Laserfiche WebLink
STANDARD STRING SYSTEM SITE PLAN <br />EX <br />P <br />E <br />D <br />I <br />T <br />E <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />P <br />R <br />O <br />C <br />E <br />S <br />S <br /> <br />F <br />O <br />R <br /> <br />P <br />V <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />S <br />NOTES FOR ALL DRAWINGS: <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODE REFERENCES <br />SHOWN AS (NEC XXX.XX) <br />1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP 8.3°C <br />2.) highest continuous ambient temperature based on ashrae highest moth 2% dry bulb <br />temperature for ashrae location most similar to installation location. highest <br />continuous temperature 27°C <br />3.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURE DO NOT EXCEED 47%°C <br />IN THE UNITED STATES (PAL SPRINGS, CA IS 44.1°C) FOR LESS THAN 9 <br />CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST .05" <br />ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE FO 47°C OR LESS (ALL <br />OF THE UNITED STATES <br />A) 12 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH <br />ISC OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. <br />B) 10 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH <br />ISC OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. <br />NOTES FOR ARRAY CIRCUIT WIRING (GUIDE SECTION 6 AND 8 AND APPENDIX D): <br />1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET <br />THE REQUIREMENTS? YES NO N/A√ <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES NO N/A √ <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO <br />INVERTER OCPD AMPERE RATING. (SEE GUIDE SECTION 9) <br />5) TOTAL OF 1 INVERTER OCPD(S), ONE FOR EACH INVERTER. DOES TOTAL <br />SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN <br />690.64(B)(2)(A)? YES √ NO <br />NOTES FOR INVERTER CIRCUITS (GUIDE SECTION 8 AND 9): <br />PHOTOVOLTAIC POWER <br />SOURCE <br />RATED IMPP <br />CURRENT A <br />RATED IMPP <br />VOLTAGE V <br />MAX SYSTEM <br />VOLTAGE V <br />MAX CIRCUIT <br />CURRENT A <br />WARNING: ELECTRICAL SHOT <br />HAZARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />SOLAR PV SYSTEM AC POINT <br />OF CONNECTION <br />AC OUTPUT <br />CURRENT 60A <br />NOMINAL AC <br />VOLTAGE 240V <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />SIGN FOR INVERTER OCPD AND AC <br />DISCONNECT (IF USED) <br />SIGN FOR DC DISCONNECT <br />SIGNS-SEE GUIDE SECTION 7 <br />CONTRACTOR NAME. <br />ADDRESS AND PHONE: SITE PLAN FOR SMALL-SCALE, SINGLE-PHASE PV <br />SYSTEMS <br />SITE NAME: HECTOR GONZALEZ <br />SITE ADDRESS: 121 EAST ANAHURST PLACE <br />SYSTEM AC <br />SIZE:3.48 <br />DRAWN BY: MJ SIZE 3.48 FSCM NO: <br />DWG NO: <br />1 REV: 1 <br />CHECKED BY: MJ SCALE DATE: 44819 SHEET: 1 <br />PV MODULE RATING @ STC (GUIDE SECTION 5) <br />MODULE MAKE <br />(Aptos 370 watt) <br />DNA-120-MF26-370W <br />MODULE MODEL <br />(Aptos 370 watt) <br />DNA-120-MF26-370W <br />MAX PWER-POINT CURRENT (IMP) 20A <br />MAX POWER-POINT VOLTAGE (VMP) 1000V <br />OPEN-CIRCUIT CURRENT (VOC) 40.8V <br />SHORT-CIRCUIT CURRENT (ISC) 11.51A <br />MAX SERIES FUSE (ISC) 25A <br />MAXIMUM POWER (PMAX) 370 <br />MAX VOLTAGE (TYP 600VDC) 34.06V <br />VOC TEMP COEFF (mV/°C OR %/°C√) -0.29 <br />INVERTER RATING (GUIDE SECTION 4) <br />INVERTER MAKE SE3800-US <br />INVERTER MODEL SE3800-US <br />MAX DC VOLT RATING 480V <br />MAX POWER @ 40°C 93000W <br />NOMINAL AC VOLTAGE 240V <br />MAX AC CURRENT 25A <br />MAX OCPD RATING 25A <br />121 E Anahurst Pl <br />11/15/22