Laserfiche WebLink
PV-2.0REV: A <br />GARDOT, MARNI <br />1128 W RIVIERA DR <br />SANTA ANA, CA 92706 <br />APN # 5643-820-900 TEL #: ---- <br />CLIENT: <br />SIGNAGE <br />1611 POMONA RD.,STE# 206 <br />CORONA, CA 92878 <br />CSLB # 1043108 <br />PHONE 951.298.9007 <br />CONTRACTOR: <br />WEATHER RESISTANT PLASTIC PLACARD <br />PLACEMENT: MAIN PANEL (COVER) <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS AS SHOWN <br />CAUTION: <br />LABEL LOCATION: <br />INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT <br />(PER CODE: CEC690.13 & CEC 690.13) <br />SIGNAGE <br />LABEL LOCATION: <br />INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT <br />(PER CODE: CEC690.13 & CEC 690.13) <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION DO <br />NOT RELOCATE THIS OVERCURRENT DEVICE <br />CAUTION: SOLAR ELECTRIC <br />SYSTEM CONNECTED <br />CAUTION: SOLAR CIRCUIT <br /> WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />! <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />WARNING:PHOTOVOLTAIC <br />POWERSOURCE <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />WARNING- ElectricShockHazard <br />No user serviceable parts inside <br />Contact authorized servi ce provider for assistance <br />! <br />AC SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />LABEL LOCATION: <br />UTILITY DISCONNECT <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />(PER CODE: CEC 705.12(B)(3-4)) <br />LABEL LOCATION: <br />MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC/AC CONDUIT, RACEWAYS, <br />ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND <br />ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. <br />LABEL LOCATION: <br />PER CEC 705.12(B)(2)(3)(B) <br /> [OR (C) IF PANELBOARD IS RATED NOT LESS THAN SUM OF AMPERE <br />RATINGS OF ALL OVERCURRENT DEVICES SUPPLYING IT] <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO <br />WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT <br />ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, <br />PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH <br />SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) <br />LABEL LOCATION: <br />DC DISCONNECT, INVERTER <br />(PER CODE: CEC 690.13(B)) <br />[To be used when inverter is ungrounded] <br />LABEL LOCATION: <br />AC DISCONNECT, POINT OF <br />INTERCONNECTION <br />(PER CODE: CEC 690.53) <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL <br />LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, <br />PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN <br />DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) <br />INVERTER <br />LABEL LOCATION: <br />DC DISCONNECT, INVERTER <br />(PER CODE: CEC690.53) <br />LABEL LOCATION: <br />RAPID SHUTDOWN OR ON INVERTER IF RSD IS <br />INTEGRATED <br />CEC 690.56(C)(3) <br />RAPIDSHUTDOWNSWITCHFOR <br />SOLAR PVSYSTEM <br />LABEL LOCATION: <br />SERVICE DISCONNECTING MEANS <br />(PER CODE: CEC 690.56(C)(1)(A)) <br />SOLAR PV SYSTEM <br />EQUIPPED WITH RAPID <br />SHUTDOWN <br />TURN RAPID <br />SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION <br />TO <br />SHUTDOWN PV <br />SYSTEM AND <br />REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR <br />ELECTRIC <br />PV PANELS <br />1128 W RIVIERA DR <br />SANTA ANA, CA 92706 <br />LABEL LOCATION: <br />AC DISCONNECT, INVERTER, POINT OF INTERCONNECTION <br />(PER CODE: CEC 690.54) <br />MAXIMUM SYSTEM VOLTAGE (VOC) <br />MAXIMUM CIRCUIT CURRENT (ISC) <br />MAX RATED OUTPUT CURRENT OF <br />THE CHARGE CONTROLLER OR <br />DC-TO-DC CONVERTER <br />480 V <br />15 A <br />15 A <br />SIGNAGE REQUIREMENTS: <br />· RED BACKGROUND <br />· WHITE LETTERING <br />· MINIMUM 3/8" LETTER HEIGHT <br />· ALL CAPITAL LETTERS <br />· ARIAL OR SIMILAR FONT, NON-BOLD <br />· REFLECTIVE WEATHER RESISTANT <br />MATERIAL SUITABLE FOR THE <br />ENVIRONMENT (DURABLE ADHESIVE <br />MATERIALS MUST MEET THIS <br />REQUIREMENT) <br />ADHESIVE FASTENED SIGNS: <br />· THE LABEL SHALL BE SUITABLE FOR <br />THE ENVIRONMENT WHERE IT IS <br />INSTALLED. <br />· WHERE REQUIRED ELSEWHERE IN <br />THIS CODE, ALL FIELD APPLIED <br />LABELS, WARNINGS, AND MARKINGS <br />SHOULD COMPLY WITH ANSI Z535.4 <br />[CEC 110.21(B) FIELD MARKING]. <br />· ADHESIVE FASTENED SIGNS MAY BE <br />ACCEPTABLE IF PROPERLY <br />ADHERED. VINYL SIGNS SHALL BE <br />WEATHER RESISTANT <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED AC OPERATING CURRENT 16 AMPS <br />AC NOMINAL OPERATING VOLTAGE 240 VOLTS <br />MAIN PANEL <br />SOLAR <br />ARRAY <br />WARNING! <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE UNGROUNDED <br />AND MAY BE ENERGIZED <br />LABEL LOCATION: <br />J-BOX, DC DISCONNECT, INVERTER <br />(PER CODE: CEC 690.35(F)) <br />[To be used when inverter is ungrounded] <br />ELECTRIC SHOCK HAZARD <br />IF A GROUND FAULT IS INDICATED <br />NORMALLY GROUNDED CONDUCTORS <br />MAY BE UNGROUNDED AND ENERGIZED <br />LABEL LOCATION: <br />J-BOX, AC DISCONNECT, INVERTER <br />(PER CODE: CEC 690.35(F)) <br />[To be used when inverter is ungrounded] <br />WARNING ! <br />! <br />3/7/22 <br />INVERTER <br />1128 W Riviera Dr <br />05/31/22