My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1035 W Walnut St - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Walnut St
>
1035 W Walnut St
>
1035 W Walnut St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 8:01:21 AM
Creation date
5/30/2025 8:00:26 AM
Metadata
Fields
Template:
Plan
Permit Number
20177702
101112441
Full Address
1035 W Walnut St
Document Relationships
101112441 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Walnut St\1035 W Walnut St
20177702 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Walnut St\1035 W Walnut St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />GUERRA <br />RESIDENCE <br />1 035 <br />W WALNUT ST <br />SANTA ANA, CA <br />92703 <br />CONTRACTOR <br />SIGNATURE OF LICENSE HOLDER <br />1 0.800 DC kW <br />SYSTEM <br />9.730 CEC AC RATING <br />MICRO INVERTER SYSTEM <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN <br />DESIGN BY: LG/SC <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />08-08-22 <br />3857 FOOTHILL BLVD <br />GLENDALE, CA, 91214 <br />EMAIL: INFO@MAGICSOLAR.NET <br />PHONE: (818) - 388 - 5478 <br />MAGIC SUN POWER INC <br />dba MAGIC SOLAR ELECTRIC <br />LIC# 999485 <br />B & C10 <br />PROJECT NAME <br />E2 <br />ELECTRICAL <br />CALCULATIONS <br />LOCATION INFORMATION <br />NEC TABLE 310.15 (B)(2)(a)-TEMP CORRECTION FACTORS <br />WIRE TERMINATIONS AT 75° AMPACITY <br />HIGH TEMP 34 °C <br />LOW TEMP 2 °C <br />VOLTAGE CORRECTION FACTOR -TABLE <br />690.7(A)1.10 <br />ROOF TEMP + 33°-IF RACEWAY CONDUIT IS LESS <br />THAN 7/8" ABOVE ROOF 67 °C <br />TEMP CORRECTION FACTOR (ABOVE ROOF)0.65 <br />TEMP CORRECTION FACTOR (INSIDE CONDUIT) 0.96 <br />AC CONDUCTOR AMPACITY CALCULATIONS - SUM OF CIRCUITS <br />BETWEEN AC COMBINER TO MAIN SERVICE PANEL <br />A AMBIENT TEMPERATURE ADJUSTMENT <br />EXPOSED CONDUIT 34 CELSIUS <br />TEMPERATURE CORRECTION FACTOR 0.96 CEC TABLE 310.15 (B)(2)(A) <br /># OF CURRENT CARRYING CONDUCTORS 2 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) <br />CONDUIT FILL CORRECTION 1.00 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) <br />CEC TABLE 310.15 (B)(3)(A) <br />CIRCUIT CONDUCTOR SIZE #6 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) <br />CIRCUIT CONDUCTOR AMPACITY @ 90° 75 AMPS CEC TABLE 310.15 (B)(16) <br />INVERTER'S MAXIMUM AC OUTPUT CURRENT 1.21 AMPS INVERTER MANUFACTURER SPECIFICATIONS <br />B REQUIRED AC CONDUCTOR AMPACITY 40.84 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY = 1.25 X AC MODULE OUTPUT CURRENT X TOTAL # OF AC MODULES <br />C DERATED AMPACITY OF CIRCUIT CONDUCTORS 72.00 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY <br />CEC TABLE 310.15 (B)(2)(A) <br />NOTE: "C" MUST BE GREATER THAN "B" 72.00A > 40.84A = OK <br />AC CONDUCTOR AMPACITY CALCULATIONS <br />JBOX/COMBINER BOX TO AC COMBINER - PER RANCH CIRCUIT <br />A EXPECTED WIRE TEMPERATURE (FREE AIR)34 CELSIUS <br />310.15(B)(3)(C) RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS. WHERE RACEWAYS OR CABLES <br />ARE EXPOSED TO DIRECT SUNLIGHT ON OR ABOVE ROOFTOPS, RACEWAYS OR CABLES SHALL BE INSTALLED A <br />MINIMUM DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR CABLE OF 23 MM (7∕8 IN.). <br />B ADD 33°C FOR CONDUITS EXPOSED TO <br />SUNLIGHT ON OR ABOVE ROOF 67 CELSIUS WIRING/CONDUIT RACEWAY WILL BE EQUAL TO 7/8'' OR MORE ABOVE THE ROOFTOP PER CEC 310.15(B)(3)(c) <br />TEMPERATURE CORRECTION FACTOR <br />CEC TABLE 310.15 (B)(2)(A)0.96 <br />C # OF CURRENT CARRYING CONDUCTORS 6 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) <br />D CONDUIT FILL CORRECTION 0.80 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) <br />CEC TABLE 310.15 (B)(3)(A) <br />E CIRCUIT CONDUCTOR SIZE #10 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) <br />F CIRCUIT CONDUCTOR AMPACITY@75°35 AMPS CEC TABLE 310.15 (B)(16) <br />G REQUIRED CIRCUIT CONDUCTOR AMPACITY 14.74 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY = 1.25 X AC MODULE OUTPUT CURRENT X # OF AC MODULES PER <br />CIRCUIT <br />H DERATED AMPACITY OF CIRCUIT CONDUCTOR 26.88 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY <br />CEC TABLE 310.15 (B)(2)(A) <br />NOTE: "H" MUST BE LARGER THAN "G" 26.88A > 14.74A = OK - CIRCUIT WITH 9 MODULES <br />INVERTER SPECIFICATION <br />INVERTER MAKE ENPHASE ENERGY <br />INVERTER MODEL NO. IQ8PLUS-72-2-US (240V) [SI1] <br />MAX INPUT DC VOLTAGE 60V <br />MAX CONT. OUTPUT POWER 290 VA <br />RECOMMENDED INPUT POWER 235W - 440W <br />NOMIMAL AC VOLTAGE/RANGE 240V/ 211-264V <br />MAX AC CURRENT 1.21A <br />MODULE SPECIFICATION <br />MANUFACTURER HANHWA Q.CELLS <br />MODEL NO. Q.PEAK DUO BLK ML-G10+400 <br />PEAK POWER 400 W <br />MPP VOLTAGE (VMPP) 37.13 V <br />MPP CURRENT (IMPP) 10.77 A <br />OPEN CIRCUIT VOLTAGE (VOC) 45.30 V <br />SHORT CIRCUIT CURRENT (ISC) 11.14 A <br />1035 W Walnut St <br />10/24/22
The URL can be used to link to this page
Your browser does not support the video tag.