Laserfiche WebLink
SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />GUERRA <br />RESIDENCE <br />1 035 <br />W WALNUT ST <br />SANTA ANA, CA <br />92703 <br />CONTRACTOR <br />SIGNATURE OF LICENSE HOLDER <br />1 0.800 DC kW <br />SYSTEM <br />9.730 CEC AC RATING <br />MICRO INVERTER SYSTEM <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN <br />DESIGN BY: LG/SC <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />08-08-22 <br />3857 FOOTHILL BLVD <br />GLENDALE, CA, 91214 <br />EMAIL: INFO@MAGICSOLAR.NET <br />PHONE: (818) - 388 - 5478 <br />MAGIC SUN POWER INC <br />dba MAGIC SOLAR ELECTRIC <br />LIC# 999485 <br />B & C1 0 <br />PROJECT NAME <br />E1 <br />ELECTRICAL <br />LINE DIAGRAM <br />WIRE/CONDUIT SCHEDULE <br />NOTE: TERMINATE LUGS AT 75°. WIRING/CONDUIT RACEWAY WILL BE MIN 7/8'' ABOVE THE ROOF <br />TAG DESCRIPTION CONDUCTOR TYPE/SIZE/QUANTITY CONDUIT <br />SIZE/TYPE <br />AC1 ARRAY TO JBOX <br />6 #12 AWG ENPHASE AC CABLE <br />FREE AIR <br />1 #6 AWG GND-BARE COPPER <br />AC2 JBOX TO AC COMBINER <br />6 #10 AWG 3L1 & 3L2 THWN-2 <br />3/4" EMT <br />1 #8 AWG GND THWN-2 <br />AC3 AC COMBINER TO AC <br />DISCONNECT <br />3 #6 AWG L1, L2 & N THWN-2 <br />3/4" EMT <br />1 #8 AWG GND THWN-2 <br />AC4 AC DISCONNECT TO <br />MAIN SERVICE PANEL <br />3 #6 AWG L1, L2 & N THWN-2 <br />3/4" EMT <br />1 #8 AWG GND THWN-2 <br />(N) 27 - Q.PEAK DUO BLK ML-G10+400 <br />HANWHA Q.CELL MODULES WITH <br />(N) 27 - IQ8PLUS-72-2-US (240V) [SI1] <br />ENPHASE MICRO INVERTERS <br />(N)50A <br />PV OCPD <br />EXISTING <br />200A MAIN SERVICE PANEL <br />240V, 1P, 3W; CENTER FED <br />N <br />G <br />M (N) 175A <br />MCB <br />SCE <br />METER# <br />222012- <br />787231 <br />EARTH <br />GROUND <br />(N) JBOX <br />nema 3r AC1 <br />A - 9 <br />(N) ENPHASE IQ <br />COMBINER BOX <br />(X-IQ-AM1-240-4) <br />*NO ADDITIONAL LOADS* <br />(N)20A <br />IQ <br />ENVOY <br />PCB <br />N <br />G <br />CT <br />AC2 <br />AC4 <br />(N)15A B - 9 <br />(N)20A <br />(N) 60 AC <br />DISCONNECT <br />G <br />N <br />AC3 <br />(N)20A <br />C - 9 <br />INTERCONNECTION COMPLIANCE PER 705 CODE <br />SUM OF CIRCUITS WITH 125% <br />MAX AC OUTPUT (AMPS) TOTAL # OF <br />MICROS <br />TOTAL MAX AC <br />OUTPUT 125% RESULT (AMPS)OCPD SIZE <br />1.21 27 32.67 1.25 40.84 50A <br />SERVICE PANEL CALCULATIONS WITH 120% <br />BUS RATING SIZE MUTIPLIER (120%) RESULT MAIN <br />BREAKER <br />INVERTER AC <br />OUTPUT+125%RESULT <br />200 1.20 240 175 40.84 215.84 <br />240.00 >/= 215.84 = OK <br />NOTE: <br />705.12(B)(2)(3) BUSBARS <br />(B) WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER <br />SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 <br />PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE <br />OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE <br />AMPACITY OF THE BUSBAR. THE BUSBAR SHALL BE SIZED FOR THE LOADS CONNECTED IN <br />ACCORDANCE WITH ARTICLE 220. A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE <br />DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE POWER SOURCE THAT <br />DISPLAYS THE FOLLOWING OR EQUIVALENT WORDING: <br />WARNING: POWER SOURCE OUTPUT CONNECTION — DO NOT RELOCATE THIS OVERCURRENT <br />DEVICE. <br />THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 110.21(B). <br />BRANCH CIRCUIT CALCULATION <br />CIRCUIT MAX AC OUTPUT <br />(AMPS) <br /># OF <br />MODULES RESULT (AMPS) 125%RESULT <br />(AMPS)ocpd size <br />A 1.21 9 10.89 1.25 13.61 20A <br />B 1.21 9 10.89 1.25 13.61 20A <br />C 1.21 9 10.89 1.25 13.61 20A <br />NOTE: <br />THE ENPHASE IQ MICROINVERTER SYSTEM USES A NEW AND IMPROVED CABLING SYSTEM. THE Q CABLE IS DG <br />TYPE AND CONTAINS ONLY TWO #12 AWG LINE CONDUCTORS. THE Q CABLE MALE CONNECTORS PLUG <br />DIRECTLY INTO THE IQ MICROS, WHOSE DOUBLE INSULATION RATING REQUIRES NO NEUTRAL OR GROUND <br />CONDUCTORS <br />PV MODULE MAXIMUM DC VOLTAGE <br />MAX NUMBER OF MODULES PER INVERTER × {VOC + [(TL-25) × (Ǻ× VOC)/100]} = VOLTS <br />MODULE <br />VOC <br />MODULES PER <br />INVERTER <br />VOC TEMP <br />COEFFICIENT <br />%/°C <br />Tl -25 ( β x VOC)(TL-25) × (β × <br />VOC)/100 VOLTS <br />45.30 1.00 -0.26 -35 -11.78 4.12 49.42 <br />49.42V < 60V = OK <br />NOTE: MAXIMUM DC VOLTAGE SHALL NOT EXCEED INVERTER MANUFACTURER'S MAXIMUM INPUT VOLTAGE <br />MODULE SPECIFICATION <br />MANUFACTURER HANHWA Q.CELLS <br />MODEL NO.Q.PEAK DUO BLK ML-G10+400 <br />PEAK POWER 400 W <br />MPP VOLTAGE (VMPP)37.13 V <br />MPP CURRENT (IMPP)10.77 A <br />OPEN CIRCUIT VOLTAGE (VOC)45.30 V <br />SHORT CIRCUIT CURRENT (ISC)11.14 A <br />INVERTER SPECIFICATION <br />INVERTER MAKE ENPHASE ENERGY <br />INVERTER MODEL NO.IQ8PLUS-72-2-US (240V) [SI1] <br />MAX INPUT DC VOLTAGE 60V <br />MAX CONT. OUTPUT POWER 290 VA <br />PEAK OUTPUT POWER 300 VA <br />NOMIMAL AC VOLTAGE/RANGE 240V/ 211-264V <br />MAX AC CURRENT 1.21A <br />NOTE: <br />1) PV BREAKER MUST BE INSTALLED <br />AT THE FARTHEST, OPPOSITE END <br />OF MAIN BREAKER <br />2) SOLAR GROUND TYING INTO THE <br />UFER GROUND POINT <br />1035 W Walnut St <br />10/24/22