />08/11/22
The URL can be used to link to this page
Your browser does not support the video tag.