Laserfiche WebLink
Project Information <br />Chris Baynes <br />1226 W River Ln, <br />Santa Ana, CA 92706 <br />Date: May 20, 2022 <br />SHEET INDEX <br />PV-1 Plot Plan <br />PV-2.1 Stringing <br />PV-2.2 Single line diagram <br />PV-3 Array Layout <br />PV-4 Signage <br />Sheet <br /> 5-13 Additional Information <br /> Data sheets, <br /> Certifications... <br />SOLAR SOURCE INC 2954 E 14TH <br />ST, LONG BEACH, CA 90804 LIC#: <br />925231, CLASS - C46, C10 Lisense <br />Date 03/31/2023 <br />(N) PV BREAKER <br />installed in slot <br />furthest from main breaker <br />#4 FACILITY <br />GROUND <br /> AMP <br />NON CENTER <br />MAIN BREAKER <br /> MAIN SERVICE PANEL 120/240V, <br /> SINGLE PHASE SERVICE <br /> MAIN PANEL BUS <br /> MAIN BREAKER <br />UTILITY <br />METER <br />70A <br />8' minimum embedment rod at 6' <br />from equipment ground conductor unless <br />existing ground is UFER. <br />225A <br />225A <br />200A <br />200A <br />Existing <br />Existing <br />ENPHASE IQ COMBINER 4 <br />SOLAR-ONLY SUB PANEL <br />125A BUS, 120/240 VAC <br />ENVOY <br />MONITORING <br />SYSTEM <br />15A <br />BREAKER <br />20A 2P PV <br />BREAKER <br />20A 2P PV <br />BREAKER <br />3/4" EMT CONDUIT <br />(3) #6 AWG THWN-2 Conductors <br />(1) #8 AWG THWN-2 Ground <br />20 <br />FEET <br />J BOX <br />NEMA 3R <br />WIRES EXPOSED TO FREE AIR UNDER ARRAY <br />Enphase Q-Cable <br />(2) #12 AWG Conductors <br />(1) #6 AWG Bare Copper Ground <br />BRANCH #1 <br />BRANCH #2 <br />BRANCH #3 <br />BRANCH #4 <br />3/4" EMT CONDUIT <br />(8) #10 AWG THWN-2 Conductors <br />(1) #8 AWG THWN-2 Ground <br />20A 2P PV <br />BREAKER <br />20A 2P PV <br />BREAKER <br />2 <br />FEET <br />IQ8M-72-2-US <br />Q.PEAK DUO BLK-G10+ 360 Q.PEAK DUO BLK-G10+ 360 <br />IQ8M-72-2-US <br />Q.PEAK DUO BLK-G10+ 360 <br />IQ8M-72-2-US <br />Q.PEAK DUO BLK-G10+ 360 <br />IQ8M-72-2-US <br />Q.PEAK DUO BLK-G10+ 360 <br />IQ8M-72-2-US <br />Q.PEAK DUO BLK-G10+ 360 <br />IQ8M-72-2-US <br />11 <br />11 <br />8 N/A <br />N/A <br />6 <br />PV-2.2 <br />SINGLE LINE <br />DIAGRAM <br />1)Equipment is "New" unless otherwise noted. <br />All PV system wires shall be protected against physical damage <br />2)Terminations shall be rated 75 degree <br />PV PANEL AND EQUIPMENT MODEL NUMBER,QUANTITY <br />B.CIRCUIT <br />#1 <br />B.CIRCUIT <br />#2 <br />B.CIRCUIT <br />#3 <br />B.CIRCUIT <br />#5 <br />B.CIRCUIT <br />#6 <br />B.CIRCUIT <br />#4 <br />(if applicable) <br />(if applicable) <br />(if applicable) <br />(if applicable) <br />(if applicable) <br />ADDITIONAL NOTES <br />1226 W River Ln - <br />2017666907/18/22