Laserfiche WebLink
HOMEOWNER: DENNIS HOANG <br />PH: 714.588.4468 <br />ADDRESS: 1202 S. KAREN AVENUE <br />SANTA ANA, CA 92704 <br />DATE: 5/2/22DATE: 5/2/22 <br />(&262/$5 86$ <br />(/(&75,&$///& <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />6&23(2):25. <br />INSTALL (17) SUNPOWER SPR-X22-360-E-AC SOLAR <br />ELECTRIC MODULES ON THE EXISTING 1ST STORY <br />COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING <br />HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND <br />GROUNDING. INSTALL (1) LOAD CENTER, (1) AC DISCONNECT, <br />AND INSTALL OCPD IN MAIN SERVICE PANEL. <br />SERVICE POINT & <br />UTILITY METERING <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING SOURCES <br />WITH DISCONNECTS AS SHOWN. <br />ADDRESS: 1202 S. KAREN AVENUE, SANTA ANA, CA 92704 <br />SOLAR ARRAY <br />(ON ROOF) <br />N <br />TO BE INSTALLED ON THE OUTSIDE COVER <br />OF THE MAIN SERVICE DISCONNECT: <br />6+((7 <br />127,&( <br />$1<&+$1*(67225 86(62)7+(6( <br />'2&80(176'5$:,1*6:,7+2877+( <br />:5,77(1&216(172)-(11,)(5 .(00(25 <br />6&277+$55,6$5(675,&7/<352+,%,7(' <br />2) <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />6<67(0 6,*1$*( <br />ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT <br />PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND <br />ATTACHED WITH WEATHERPROOF ADHESIVE OR <br />OTHER APPROVED METHOD. ALL LETTERS SHALL BE A <br />MINIMUM OF 3 8" HEIGHT AND ALL CAPITALIZED. <br />ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES <br />SHALL BE MARKED AT 10' MAX INTERVALS AND AT ALL <br />BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH <br />"WARNING: PHOTOVOLTAIC POWER SOURCE". <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE <br />AND LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />TO BE INSTALLED AT ALL SERVICEABLE PANELS <br />OR BOXES AND AT ALL DISCONNECTS: <br />RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM <br />RATED AC OUTPUT CURRENT = 27.84 A <br />NOMINAL OPERATING AC VOLTAGE = 240 V <br />TO BE INSTALLED NEXT TO THE <br />SOLAR BREAKER: <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TO BE INSTALLED ON THE FRONT OF THE <br />MAIN SERVICE DISCONNECT: <br />"SOLAR PV SYSTEM EQUIPPED WITH RAPID <br />SHUTDOWN" SHALL BE BLACK LETTERING <br />ON YELLOW BACKGROUND. THE <br />REMAINDER OF THE SIGN SHALL BE BLACK <br />LETTERING ON WHITE BACKGROUND. <br />6<67(0 &$/&8/$7,216 <br />NUMBER OF MODULES IN EACH CIRCUIT = 9 <br />MODULE MAX OUTPUT CURRENT = 1.31 A <br />(9) (1.31 A) (1.25) = 14.74 A [Ic], USE 15 A BREAKERS <br />TOTAL NUMBER OF MODULES = 17 <br />(17) (1.31 A) (1.25) = 27.84 A [I], USE 30 A BREAKER <br />MAIN SERVICE PANEL BUS RATING = 125 A <br />MAIN SERVICE PANEL MAIN OCPD = 100 A <br />100 A + 30 A SOLAR OCPD = 130 A <br />125 A BUS (1.2) = 150 A <br />130 A < 150 A, OK <br />:,5(&$/&8/$7,216 <br />FROM THE MODULES TO THE LOAD CENTER: <br />AMBIENT TEMPERATURE = 34°C <br />TEMPERATURE ADDER FOR CONDUIT NOT OFFSET FROM ROOF = 33°C <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />34°C + 33°C = 67°C = 0.58 <br />Ic = 14.96 A <br />14.96 A/0.58 = 25.79 A <br />NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT = 4 <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT FILL (4-6 CONDUCTORS IN <br />CONDUIT) = 0.80 <br />25.79 A/0.80 = 33.24 A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 33.24 A, USE 10 AWG THWN-2 COPPER <br />WIRE WITH AN AMPACITY OF 40 A <br />SELECT CONDUIT FOR (4) 10 AWG THWN-2 & (1) 10 AWG GROUND = 3 4" EMT CONDUIT <br />FROM THE LOAD CENTER TO THE MAIN SERVICE PANEL: <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />42°C = 0.96 <br />I = 27.84 A <br />27.84 A/0.96 = 29.00 A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 29.00 A, USE 10 AWG THWN-2 COPPER <br />WIRE WITH AN AMPACITY OF 40 A <br />SELECT CONDUIT FOR (3) 10 AWG THWN-2 & (1) 10 AWG GROUND = 3 4" EMT CONDUIT <br />1202 S Karen Ave <br />06/29/22